Abstract

In this paper we describe a high-fidelity perfusion simulation system intended for use in the training and continuing education of perfusionists. The system comprises a hydraulic simulator, an electronic interface unit and a controlling computer with associated real-time computer models. It is designed for use within an actual operating theatre, or within a specialized simulation facility. The hydraulic simulator can be positioned on an operating table and physically connected to the circuit of the institutional heart-lung machine. The institutional monitoring system is used to display the arterial and central venous pressures, the ECG and the nasopharyngeal temperature using appropriate connections. The simulator is able to reproduce the full spectrum of normal and abnormal events that may present during the course of cardiopulmonary bypass. The system incorporates a sophisticated blood gas model that accurately predicts the behavior of a modern, hollow-fiber oxygenator. Output from this model is displayed in the manner of an in-line blood gas electrode and is updated every 500 msecs. The perfusionist is able to administer a wide variety of drugs during a simulation session including: vasoconstrictors (metaraminol, epinephrine and phenylephrine), a vasodilator (sodium nitroprusside), chronotropes (epinephrine and atropine), an inotrope (epinephrine) and modifiers of coagulation (heparin and protamine). Each drug has a pharmacokinetic profile based on a three-compartment model plus an effect compartment. The simulation system has potential roles in the skill training of perfusionists, the development of crisis management protocols, the certification and accreditation of perfusionists and the evaluation of new perfusion equipment and/or techniques.

Entities:  

Mesh:

Year:  2007        PMID: 18293807      PMCID: PMC4680687     

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  13 in total

1.  An update on perfusion safety: does the type of perfusion practice affect the rate of incidents related to cardiopulmonary bypass?

Authors:  A H Stammers; B L Mejak
Journal:  Perfusion       Date:  2001-05       Impact factor: 1.972

2.  Departmental use of perfusion crisis management drills: 2002 survey results.

Authors:  Richard Ginther; Roy Fillingham; Bruce Searles; Edward Darling
Journal:  Perfusion       Date:  2003-09       Impact factor: 1.972

3.  On the determination of the physiologically effective pressures of oxygen and carbon dioxide in alveolar air.

Authors:  R L RILEY; J L LILIENTHAL
Journal:  Am J Physiol       Date:  1946-09

Review 4.  Simulation: a new frontier in surgical education.

Authors:  Sanjeev Dutta; Thomas M Krummel
Journal:  Adv Surg       Date:  2006

5.  A new oxygenator change-out system and procedure.

Authors:  U Da Broi; V Adami; E Falasca; W Malangone; S Crini; A Degrassi
Journal:  Perfusion       Date:  2006-12       Impact factor: 1.972

6.  Virtual extracorporeal circulation process.

Authors:  F Boschetti; F M Montevecchi; R Fumero
Journal:  Int J Artif Organs       Date:  1997-06       Impact factor: 1.595

7.  Australasian perfusion incident survey.

Authors:  O F Jenkins; R Morris; J M Simpson
Journal:  Perfusion       Date:  1997-09       Impact factor: 1.972

8.  A digital computer model to teach and study gas transport and exchange between lungs, blood and tissues ('MacPuf').

Authors:  C J Dickinson
Journal:  J Physiol       Date:  1972-07       Impact factor: 5.182

9.  A total heart/lung bypass simulator.

Authors:  R J Leonard
Journal:  ASAIO Trans       Date:  1988 Jul-Sep

10.  Measuring the efficiency of an artificial lung: 1. Carbon dioxide transfer.

Authors:  D A Pybus; M Lyon; J Hamilton; M Henderson
Journal:  Anaesth Intensive Care       Date:  1991-08       Impact factor: 1.669

View more
  9 in total

1.  Evaluation of basic perfusion techniques, ECCSIM-Lite simulator.

Authors:  Asako Tokumine; Shinji Ninomiya; Megumi Tokaji; Tatsuya Kurosaki; Yasuko Tomizawa
Journal:  J Extra Corpor Technol       Date:  2010-06

2.  Self-priming hemodynamic reservoir and inline flow meter for a cardiopulmonary bypass simulation.

Authors:  David Raasch; Jon Austin; Richard Tallman
Journal:  J Extra Corpor Technol       Date:  2010-06

3.  Emergent Cardiopulmonary Bypass during Cardiac Surgery.

Authors:  Amy M White; Jeffrey B Riley; John M Stulak; Kevin L Greason
Journal:  J Extra Corpor Technol       Date:  2015-12

4.  Use of an extracorporeal circulation perfusion simulator: evaluation of its accuracy and repeatability.

Authors:  Asako Tokumine; Naoki Momose; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2013-12       Impact factor: 1.731

5.  Vicarious audiovisual learning in perfusion education.

Authors:  Thomas E Rath; David W Holt
Journal:  J Extra Corpor Technol       Date:  2010-12

6.  Objective Content Validation of the Hemodynamic and Technical Parameters of the OrpheusTM Cardiopulmonary Bypass Simulator.

Authors:  Bruce E Searles; Edward M Darling; Jeffrey B Riley; Jacob McNinch; Erik Rufa; Jason R Wiles
Journal:  J Extra Corpor Technol       Date:  2021-12

7.  Development of the orpheus perfusion simulator for use in high-fidelity extracorporeal membrane oxygenation simulation.

Authors:  William Lansdowne; David Machin; David J Grant
Journal:  J Extra Corpor Technol       Date:  2012-12

8.  Virtual patient simulator for the perfusion resource management drill.

Authors:  Shinji Ninomiya; Megumi Tokaji; Asako Tokumine; Tatsuya Kurosaki
Journal:  J Extra Corpor Technol       Date:  2009-12

9.  The effect of acute sleep deprivation and fatigue in cardiovascular perfusion students: a mixed methods study.

Authors:  Ashley B Hodge; Alexandra C Snyder; Adam L Fernandez; Andrea D Boan; Angela M Malek; Joseph J Sistino
Journal:  J Extra Corpor Technol       Date:  2012-09
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.