Literature DB >> 12765331

Automatic localization of implanted seeds from post-implant CT images.

Haisong Liu1, Gang Cheng, Yan Yu, Ralph Brasacchio, Deborah Rubens, John Strang, Lydia Liao, Edward Messing.   

Abstract

An automatic localization method of implanted seeds from a series of post-implant computed tomography (CT) images is described in this paper. Post-implant CT studies were obtained for patients who underwent prostate brachytherapy. Bright areas were segmented using binary thresholding in each CT slice, and geometrical information on these areas was collected. Large areas (possibly containing two connected seeds) were split into smaller ones by geometry-based filtering in each slice. The area connectivity along the longitudinal direction was analysed using a geometry-based connection search algorithm executed on every area slice by slice, so that the connected areas were combined into one object. The weighted centroid of each object was taken as the seed position. This method was tested on a seed-containing prostate phantom as well as using CT studies from patients. Statistical analysis demonstrates that it can achieve above 99% detection rate with reliable localization accuracy and high speed. It is reliable and convenient for localizing implanted seeds on CT and can be used to assist post-implant dosimetry for prostate brachytherapy.

Entities:  

Mesh:

Year:  2003        PMID: 12765331     DOI: 10.1088/0031-9155/48/9/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Singular spectrum analysis applied to ultrasonic detection and imaging of brachytherapy seeds.

Authors:  Jonathan Mamou; Ernest J Feleppa
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

2.  Angle-dependent ultrasonic detection and imaging of brachytherapy seeds using singular spectrum analysis.

Authors:  Jonathan Mamou; Sarayu Ramachandran; Ernest J Feleppa
Journal:  J Acoust Soc Am       Date:  2008-04       Impact factor: 1.840

3.  Reconstruction of brachytherapy seed positions and orientations from cone-beam CT x-ray projections via a novel iterative forward projection matching method.

Authors:  Damodar Pokhrel; Martin J Murphy; Dorin A Todor; Elisabeth Weiss; Jeffrey F Williamson
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  Automatic seed picking for brachytherapy postimplant validation with 3D CT images.

Authors:  Guobin Zhang; Qiyuan Sun; Shan Jiang; Zhiyong Yang; Xiaodong Ma; Haisong Jiang
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-06-22       Impact factor: 2.924