PURPOSE: To examine the response of the lens to varying sizes of perforating injury.
METHODS: Four-week-old mice were used. Injuries consisted of pricking in the central region of the lens by transcorneal insertion of needles of two different sizes. After injury, the eyeballs were removed sequentially at various intervals up to 30 days and examined morphologically.
RESULTS: The mouse lens showed three patterns of reaction; retained transparency, posterior opacity, and anterior opacity. (1) When the lens remained clear, the injury was small in area. The damaged portion of the lens was repaired by epithelial proliferation. (2) When opacity occurred abruptly at the posterior cortical area, epithelial damage was mild and lens fiber damage was relatively severe. Evans blue dye moved toward the posterior polar region along the cortical fiber arrangement. (3) When opacity developed abruptly at the anterior cortex, the size of epithelial damage and the damage to lens fibers were extensive. The posterior cortex remained transparent. Evans blue dye remained in the anterior polar region just beneath the injured part.
CONCLUSION: It was found that the size of the injured area is a determinant of repair or opacity, and the site of opacity is dependent on the severity of epithelial damage and the location of the liquefied area.

Entities:  

Mesh:

Year:  2002        PMID: 12225817     DOI: 10.1016/s0021-5155(02)00532-4

Source DB:  PubMed          Journal:  Jpn J Ophthalmol        ISSN: 0021-5155            Impact factor:   2.447


  2 in total

1.  The ultrastructural alterations in the lens capsule and epithelium in eyes with traumatic white cataract.

Authors:  Merve Inanc; Kemal Tekin; Yasemin Ozdamar Erol; Mustafa Fevzi Sargon; Mustafa Koc; Ozlem Budakoglu; Pelin Yılmazbas
Journal:  Int Ophthalmol       Date:  2017-11-30       Impact factor: 2.031

2.  Crystalline lens changes in porcine eyes with implanted phakic IOL (ICL) with a central hole.

Authors:  Tetsu Shiratani; Kimiya Shimizu; Kunitoshi Fujisawa; Shigekazu Uga; Koichi Nagano; Yuuki Murakami
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-02-26       Impact factor: 3.117

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.