Literature DB >> 33378455

Comparison of the primary stability of orthodontic miniscrews after repeated insertion cycles.

Felipe Nenen, Nicolás Garnica, Víctor Rojas, Rodrigo Oyonarte.   

Abstract

OBJECTIVES: To compare the primary stability of miniscrews after repeated cycles of insertion through insertion torque (IT) measurements and resonance frequency analysis (RFA).
MATERIALS AND METHODS: Sixty titanium miniscrews were divided into two groups according to the insertion protocol: one with predrilled sites and the other self-drilled into porcine iliac crest bone specimens. Each group had three cycles of reinsertion. After each insertion, the IT and RFA were measured. The IT was measured by using a torque meter, and the RFA was measured using the Osstell ISQ device. A total of five miniscrews of each group were selected for sequential assessment of the morphology of their tip and threads using scanning electron microscopy after each insertion cycle.
RESULTS: No statistically significant differences were found in the IT values of miniscrews reinserted up to three times in the group with predrilled surgical sites. The IT value increased significantly with the number of reinsertions in the self-drilled group. The RFA value decreased as the number of insertions increased in both groups.
CONCLUSIONS: Under the conditions of this in vitro study, reinserting miniscrews deteriorates the integrity of their tip and thread. Reinsertion should be discouraged particularly when insertion sites are not predrilled.
© 2021 by The EH Angle Education and Research Foundation, Inc.

Keywords:  Insertion torque; Miniscrews; Reinsertion; Resonance frequency analysis

Mesh:

Substances:

Year:  2021        PMID: 33378455      PMCID: PMC8084464          DOI: 10.2319/050120-375.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  30 in total

1.  Factors affecting the long-term stability of orthodontic mini-implants.

Authors:  Mitsuru Motoyoshi; Miwa Uemura; Akiko Ono; Kumiko Okazaki; Toru Shigeeda; Noriyoshi Shimizu
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-05       Impact factor: 2.650

2.  Recommended placement torque when tightening an orthodontic mini-implant.

Authors:  Mitsuru Motoyoshi; Masayuki Hirabayashi; Miwa Uemura; Noriyoshi Shimizu
Journal:  Clin Oral Implants Res       Date:  2006-02       Impact factor: 5.977

Review 3.  Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications.

Authors:  Lars Sennerby; Neil Meredith
Journal:  Periodontol 2000       Date:  2008       Impact factor: 7.589

4.  The influence of miniscrew insertion torque.

Authors:  Melissa V Nguyen; John Codrington; Lloyd Fletcher; Craig W Dreyer; Wayne J Sampson
Journal:  Eur J Orthod       Date:  2018-01-23       Impact factor: 3.075

5.  The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study.

Authors:  L Pagliani; L Sennerby; A Petersson; D Verrocchi; S Volpe; P Andersson
Journal:  J Oral Rehabil       Date:  2012-12-28       Impact factor: 3.837

6.  Stability of secondarily inserted orthodontic miniscrews after failure of the primary insertion for maxillary anchorage: Maxillary buccal area vs midpalatal suture area.

Authors:  Shunsuke Uesugi; Satoshi Kokai; Zuisei Kanno; Takashi Ono
Journal:  Am J Orthod Dentofacial Orthop       Date:  2018-01       Impact factor: 2.650

7.  Prognosis of primary and secondary insertions of orthodontic miniscrews: What we have learned from 500 implants.

Authors:  Shunsuke Uesugi; Satoshi Kokai; Zuisei Kanno; Takashi Ono
Journal:  Am J Orthod Dentofacial Orthop       Date:  2017-08       Impact factor: 2.650

8.  Application of a wireless resonance frequency transducer to assess primary stability of orthodontic mini-implants: an in vitro study in pig ilia.

Authors:  Yu-Yu Su; Benedict Wilmes; Ralf Hönscheid; Dieter Drescher
Journal:  Int J Oral Maxillofac Implants       Date:  2009 Jul-Aug       Impact factor: 2.804

9.  Anatomic assessment of the mandibular buccal shelf for miniscrew insertion in white patients.

Authors:  Tarek Elshebiny; Juan Martin Palomo; Sebastian Baumgaertel
Journal:  Am J Orthod Dentofacial Orthop       Date:  2018-04       Impact factor: 2.650

10.  Effect of recycling protocol on mechanical strength of used mini-implants.

Authors:  Sérgio Estelita; Guilherme Janson; Kelly Chiqueto; Eduardo Silveira Ferreira
Journal:  Int J Dent       Date:  2014-07-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.