Reduction of irregular breathing artifacts in respiration-correlated CT images using a respiratory motion model.

Agung Hertanto1, Qinghui Zhang, Yu-Chi Hu, Oleksandr Dzyubak, Andreas Rimner, Gig S Mageras.   

Abstract

PURPOSE: Respiration-correlated CT (RCCT) images produced with commonly used phase-based sorting of CT slices often exhibit discontinuity artifacts between CT slices, caused by cycle-to-cycle amplitude variations in respiration. Sorting based on the displacement of the respiratory signal yields slices at more consistent respiratory motion states and hence reduces artifacts, but missing image data (gaps) may occur. The authors report on the application of a respiratory motion model to produce an RCCT image set with reduced artifacts and without missing data.
METHODS: Input data consist of CT slices from a cine CT scan acquired while recording respiration by monitoring abdominal displacement. The model-based generation of RCCT images consists of four processing steps: (1) displacement-based sorting of CT slices to form volume images at 10 motion states over the cycle; (2) selection of a reference image without gaps and deformable registration between the reference image and each of the remaining images; (3) generation of the motion model by applying a principal component analysis to establish a relationship between displacement field and respiration signal at each motion state; (4) application of the motion model to deform the reference image into images at the 9 other motion states. Deformable image registration uses a modified fast free-form algorithm that excludes zero-intensity voxels, caused by missing data, from the image similarity term in the minimization function. In each iteration of the minimization, the displacement field in the gap regions is linearly interpolated from nearest neighbor nonzero intensity slices. Evaluation of the model-based RCCT examines three types of image sets: cine scans of a physical phantom programmed to move according to a patient respiratory signal, NURBS-based cardiac torso (NCAT) software phantom, and patient thoracic scans.
RESULTS: Comparison in physical motion phantom shows that object distortion caused by variable motion amplitude in phase-based sorting is visibly reduced with model-based RCCT. Comparison of model-based RCCT to original NCAT images as ground truth shows best agreement at motion states whose displacement-sorted images have no missing slices, with mean and maximum discrepancies in lung of 1 and 3 mm, respectively. Larger discrepancies correlate with motion states having a larger number of missing slices in the displacement-sorted images. Artifacts in patient images at different motion states are also reduced. Comparison with displacement-sorted patient images as a ground truth shows that the model-based images closely reproduce the ground truth geometry at different motion states.
CONCLUSIONS: Results in phantom and patient images indicate that the proposed method can produce RCCT image sets with reduced artifacts relative to phase-sorted images, without the gaps inherent in displacement-sorted images. The method requires a reference image at one motion state that has no missing data. Highly irregular breathing patterns can affect the method's performance, by introducing artifacts in the reference image (although reduced relative to phase-sorted images), or in decreased accuracy in the image prediction of motion states containing large regions of missing data.
© 2012 American Association of Physicists in Medicine.

Entities:  

Mesh:

Year:  2012        PMID: 22755692      PMCID: PMC3360690          DOI: 10.1118/1.4711802

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  24 in total

1.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion.

Authors:  Eike Rietzel; George T Y Chen; Noah C Choi; Christopher G Willet
Journal:  Int J Radiat Oncol Biol Phys       Date:  2005-04-01       Impact factor: 7.038

2.  Improving retrospective sorting of 4D computed tomography data.

Authors:  Eike Rietzel; George T Y Chen
Journal:  Med Phys       Date:  2006-02       Impact factor: 4.071

3.  Displacement-based binning of time-dependent computed tomography image data sets.

Authors:  Mathew J Fitzpatrick; George Starkschall; John A Antolak; Jun Fu; Himanshu Shukla; Paul J Keall; Paul Klahr; Radhe Mohan
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

4.  Image interpolation in 4D CT using a BSpline deformable registration model.

Authors:  Eduard Schreibmann; George T Y Chen; Lei Xing
Journal:  Int J Radiat Oncol Biol Phys       Date:  2006-02-28       Impact factor: 7.038

5.  Four-dimensional radiotherapy planning for DMLC-based respiratory motion tracking.

Authors:  Paul J Keall; Sarang Joshi; S Sastry Vedam; Jeffrey V Siebers; Vijaykumar R Kini; Radhe Mohan
Journal:  Med Phys       Date:  2005-04       Impact factor: 4.071

6.  Motion management with phase-adapted 4D-optimization.

Authors:  Omid Nohadani; Joao Seco; Thomas Bortfeld
Journal:  Phys Med Biol       Date:  2010-08-16       Impact factor: 3.609

7.  Retrospective analysis of artifacts in four-dimensional CT images of 50 abdominal and thoracic radiotherapy patients.

Authors:  Tokihiro Yamamoto; Ulrich Langner; Billy W Loo; John Shen; Paul J Keall
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008-09-25       Impact factor: 7.038

8.  4D CT sorting based on patient internal anatomy.

Authors:  Ruijiang Li; John H Lewis; Laura I Cerviño; Steve B Jiang
Journal:  Phys Med Biol       Date:  2009-07-22       Impact factor: 3.609

9.  Phase and amplitude binning for 4D-CT imaging.

Authors:  A F Abdelnour; S A Nehmeh; T Pan; J L Humm; P Vernon; H Schöder; K E Rosenzweig; G S Mageras; E Yorke; S M Larson; Y E Erdi
Journal:  Phys Med Biol       Date:  2007-05-18       Impact factor: 3.609

10.  A patient-specific respiratory model of anatomical motion for radiation treatment planning.

Authors:  Qinghui Zhang; Alex Pevsner; Agung Hertanto; Yu-Chi Hu; Kenneth E Rosenzweig; C Clifton Ling; Gig S Mageras
Journal:  Med Phys       Date:  2007-12       Impact factor: 4.071

View more
  18 in total

1.  3D fluoroscopic image estimation using patient-specific 4DCBCT-based motion models.

Authors:  S Dhou; M Hurwitz; P Mishra; W Cai; J Rottmann; R Li; C Williams; M Wagar; R Berbeco; D Ionascu; J H Lewis
Journal:  Phys Med Biol       Date:  2015-04-23       Impact factor: 3.609

2.  Prediction error and required internal margin provided for irregular respiratory movements: a phantom study.

Authors:  Nobuyoshi Fukumitsu; Haruko Numajiri; Kayoko Ohnishi; Masashi Mizumoto; Teruhito Aihara; Hitoshi Ishikawa; Toshiyuki Okumura; Koji Tsuboi; Toshiyuki Terunuma; Takeji Sakae; Hideyuki Sakurai
Journal:  Jpn J Radiol       Date:  2015-04-16       Impact factor: 2.374

3.  A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities.

Authors:  Amy Yuan; Jie Wei; Carl P Gaebler; Hailiang Huang; Devin Olek; Guang Li
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-09-03       Impact factor: 7.038

4.  Are fiducial markers useful surrogates when using respiratory gating to reduce motion of gastroesophageal junction tumors?

Authors:  Fenghong Liu; Shu Ng; Florence Huguet; Ellen D Yorke; Gikas S Mageras; Karyn A Goodman
Journal:  Acta Oncol       Date:  2016-05-06       Impact factor: 4.089

5.  Technical Note: Simulation of 4DCT tumor motion measurement errors.

Authors:  Tai H Dou; David H Thomas; Dylan O'Connell; Jeffrey D Bradley; James M Lamb; Daniel A Low
Journal:  Med Phys       Date:  2015-10       Impact factor: 4.071

6.  Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity.

Authors:  Guang Li; Marshall Caraveo; Jie Wei; Andreas Rimner; Abraham J Wu; Karyn A Goodman; Ellen Yorke
Journal:  Med Phys       Date:  2014-11       Impact factor: 4.071

7.  Data-driven respiratory motion compensation for four-dimensional cone-beam computed tomography (4D-CBCT) using groupwise deformable registration.

Authors:  Matthew J Riblett; Gary E Christensen; Elisabeth Weiss; Geoffrey D Hugo
Journal:  Med Phys       Date:  2018-09-18       Impact factor: 4.071

8.  Evaluation of 3D fluoroscopic image generation from a single planar treatment image on patient data with a modified XCAT phantom.

Authors:  Pankaj Mishra; Ruijiang Li; Sara St James; Raymond H Mak; Christopher L Williams; Yong Yue; Ross I Berbeco; John H Lewis
Journal:  Phys Med Biol       Date:  2013-01-21       Impact factor: 3.609

9.  Investigation of gated cone-beam CT to reduce respiratory motion blurring.

Authors:  Russell E Kincaid; Ellen D Yorke; Karyn A Goodman; Andreas Rimner; Abraham J Wu; Gig S Mageras
Journal:  Med Phys       Date:  2013-04       Impact factor: 4.071

10.  Dual-source CT in blunt trauma patients: elimination of diaphragmatic motion using high-pitch spiral technique.

Authors:  Teresa Liang; Patrick McLaughlin; Chesnal D Arepalli; Luck J Louis; Ana-Maria Bilawich; John Mayo; Savvas Nicolaou
Journal:  Emerg Radiol       Date:  2015-12-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.