Literature DB >> 28161802

Influence of across-pupil sutures on the optical quality of intraocular lenses.

Chang Rae Rho1,2, Min-Ji Kim2,3, Choun-Ki Joo4,5.   

Abstract

PURPOSE: In cases of pupillary capture after previous transscleral fixation of an intraocular lens (IOL), an across-pupil suture technique is sometimes used to stabilize the IOL. We investigated the optical effects of 10-0 polypropylene sutures placed across the pupil.
METHODS: Optical performance was evaluated using the optical bench metrology system, and a single-piece IOL was used in an optical bench system consisting of a model eye, a high-resolution Hartmann-Shack wave front sensor, and an image capturing device with 2.0, 3.0, 4.0, and 4.5 mm apertures with distance focus. To simulate across-pupil sutures, two 10-0 polypropylene sutures were placed 2 mm apart across the pupil. The focus image, spherical aberration, and image quality were measured and compared with and without sutures.
RESULTS: When pupil size increased, spherical aberration increased, irrespective of sutures. No difference was found in spherical aberration with and without sutures, and image qualities at 17.6 and 35.2 cycles per degree were not affected by the across-pupil sutures.
CONCLUSIONS: The differences in optical quality using across-pupil 10-0 polypropylene sutures were clinically negligible.

Entities:  

Keywords:  Across-pupil suture; IOL dislocation; Optical bench; Spherical aberration

Mesh:

Year:  2017        PMID: 28161802     DOI: 10.1007/s10792-016-0441-y

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  14 in total

1.  Eye models for the prediction of contrast vision in patients with new intraocular lens designs.

Authors:  Patricia A Piers; N E Sverker Norrby; Ulrich Mester
Journal:  Opt Lett       Date:  2004-04-01       Impact factor: 3.776

2.  Evaluation of optical performance of 4 aspheric toric intraocular lenses using an optical bench system: Influence of pupil size, decentration, and rotation.

Authors:  Min-Ji Kim; Young-Sik Yoo; Choun-Ki Joo; Geunyoung Yoon
Journal:  J Cataract Refract Surg       Date:  2015-10       Impact factor: 3.351

3.  Optical performance in rezoom and array multifocal intraocular lenses in vitro.

Authors:  Takushi Kawamorita; Hiroshi Uozato; Daisuke Aizawa; Kazutaka Kamiya; Kimiya Shimizu
Journal:  J Refract Surg       Date:  2009-05       Impact factor: 3.573

4.  Late in-the-bag intraocular lens dislocation requiring explantation: risk factors and outcomes.

Authors:  R Fernández-Buenaga; J L Alio; A L Pérez-Ardoy; A Larrosa-Quesada; L Pinilla-Cortés; R Barraquer; J L Alio; F J Muñoz-Negrete
Journal:  Eye (Lond)       Date:  2013-06-14       Impact factor: 3.775

5.  Safety-basket suture for management of malpositioned posterior chamber intraocular lens.

Authors:  Samuel Masket; Nicole R Fram
Journal:  J Cataract Refract Surg       Date:  2013-11       Impact factor: 3.351

6.  Anterior segment optical coherence tomography findings of reverse pupillary block after scleral-fixated sutured posterior chamber intraocular lens implantation.

Authors:  Tomomi Higashide; Fuki Shimizu; Akira Nishimura; Kazuhisa Sugiyama
Journal:  J Cataract Refract Surg       Date:  2009-09       Impact factor: 3.351

7.  Pupillary block after pupillary capture of an AcrySof intraocular lens.

Authors:  S Nagamoto; T Kohzuka; T Nagamoto
Journal:  J Cataract Refract Surg       Date:  1998-09       Impact factor: 3.351

8.  Simple technique to treat pupillary capture after transscleral fixation of intraocular lens.

Authors:  Ignasi Jürgens; Amanda Rey
Journal:  J Cataract Refract Surg       Date:  2015-01       Impact factor: 3.351

9.  Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central hole.

Authors:  Tetsu Shiratani; Kimiya Shimizu; Kunitoshi Fujisawa; Shigekazu Uga; Koichi Nagano; Yuuki Murakami
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-02-26       Impact factor: 3.117

10.  Phenomenological model for interpreting the clinical significance of the in vitro optical transfer function.

Authors:  A J Lang; V Lakshminarayanan; V Portney
Journal:  J Opt Soc Am A       Date:  1993-07       Impact factor: 2.129

View more
  1 in total

1.  Rectangular loop suture to correct iris capture of the posterior chamber intraocular lens.

Authors:  Ke Lin; Zhixiang Hu; Zhong Lin; Tianyu Chen; Yongping Tang; Ronghan Wu
Journal:  BMC Ophthalmol       Date:  2020-09-25       Impact factor: 2.209

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.