Literature DB >> 28540493

Investigation of corneal biomechanics at moderate to high refractive errors.

Nehir İnceoğlu1, Sinan Emre2, Mahmut Oğuz Ulusoy3.   

Abstract

PURPOSE: Corneal hysteresis (CH) and corneal resistance factor (CRF) are corneal biomechanical parameters which were measured by ocular response analyzer (ORA). Aim of this study was to define the CH and CRF in high myopic and hyperopic patients and compare the results with emmetropic control group.
METHODS: A total of 193 eyes of 100 healthy volunteers were included. Study groups were high myopic patients (n = 27) with spherical refractive errors (SRE) of greater than -5.00D, high hyperopic patients (n = 20) with SRE of greater than +3.00D and controls (n = 53) with SRE between ± 1.00D. All subjects underwent IOP and corneal biomechanical evaluation with the ORA. Also Goldmann applanation tonometry (GAT), central corneal thickness (CCT), corneal curvature and axial length measurements were taken.
RESULTS: Mean age of groups was 30.7 ± 6.9, 29.1 ± 7.7, 28.9 ± 5.6 years (p > 0.05). Among study groups except CRF and CCT, all parameters were significantly different between study groups. CH was lowest in the high myopic group and highest in the high hyperopia. In all groups, there were significant correlations between CH and CRF, CCT, SRE, SE (spherical equivalent), AL (axial length) and between CRF and CCT. GAT and IOPg (Goldmann-correlated intraocular pressure) measurements were significantly correlated with CCT (p < 0.05). One of the major findings was as the CH approaches 11.2 mmHg, IOPcc (corneal-compensated intraocular pressure) and IOPg get close to each other.
CONCLUSIONS: The results revealed that CRF is not affected by refractive errors and IOPcc is not affected by any other ocular parameter. The difference between IOPcc and IOPg was greatest in myopic group, and IOP (intraocular pressure) measurement in these patients deserves high suspicion.

Entities:  

Keywords:  Corneal biomechanics; Corneal hysteresis; Corneal resistance factor; High hyperopia; High myopia; Refractive error

Mesh:

Year:  2017        PMID: 28540493     DOI: 10.1007/s10792-017-0560-0

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  38 in total

Review 1.  Frequency, course, and impact of correctable visual impairment (uncorrected refractive error).

Authors:  Julie Schneider; Stephen R Leeder; Bamini Gopinath; Jie Jin Wang; Paul Mitchell
Journal:  Surv Ophthalmol       Date:  2010-09-20       Impact factor: 6.048

2.  New Scheimpflug Dynamic In Vivo Curve Analyses to Characterize Biomechanical Changes of the Cornea After Cross-linking for Progressive Keratoconus.

Authors:  Johannes Steinberg; Andreas Frings; Aiham Mousli; Maria K Casagrande; Vasyl Druchkiv; Toam Katz; Stephan J Linke
Journal:  J Refract Surg       Date:  2016-01       Impact factor: 3.573

3.  Determining in vivo biomechanical properties of the cornea with an ocular response analyzer.

Authors:  David A Luce
Journal:  J Cataract Refract Surg       Date:  2005-01       Impact factor: 3.351

4.  Intraocular pressure in a selected sample of myopic and nonmyopic Chinese children.

Authors:  M H Edwards; B Brown
Journal:  Optom Vis Sci       Date:  1993-01       Impact factor: 1.973

5.  Epidemiologic study of ocular refraction among schoolchildren in Taiwan in 1995.

Authors:  L L Lin; Y F Shih; C B Tsai; C J Chen; L A Lee; P T Hung; P K Hou
Journal:  Optom Vis Sci       Date:  1999-05       Impact factor: 1.973

6.  High myopia and glaucoma susceptibility the Beijing Eye Study.

Authors:  Liang Xu; Yaxing Wang; Shuang Wang; Yun Wang; Jost B Jonas
Journal:  Ophthalmology       Date:  2006-11-21       Impact factor: 12.079

7.  Comparison of IOP measurements between ORA and GAT in normal Chinese.

Authors:  Andrew Lam; Davie Chen; Roger Chiu; Wan-Sang Chui
Journal:  Optom Vis Sci       Date:  2007-09       Impact factor: 1.973

8.  Assessment of corneal biomechanical properties and intraocular pressure with the Ocular Response Analyzer in childhood myopia.

Authors:  Pei-Yao Chang; Shu-Wen Chang; Jiun-Yi Wang
Journal:  Br J Ophthalmol       Date:  2009-10-14       Impact factor: 4.638

9.  Corneal hysteresis and axial length among Chinese secondary school children: the Xichang Pediatric Refractive Error Study (X-PRES) report no. 4.

Authors:  Yue Song; Nathan Congdon; Liping Li; Zhongxia Zhou; Kai Choi; Dennis S C Lam; Chi Pui Pang; Zhenling Xie; Xueyu Liu; Abhishek Sharma; Weihong Chen; Mingzhi Zhang
Journal:  Am J Ophthalmol       Date:  2008-03-10       Impact factor: 5.258

10.  Assessment of corneal biomechanical properties and intraocular pressure in myopic spanish healthy population.

Authors:  María A Del Buey; Laura Lavilla; Francisco J Ascaso; Elena Lanchares; Valentín Huerva; José A Cristóbal
Journal:  J Ophthalmol       Date:  2014-02-25       Impact factor: 1.909

View more
  3 in total

1.  Corneal Biomechanical Properties in Varying Severities of Myopia.

Authors:  Mohammad-Reza Sedaghat; Hamed Momeni-Moghaddam; Abbas Azimi; Zohreh Fakhimi; Mohammed Ziaei; Zeynad Danesh; Cynthia J Roberts; Naeemeh Monfared; Alireza Jamali
Journal:  Front Bioeng Biotechnol       Date:  2021-01-21

2.  The Effect of Axial Length Elongation on Corneal Biomechanical Property.

Authors:  Guihua Liu; Hua Rong; Ping Zhang; Yu Xue; Bei Du; Biying Wang; Jiamei Hu; Zhi Chen; Ruihua Wei
Journal:  Front Bioeng Biotechnol       Date:  2021-12-02

3.  The Effect of Thyroid Eye Disease on Corneal Biomechanical Properties.

Authors:  Melis Cansu Comert; Sezen Yilmaz; Ayse Yildiz Tas; Afsun Sahin
Journal:  Beyoglu Eye J       Date:  2022-08-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.