Literature DB >> 16555771

Operational verification of a 40-MHz annular array transducer.

Jeffrey A Ketterling1, Sarayu Ramachandran, Orlando Aristizábal.   

Abstract

An experimental system to take advantage of the imaging capabilities of a 5-ring polyvinylidene fluoride (PVDF)-based annular array is presented. The array has a 6-mm total aperture and a 12-mm geometric focus. The experimental system is designed to pulse a single element of the array and then digitize the received data of all array channels simultaneously. All transmit/receive pairs are digitized and then the data are post-processed with a synthetic-focusing technique to achieve an enhanced depth of field (DOF). The performance of the array is experimentally tested with a wire phantom consisting of 25-microm diameter wires diagonally spaced at 1-mm by 1-mm intervals. The phantom permitted the efficacy of the synthetic-focusing algorithm to be tested and was also used for two-way beam characterization. Experimental results are compared to a spatial impulse response method beam simulation. After synthetic focusing, the two-way echo amplitude was enhanced over the range of 8 to 19 mm and the 6-dB DOF spanned from 9 to 15 mm. For a wire at a fixed axial depth, the relative time delays between transmit/receive ring pairs agreed with theoretical predictions to within +/- 2 ns. To further test the system, B-mode images of an excised bovine eye were rendered.

Entities:  

Year:  2006        PMID: 16555771      PMCID: PMC1770896          DOI: 10.1109/tuffc.2006.1610571

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  15 in total

Review 1.  Advances in ultrasound biomicroscopy.

Authors:  F S Foster; C J Pavlin; K A Harasiewicz; D A Christopher; D H Turnbull
Journal:  Ultrasound Med Biol       Date:  2000-01       Impact factor: 2.998

2.  Unit-delay focusing architecture and integrated-circuit implementation for high-frequency ultrasound.

Authors:  James R Talman; Steven L Garverick; Christine E Morton; Geoffrey R Lockwood
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

Review 3.  Ultrasound biomicroscopy-Doppler in mouse cardiovascular development.

Authors:  Colin K L Phoon; Daniel H Turnbull
Journal:  Physiol Genomics       Date:  2003-06-24       Impact factor: 3.107

4.  Design and fabrication of annular arrays for high-frequency ultrasound.

Authors:  Jeremy A Brown; Christine E M Démoré; Geoffrey R Lockwood
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-08       Impact factor: 2.725

5.  Design, fabrication, and evaluation of high frequency, single-element transducers incorporating different materials.

Authors:  Kevin A Snook; Jian-Zhong Zhao; Carlos H F Alves; Jonathan M Cannata; Wo-Hsing Chen; Richard J Meyer; Timothy A Ritter; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-02       Impact factor: 2.725

6.  Three-dimensional high-frequency ultrasonic parameter imaging of anterior segment pathology.

Authors:  R H Silverman; M J Rondeau; F L Lizzi; D J Coleman
Journal:  Ophthalmology       Date:  1995-05       Impact factor: 12.079

7.  Transient fields of concave annular arrays.

Authors:  M Arditi; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1981-01       Impact factor: 1.578

8.  An annular array system for high resolution breast echography.

Authors:  M Arditi; W B Taylor; F S Foster; J W Hunt
Journal:  Ultrason Imaging       Date:  1982-01       Impact factor: 1.578

9.  The design and fabrication of high frequency poly(vinylidene fluoride) transducers.

Authors:  M D Sherar; F S Foster
Journal:  Ultrason Imaging       Date:  1989-04       Impact factor: 1.578

10.  Design of efficient, broadband single-element (20-80 MHz) ultrasonic transducers for medical imaging applications.

Authors:  Jonathan M Cannata; Timothy A Ritter; Wo-Hsing Chen; Ronald H Silverman; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-11       Impact factor: 2.725

View more
  16 in total

1.  40-MHz annular array imaging of mouse embryos.

Authors:  Orlando Aristizábal; Jeffrey A Ketterling; Daniel H Turnbull
Journal:  Ultrasound Med Biol       Date:  2006-11       Impact factor: 2.998

2.  Chirp-coded excitation imaging with a high-frequency ultrasound annular array.

Authors:  Jonathan Mamou; Jeffrey A Ketterling; Ronald H Silverman
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-02       Impact factor: 2.725

3.  Improved high-resolution ultrasonic imaging of the eye.

Authors:  Ronald H Silverman; Jeffrey A Ketterling; Jonathan Mamou; D Jackson Coleman
Journal:  Arch Ophthalmol       Date:  2008-01

4.  High-frequency annular array with coaxial illumination for dual-modality ultrasonic and photoacoustic imaging.

Authors:  Erwan Filoux; Ashwin Sampathkumar; Parag V Chitnis; Orlando Aristizábal; Jeffrey A Ketterling
Journal:  Rev Sci Instrum       Date:  2013-05       Impact factor: 1.523

5.  Correspondence - Characterization of the effective performance of a high-frequency annular-array-based imaging system using anechoic-pipe phantoms.

Authors:  Erwan Filoux; Jonathan Mamou; Carmel M Moran; Stephen D Pye; Jeffrey A Ketterling
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-12       Impact factor: 2.725

6.  A high-frequency linear ultrasonic array utilizing an interdigitally bonded 2-2 piezo-composite.

Authors:  Jonathan M Cannata; Jay A Williams; Lequan Zhang; Chang-Hong Hu; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-10       Impact factor: 2.725

7.  High-frequency ultrasonic imaging of the anterior segment using an annular array transducer.

Authors:  Ronald H Silverman; Jeffrey A Ketterling; D Jackson Coleman
Journal:  Ophthalmology       Date:  2006-11-30       Impact factor: 12.079

8.  High-frequency piezopolymer transducers with a copper-clad polyimide backing layer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal; Daniel H Turnbull
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-07       Impact factor: 2.725

9.  A flexible annular-array imaging platform for micro-ultrasound.

Authors:  Weibao Qiu; Yanyan Yu; Hamid Reza Chabok; Cheng Liu; Fu Keung Tsang; Qifa Zhou; K Kirk Shung; Hairong Zheng; Lei Sun
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-01       Impact factor: 2.725

10.  Prospective ECG-gated mouse cardiac imaging with a 34-MHz annular array transducer.

Authors:  Jeffrey A Ketterling; Orlando Aristizábal
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-07       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.