Literature DB >> 33748560

Characterization or Monolithic Scintillation Detectors Etched with Laser Induced Optical Barriers.

J V Panetta1, S Surti2, B Singh3, J S Karp4.   

Abstract

Several groups are actively investigating the performance of monolithic (continuous) scintillation detectors using a variety of crystal thicknesses, photo-sensor configurations, and surface treatments. This work explores the performance of thick LYSO crystals that would be applicable to a whole-body PET system. The crystals were etched with laser induced optical barriers (LIOBs) to alter the behavior of the light spread within the crystal in order to improve the performance of the detector. We studied the behavior of the LIOBs in response to optical light using small cubes of LYSO with a variety of laser etching parameters to characterize the impact of the optical barriers. We demonstrated that the opacity of the etchings can be altered by varying the parameters of the laser etching, which influences the depth-dependent light response and spatial resolution in the thick crystal. We successfully etched several crystals, as large as 50×50×25-mm3 thick, with a fine grid of LIOBs, and achieved an average spatial resolution close to 3 mm (FWHM) with 511-keV gammas.

Entities:  

Keywords:  Laser induced optical barriers; monolithic scintillators

Year:  2018        PMID: 33748560      PMCID: PMC7970668          DOI: 10.1109/trpms.2018.2875156

Source DB:  PubMed          Journal:  IEEE Trans Radiat Plasma Med Sci        ISSN: 2469-7303


  13 in total

1.  Intrinsic spatial resolution evaluation of the X'tal cube PET detector based on a 3D crystal block segmented by laser processing.

Authors:  Eiji Yoshida; Hideaki Tashima; Naoko Inadama; Fumihiko Nishikido; Takahiro Moriya; Tomohide Omura; Mitsuo Watanabe; Hideo Murayama; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2012-07-11

2.  A novel, SiPM-array-based, monolithic scintillator detector for PET.

Authors:  Dennis R Schaart; Herman T van Dam; Stefan Seifert; Ruud Vinke; Peter Dendooven; Herbert Löhner; Freek J Beekman
Journal:  Phys Med Biol       Date:  2009-05-15       Impact factor: 3.609

3.  Parametric positioning of a continuous crystal PET detector with depth of interaction decoding.

Authors:  T Ling; T H Burnett; T K Lewellen; R S Miyaoka
Journal:  Phys Med Biol       Date:  2008-03-10       Impact factor: 3.609

4.  Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system.

Authors:  Radosław Marcinkowski; Pieter Mollet; Roel Van Holen; Stefaan Vandenberghe
Journal:  Phys Med Biol       Date:  2016-03-07       Impact factor: 3.609

5.  Improved image quality using monolithic scintillator detectors with dual-sided readout in a whole-body TOF-PET ring: a simulation study.

Authors:  Valerio Tabacchini; Suleman Surti; Giacomo Borghi; Joel S Karp; Dennis R Schaart
Journal:  Phys Med Biol       Date:  2017-02-13       Impact factor: 3.609

6.  A novel single-ended readout depth-of-interaction PET detector fabricated using sub-surface laser engraving.

Authors:  H Uchida; T Sakai; H Yamauchi; K Hakamata; K Shimizu; T Yamashita
Journal:  Phys Med Biol       Date:  2016-08-19       Impact factor: 3.609

7.  Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation.

Authors:  Giacomo Borghi; Valerio Tabacchini; Dennis R Schaart
Journal:  Phys Med Biol       Date:  2016-06-10       Impact factor: 3.609

8.  Novel laser-processed CsI:Tl detector for SPECT.

Authors:  H Sabet; L Bläckberg; D Uzun-Ozsahin; G El-Fakhri
Journal:  Med Phys       Date:  2016-05       Impact factor: 4.071

9.  Combining Surface Treatments with Shallow Slots to Improve the Spatial Resolution Performance of Continuous, Thick LYSO Detectors for PET.

Authors:  M Kaul; S Surti; J S Karp
Journal:  IEEE Trans Nucl Sci       Date:  2013-02-01       Impact factor: 1.679

10.  GPU-based optical propagation simulator of a laser-processed crystal block for the X'tal cube PET detector.

Authors:  Yuma Ogata; Takashi Ohnishi; Takahiro Moriya; Naoko Inadama; Fumihiko Nishikido; Eiji Yoshida; Hideo Murayama; Taiga Yamaya; Hideaki Haneishi
Journal:  Radiol Phys Technol       Date:  2013-07-30
View more
  1 in total

1.  A layered single-side readout depth of interaction time-of-flight-PET detector.

Authors:  L Bläckberg; S Sajedi; G El Fakhri; H Sabet
Journal:  Phys Med Biol       Date:  2021-02-11       Impact factor: 3.609

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.