Literature DB >> 18384400

Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.

Ilser Turkyilmaz1, Lars Sennerby, Burak Yilmaz, Burak Bilecenoglu, Esma Nida Ozbek.   

Abstract

BACKGROUND: Clinical studies show promising outcomes with implants inserted at the time of extraction. However, this often results in an initial bone defect at the marginal region which preferably should heal for an optimal function. Therefore, monitoring of these implants is vital. PURPOSES: The aims of this study were to determine the initial stability of implants placed into fresh extraction sockets, and to explore the correlations between the peri-implant bone levels and implant stability parameters.
MATERIALS AND METHODS: Six human cadaver mandibles including all natural teeth were selected for this study. All natural teeth were gently extracted, and 84 implants were immediately placed into fresh extraction sockets with five different implant depths. The maximum insertion torque values were recorded, and primary implant stability measurements were performed by means of resonance frequency analysis (RFA). The vertical distance between implant/abutment junction and the first bone-implant contact was recorded using a periodontal probe.
RESULTS: It was found that the insertion torque and RFA were 28.9 +/- 7 Ncm and 65.6 +/- 9 implant stability quotient (ISQ), respectively, for 420 measurements from all 84 implants. Statistically significant correlation was found between insertion torque and ISQ values (r = 0.86; p < .001) for all implants. Both insertion torque and ISQ values dramatically decreased when the amount of peri-implant vertical bone defect increased.
CONCLUSION: The results of this study demonstrated a linear relationship between peri-implant vertical bone defect depth and RFA value. It is proposed that the RFA method is sensitive to detect changes of the marginal bone level and may be used to monitor healing of peri-implant bone defects.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18384400     DOI: 10.1111/j.1708-8208.2008.00095.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  11 in total

1.  Comparison of the primary stability of orthodontic miniscrews after repeated insertion cycles.

Authors:  Felipe Nenen; Nicolás Garnica; Víctor Rojas; Rodrigo Oyonarte
Journal:  Angle Orthod       Date:  2021-05-01       Impact factor: 2.079

2.  Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach.

Authors:  Min Zhai; Bing Li; Dehua Li
Journal:  Med Biol Eng Comput       Date:  2017-02-07       Impact factor: 2.602

3.  A novel technique for measurement of orthodontic mini-implant stability using the Osstell ISQ device.

Authors:  Yara K Hosein; S Jeffrey Dixon; Amin S Rizkalla; Ali Tassi
Journal:  Angle Orthod       Date:  2018-11-01       Impact factor: 2.079

4.  Correlation between resonance frequency, insertion torque and bone-implant contact in self-cutting threaded implants.

Authors:  Yahya Açil; Jan Sievers; Aydin Gülses; Mustafa Ayna; Jörg Wiltfang; Hendrik Terheyden
Journal:  Odontology       Date:  2016-08-18       Impact factor: 2.634

5.  How precise is dental volumetric tomography in the prediction of bone density?

Authors:  Hakan Bilhan; Selda Arat; Onur Geckili
Journal:  Int J Dent       Date:  2012-05-30

6.  Influence of implant surface topography on primary stability in a standardized osteoporosis rabbit model study.

Authors:  Hiroshi Oue; Kazuya Doi; Yoshifumi Oki; Yusuke Makihara; Takayasu Kubo; Vittoria Perrotti; Adriano Piattelli; Yasumasa Akagawa; Kazuhiro Tsuga
Journal:  J Funct Biomater       Date:  2015-03-18

7.  Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study.

Authors:  Jungwon Lee; Se-Wook Pyo; Hyun-Jae Cho; Jung-Sub An; Jae-Hyun Lee; Ki-Tae Koo; Yong-Moo Lee
Journal:  J Periodontal Implant Sci       Date:  2020-02-18       Impact factor: 2.614

8.  Effects of Different Undersizing Site Preparations on Implant Stability.

Authors:  Bernardo Ferreira Lemos; Paula Lopez-Jarana; Carlos Falcao; Blanca Ríos-Carrasco; Javier Gil; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-02       Impact factor: 3.390

9.  A Retrospective Study on Insertion Torque and Implant Stability Quotient (ISQ) as Stability Parameters for Immediate Loading of Implants in Fresh Extraction Sockets.

Authors:  Giuseppe Bavetta; Giorgio Bavetta; Valentina Randazzo; Alessio Cavataio; Carlo Paderni; Vincenzo Grassia; Gianna Dipalma; Ciro Gargiulo Isacco; Antonio Scarano; Danila De Vito; Stefania Cantore; Andrea Ballini; Francesco Inchingolo
Journal:  Biomed Res Int       Date:  2019-11-03       Impact factor: 3.411

10.  Primary Stability of Dental Implants in Low-Density (10 and 20 pcf) Polyurethane Foam Blocks: Conical vs Cylindrical Implants.

Authors:  Luca Comuzzi; Margherita Tumedei; Ana Emilia Pontes; Adriano Piattelli; Giovanna Iezzi
Journal:  Int J Environ Res Public Health       Date:  2020-04-11       Impact factor: 3.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.