Literature DB >> 9775371

Automated seed localization from CT datasets of the prostate.

D H Brinkmann1, R W Kline.   

Abstract

With the increasing utilization of permanent brachytherapy implants for treating carcinoma of the prostate, the importance of accurate post-treatment dose calculation also increases for assessing patient outcome and planning future treatments. An automatic method for seed localization of permanent brachytherapy implants, using CT datasets of the prostate, has been developed and tested on a phantom using an actual patient planned seed distribution. This method was also compared to results with the three-film technique for three patient datasets. The automatic method is as accurate or more accurate than the three film technique for 1 mm, 3 mm, and 5 mm contiguous CT slices, and eliminates the inter- and intra-observer variability of the manual methods. The automated method improves the localization of brachytherapy seeds while reducing the time required for the user to input information, and is demonstrated to be less operator dependent, less time consuming, and potentially more accurate than the three-film technique.

Entities:  

Mesh:

Year:  1998        PMID: 9775371     DOI: 10.1118/1.598346

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  8 in total

1.  Singular spectrum analysis applied to ultrasonic detection and imaging of brachytherapy seeds.

Authors:  Jonathan Mamou; Ernest J Feleppa
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

2.  Angle-dependent ultrasonic detection and imaging of brachytherapy seeds using singular spectrum analysis.

Authors:  Jonathan Mamou; Sarayu Ramachandran; Ernest J Feleppa
Journal:  J Acoust Soc Am       Date:  2008-04       Impact factor: 1.840

3.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  Pulse sequence considerations for simulation and postimplant dosimetry of prostate brachytherapy.

Authors:  Jingfei Ma; Marinus A Moerland; Aradhana M Venkatesan; Tharakeswara K Bathala; Rajat J Kudchadker; Kristy K Brock; Steven J Frank
Journal:  Brachytherapy       Date:  2017-01-04       Impact factor: 2.362

5.  Feasibility of vibro-acoustography with a quasi-2D ultrasound array transducer for detection and localizing of permanent prostate brachytherapy seeds: a pilot ex vivo study.

Authors:  Mohammad Mehrmohammadi; Azra Alizad; Randall R Kinnick; Brian J Davis; Mostafa Fatemi
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

6.  Clinical application and validation of an iterative forward projection matching algorithm for permanent brachytherapy seed localization from conebeam-CT x-ray projections.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

7.  Fully Balanced SSFP Without an Endorectal Coil for Postimplant QA of MRI-Assisted Radiosurgery (MARS) of Prostate Cancer: A Prospective Study.

Authors:  Jeremiah W Sanders; Aradhana M Venkatesan; Chad A Levitt; Tharakeswara Bathala; Rajat J Kudchadker; Chad Tang; Teresa L Bruno; Christine Starks; Edwin Santiago; Michelle Wells; Carl P Weaver; Jingfei Ma; Steven J Frank
Journal:  Int J Radiat Oncol Biol Phys       Date:  2020-09-24       Impact factor: 7.038

8.  A magnetic resonance-based seed localization method for I-125 prostate implants.

Authors:  Rena J Lee; Hyun Suk Suh; Kyung Ja Lee; Soome Lim; Yookyung Kim; Sungkyu Kim; Jinho Choi
Journal:  J Korean Med Sci       Date:  2007-09       Impact factor: 2.153

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.