Literature DB >> 18404928

Iterative sorting for four-dimensional CT images based on internal anatomy motion.

Rongping Zeng1, Jeffrey A Fessler, James M Balter, Peter A Balter.   

Abstract

Current four-dimensional (4D) computed tomography (CT) imaging techniques using multislice CT scanners require retrospective sorting of the reconstructed two-dimensional (2D) CT images. Most existing sorting methods depend on externally monitored breathing signals recorded by extra instruments. External signals may not always accurately capture the breathing status and may lead to severe discontinuity artifacts in the sorted CT volumes. This article describes a method to find the temporal correspondences for the free-breathing multislice CT images acquired at different table positions based on internal anatomy movement. The algorithm iteratively sorts the CT images using estimated internal motion indices. It starts from two imperfect reference volumes obtained from the unsorted CT images; then, in each iteration, thorax motion is estimated from the reference volumes and the free-breathing CT images. Based on the estimated motion, the breathing indices as well as the reference volumes are refined and fed into the next iteration. The algorithm terminates when two successive iterations attain the same sorted reference volumes. In three out of five patient studies, our method attained comparable image quality with that using external breathing signals. For the other two patient studies, where the external signals poorly reflected the internal motion, the proposed method significantly improved the sorted 4D CT volumes, albeit with greater computation time.

Entities:  

Mesh:

Year:  2008        PMID: 18404928      PMCID: PMC2851165          DOI: 10.1118/1.2837286

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

Review 1.  A survey of medical image registration.

Authors:  J B Maintz; M A Viergever
Journal:  Med Image Anal       Date:  1998-03       Impact factor: 8.545

2.  Acquiring 4D thoracic CT scans using a multislice helical method.

Authors:  P J Keall; G Starkschall; H Shukla; K M Forster; V Ortiz; C W Stevens; S S Vedam; R George; T Guerrero; R Mohan
Journal:  Phys Med Biol       Date:  2004-05-21       Impact factor: 3.609

3.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT.

Authors:  Tinsu Pan; Ting-Yim Lee; Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2004-02       Impact factor: 4.071

4.  Respiratory correlated cone beam CT.

Authors:  Jan-Jakob Sonke; Lambert Zijp; Peter Remeijer; Marcel van Herk
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

5.  Respiratory motion estimation from slowly rotating x-ray projections: theory and simulation.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

6.  An algorithm for automatic determination of the respiratory phases in four-dimensional computed tomography.

Authors:  T Kleshneva; J Muzik; M Alber
Journal:  Phys Med Biol       Date:  2006-07-26       Impact factor: 3.609

7.  The correlation evaluation of a tumor tracking system using multiple external markers.

Authors:  Hui Yan; Fang-Fang Yin; Guo-Pei Zhu; Munther Ajlouni; Jae Ho Kim
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

8.  Lung deformation estimation and four-dimensional CT lung reconstruction.

Authors:  Sheng Xu; Russell H Taylor; Gabor Fichtinger; Kevin Cleary
Journal:  Acad Radiol       Date:  2006-09       Impact factor: 3.173

9.  Estimating 3-D respiratory motion from orbiting views by tomographic image registration.

Authors:  Rongping Zeng; Jeffrey A Fessler; James M Balter
Journal:  IEEE Trans Med Imaging       Date:  2007-02       Impact factor: 10.048

10.  Fast parametric elastic image registration.

Authors:  Jan Kybic; Michael Unser
Journal:  IEEE Trans Image Process       Date:  2003       Impact factor: 10.856

View more
  9 in total

1.  MRI-based motion correction of thoracic PET: initial comparison of acquisition protocols and correction strategies suitable for simultaneous PET/MRI systems.

Authors:  Nikolaos Dikaios; David Izquierdo-Garcia; Martin J Graves; Venkatesh Mani; Zahi A Fayad; Tim D Fryer
Journal:  Eur Radiol       Date:  2011-09-22       Impact factor: 5.315

2.  Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Authors:  Agung Hertanto; Qinghui Zhang; Yu-Chi Hu; Oleksandr Dzyubak; Andreas Rimner; Gig S Mageras
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

3.  Quality and accuracy of cone beam computed tomography gated by active breathing control.

Authors:  Bria P Thompson; Geoffrey D Hugo
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Characterization and identification of spatial artifacts during 4D-CT imaging.

Authors:  Dongfeng Han; John Bayouth; Sudershan Bhatia; Milan Sonka; Xiaodong Wu
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071

5.  Estimating the 4D respiratory lung motion by spatiotemporal registration and super-resolution image reconstruction.

Authors:  Guorong Wu; Qian Wang; Jun Lian; Dinggang Shen
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

6.  Estimating view parameters from random projections for Tomography using spherical MDS.

Authors:  Yi Fang; Sundar Murugappan; Karthik Ramani
Journal:  BMC Med Imaging       Date:  2010-06-18       Impact factor: 1.930

7.  Data-driven gated CT: An automated respiratory gating method to enable data-driven gated PET/CT.

Authors:  Tinsu Pan; M Allan Thomas; Dershan Luo
Journal:  Med Phys       Date:  2022-04-22       Impact factor: 4.506

8.  Respiratory motion correction of PET using MR-constrained PET-PET registration.

Authors:  Daniel R Balfour; Paul K Marsden; Irene Polycarpou; Christoph Kolbitsch; Andrew P King
Journal:  Biomed Eng Online       Date:  2015-09-18       Impact factor: 2.819

9.  Comparing approaches to correct for respiratory motion in NH3 PET-CT cardiac perfusion imaging.

Authors:  Paul J Schleyer; Michael J O'Doherty; Sally F Barrington; Geraint Morton; Paul K Marsden
Journal:  Nucl Med Commun       Date:  2013-12       Impact factor: 1.690

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.