Literature DB >> 18397022

Angle-dependent ultrasonic detection and imaging of brachytherapy seeds using singular spectrum analysis.

Jonathan Mamou1, Sarayu Ramachandran, Ernest J Feleppa.   

Abstract

Transrectal-ultrasound-guided brachytherapy uses small titanium-shelled radioactive seeds to locally treat prostate cancer. During the implantation procedure, needles inserted transperitoneally cause gland movement resulting in seed misplacement and suboptimal dosimetry. In a previous study, an algorithm based on singular spectrum analysis (SSA) applied to envelope-detected ultrasound signals was proposed to determine seed locations [J. Mamou and E. J. Feleppa, J. Acoust. Soc. Am. 121, 1790-1801 (2007)]. Successful implementation of the SSA algorithm could allow correcting dosimetry errors during the implantation procedure. The algorithm demonstrated promise when the seed orientation was parallel to the needle and normal to the ultrasound beam. In this present study, the algorithm was tested when the seed orientation deviated up to 22 degrees from normality. Experimental data from a seed in an ideal environment and in beef were collected with a single-element, spherically focused, 5 MHz transducer. Simulations were designed and evaluated with the algorithm. Finally, objective quantitative scoring metrics were developed to evaluate the algorithm performance and for comparison with B-mode images. The results quantitatively established that the SSA algorithm always outperformed B-mode images and that seeds could be detected accurately up to a deviation of approximately 10 degrees .

Entities:  

Mesh:

Year:  2008        PMID: 18397022      PMCID: PMC2677315          DOI: 10.1121/1.2875740

Source DB:  PubMed          Journal:  J Acoust Soc Am        ISSN: 0001-4966            Impact factor:   1.840


  12 in total

1.  The effect of seed orientation deviations on the quality of 125I prostate implants.

Authors:  J F Corbett; J J Jezioranski; J Crook; T Tran; I W Yeung
Journal:  Phys Med Biol       Date:  2001-11       Impact factor: 3.609

2.  Seed fixity in the prostate/periprostatic region following brachytherapy.

Authors:  G S Merrick; W M Butler; A T Dorsey; J H Lief; M L Benson
Journal:  Int J Radiat Oncol Biol Phys       Date:  2000-01-01       Impact factor: 7.038

3.  Automatic localization of implanted seeds from post-implant CT images.

Authors:  Haisong Liu; Gang Cheng; Yan Yu; Ralph Brasacchio; Deborah Rubens; John Strang; Lydia Liao; Edward Messing
Journal:  Phys Med Biol       Date:  2003-05-07       Impact factor: 3.609

4.  3D TRUS guided robot assisted prostate brachytherapy.

Authors:  Zhouping Wei; Mingyue Ding; Donal Downey; Aaron Fenster
Journal:  Med Image Comput Comput Assist Interv       Date:  2005

5.  Prostate postbrachytherapy seed distribution: comparison of high-resolution, contrast-enhanced, T1- and T2-weighted endorectal magnetic resonance imaging versus computed tomography: initial experience.

Authors:  B Nicolas Bloch; Robert E Lenkinski; Thomas H Helbich; Long Ngo; Renee Oismueller; Silvia Jaromi; Klaus Kubin; Robert Hawliczek; Irving D Kaplan; Neil M Rofsky
Journal:  Int J Radiat Oncol Biol Phys       Date:  2007-05-21       Impact factor: 7.038

6.  Automated seed localization from CT datasets of the prostate.

Authors:  D H Brinkmann; R W Kline
Journal:  Med Phys       Date:  1998-09       Impact factor: 4.071

7.  Transperineal 125iodine seed implantation in prostatic cancer guided by transrectal ultrasonography.

Authors:  H H Holm; N Juul; J F Pedersen; H Hansen; I Strøyer
Journal:  J Urol       Date:  1983-08       Impact factor: 7.450

8.  Factors influencing risk of acute urinary retention after TRUS-guided permanent prostate seed implantation.

Authors:  Juanita Crook; Michael McLean; Charles Catton; Ivan Yeung; John Tsihlias; Melania Pintilie
Journal:  Int J Radiat Oncol Biol Phys       Date:  2002-02-01       Impact factor: 7.038

Review 9.  Sonablate-500: transrectal high-intensity focused ultrasound for the treatment of prostate cancer.

Authors:  Rowland Illing; Mark Emberton
Journal:  Expert Rev Med Devices       Date:  2006-11       Impact factor: 3.166

10.  Using combined x-ray and MR imaging for prostate I-125 post-implant dosimetry: phantom validation and preliminary patient work.

Authors:  M E Miquel; K S Rhode; P L Acher; N D Macdougall; J Blackall; R P Gaston; S Hegde; S L Morris; R Beaney; C Deehan; R Popert; S F Keevil
Journal:  Phys Med Biol       Date:  2006-02-08       Impact factor: 3.609

View more
  3 in total

1.  Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: a pilot ex vivo study.

Authors:  Mohammad Mehrmohammadi; Azra Alizad; Randall R Kinnick; Brian J Davis; Mostafa Fatemi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

2.  Angle-dependent ultrasonic detection and imaging of two types of brachytherapy seeds using singular spectrum analysis.

Authors:  Jonathan Mamou; Sarayu Ramachandran; Ernest J Feleppa
Journal:  J Acoust Soc Am       Date:  2008-12       Impact factor: 1.840

3.  Quantitative ultrasound spectroscopic imaging for characterization of disease extent in prostate cancer patients.

Authors:  Ali Sadeghi-Naini; Ervis Sofroni; Naum Papanicolau; Omar Falou; Linda Sugar; Gerard Morton; Martin J Yaffe; Robert Nam; Alireza Sadeghian; Michael C Kolios; Hans T Chung; Gregory J Czarnota
Journal:  Transl Oncol       Date:  2015-02       Impact factor: 4.243

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.