Literature DB >> 28176266

Effects on the torsional vibration behavior in the investigation of dental implant osseointegration using resonance frequency analysis: a numerical approach.

Min Zhai1, Bing Li2, Dehua Li3.   

Abstract

Resonance frequency analysis (RFA) methods are widely used to assess implant stability, particularly the Osstell® device. The potential effects associated with this method have been discussed in the literature. Torsional RFA (T-RFA), mentioned in our previous study, could represent a new measurement method. The purpose of this study was to simulate T-shaped and Osstell® transducer-implant-bone system models; compare their vibration modes and corresponding resonance frequencies; and investigate the effects of their parameters, such as the effective implant length (EIL), bone quality, and osseointegration level, on the torsional resonance frequency (TRF) and bending resonance frequency (BRF) using three-dimensional finite element analysis. Following the finite element model validation, the TRFs and BRFs for three different EILs and four types of bone quality were obtained, and the change rates during 25 degrees of osseointegration were observed. The analysis showed that an increase in the EIL and a decrease in bone quality have less effect on the declination rate of TRFs than on that of BRFs. TRFs are highly sensitive to the stiffness of the implant-bone interface during the healing period. It was concluded that T-RFA has better sensitivity and specificity.

Keywords:  Dental implants; Finite element analysis; Osseointegration; Resonance frequency analysis; Torsional vibration

Mesh:

Substances:

Year:  2017        PMID: 28176266     DOI: 10.1007/s11517-017-1612-3

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  28 in total

1.  Elasticity of alveolar bone near dental implant-bone interfaces after one month's healing.

Authors:  M C Chang; C C Ko; C C Liu; W H Douglas; R DeLong; W-J Seong; J Hodges; K-N An
Journal:  J Biomech       Date:  2003-08       Impact factor: 2.712

Review 2.  Validity and clinical significance of biomechanical testing of implant/bone interface.

Authors:  Carlos Aparicio; Niklaus P Lang; Bo Rangert
Journal:  Clin Oral Implants Res       Date:  2006-10       Impact factor: 5.977

3.  Dental implants press fit phenomena: biomechanical analysis considering bone inelastic response.

Authors:  Arturo N Natali; Emanuele L Carniel; Piero G Pavan
Journal:  Dent Mater       Date:  2009-01-06       Impact factor: 5.304

4.  The application of resonance frequency measurements to study the stability of titanium implants during healing in the rabbit tibia.

Authors:  N Meredith; F Shagaldi; D Alleyne; L Sennerby; P Cawley
Journal:  Clin Oral Implants Res       Date:  1997-06       Impact factor: 5.977

5.  Functional apparent moduli as predictors of oral implant osseointegration dynamics.

Authors:  Po-Chun Chang; Yang-Jo Seol; Noboru Kikuchi; Steven A Goldstein; William V Giannobile
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2010-07       Impact factor: 3.368

6.  Torsional resonance frequency analysis: a novel method for assessment of dental implant stability.

Authors:  Yu-Long Tang; Bing Li; Wei Jin; De-Hua Li
Journal:  Clin Oral Implants Res       Date:  2014-02-25       Impact factor: 5.977

7.  Effects of low-intensity pulsed ultrasound on dental implant osseointegration: a preliminary report.

Authors:  Yakup Ustun; Ozgur Erdogan; Mehmet Kurkcu; Tolga Akova; Ibrahim Damlar
Journal:  Eur J Dent       Date:  2008-10

8.  Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface.

Authors:  Reva M Barewal; Thomas W Oates; Neil Meredith; David L Cochran
Journal:  Int J Oral Maxillofac Implants       Date:  2003 Sep-Oct       Impact factor: 2.804

9.  Effects of material properties of femoral hip components on bone remodeling.

Authors:  H Weinans; R Huiskes; H J Grootenboer
Journal:  J Orthop Res       Date:  1992-11       Impact factor: 3.494

10.  Early loading of maxillary fixed cross-arch dental prostheses supported by six or eight oxidized titanium implants: results after 1 year of loading, case series.

Authors:  Morgan Olsson; Göran Urde; Jan B Andersen; Lars Sennerby
Journal:  Clin Implant Dent Relat Res       Date:  2003       Impact factor: 3.932

View more
  1 in total

1.  Evaluating the dynamic behaviour of bone anchored hearing aids using a finite element model and its applications to implant stability assessment.

Authors:  Mostafa Mohamed; Lindsey Westover
Journal:  Med Biol Eng Comput       Date:  2022-07-20       Impact factor: 3.079

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.