X-ray scattering in single- and dual-source CT.

Klaus J Engel1, Christoph Herrmann, Günter Zeitler.   

Abstract

For medical imaging applications, such as cardiac imaging, dual-source computed tomography (CT) improves the temporal resolution by the simultaneous use of two cone beams, which acquire twice as many projections as single-source CT does within the same time interval. Besides this advantage, a drawback of such a system is additional x-ray scatter originating from the extra (cross-illuminating) cone beam. In this work, a comparison with single-source CT images is performed under same-dose conditions for two different thorax phantoms, and for different cone beam angles corresponding to a coverage of 20, 40, 80, and 160 mm on the rotation axis (z coverage). As a general result, the HU-magnitude of scatter-induced streak and cupping artifacts scale almost proportional to the illuminated volume. In dual-source CT, cross scatter induces a further factor of almost 2 in the scaling of artifacts in comparison to single-source CT. For all examined systems, the scatter-induced noise reduces the contrast-to-noise ratio (CNR). In the case of an ideal scatter correction, the CNR is reduced even more, but contrast and CNR can be restored by an additional x-ray dose. With a 32-slice single-source CT (z overage of 20 mm) taken as a reference, a corresponding dual-source CT requires 7% more dose to maintain the same CNR. A CT system with a z coverage of 40, 80, and 160 mm requires 8%, 23%, and 54% more dose in a single-source configuration, respectively, and 20%, 47%, and 102% more dose in a dual-source configuration, respectively. In conclusion, a dual-source CT is comparable to a single-source CT with twice the z coverage concerning image degradation by scatter.

Entities:  

Mesh:

Year:  2008        PMID: 18293587     DOI: 10.1118/1.2820901

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT.

Authors:  Dimitrios Lazos; Jeffrey F Williamson
Journal:  Med Phys       Date:  2010-10       Impact factor: 4.071

2.  Quantifying cross-scatter contamination in biplane fluoroscopy motion analysis systems.

Authors:  Janelle A Cross; Ben McHenry; Taly Gilat Schmidt
Journal:  J Med Imaging (Bellingham)       Date:  2015-10-23

3.  Noise suppression in scatter correction for cone-beam CT.

Authors:  Lei Zhu; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

4.  Scatter correction for cone-beam CT in radiation therapy.

Authors:  Lei Zhu; Yaoqin Xie; Jing Wang; Lei Xing
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

5.  Quest for the ultimate cardiac CT scanner.

Authors:  Paul FitzGerald; Peter Edic; Hewei Gao; Yannan Jin; Jiao Wang; Ge Wang; Bruno De Man
Journal:  Med Phys       Date:  2017-07-17       Impact factor: 4.071

6.  Targeted dual-energy single-source CT for characterisation of urinary calculi: experimental and clinical experience.

Authors:  Matthias Eiber; Konstantin Holzapfel; Markus Frimberger; Michael Straub; Heike Schneider; Ernst J Rummeny; Martin Dobritz; Armin Huber
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

7.  Learning-based synthetic dual energy CT imaging from single energy CT for stopping power ratio calculation in proton radiation therapy.

Authors:  Serdar Charyyev; Tonghe Wang; Yang Lei; Beth Ghavidel; Jonathan J Beitler; Mark McDonald; Walter J Curran; Tian Liu; Jun Zhou; Xiaofeng Yang
Journal:  Br J Radiol       Date:  2021-10-28       Impact factor: 3.039

8.  Detection of ischaemic myocardial lesions with coronary CT angiography and adenosine-stress dynamic perfusion imaging using a 128-slice dual-source CT: diagnostic performance in comparison with cardiac MRI.

Authors:  S M Kim; J-H Choi; S-A Chang; Y H Choe
Journal:  Br J Radiol       Date:  2013-10-04       Impact factor: 3.039

9.  Methods to address metal artifacts in post-processed CT images - A do-it-yourself guide for orthopedic surgeons.

Authors:  Siddhartha Sharma; Aditya Kaushal; Sandeep Patel; Vishal Kumar; Mahesh Prakash; Dhillon Mandeep
Journal:  J Clin Orthop Trauma       Date:  2021-07-01

10.  Reduction of metal artifact in single photon-counting computed tomography by spectral-driven iterative reconstruction technique.

Authors:  Radin A Nasirudin; Kai Mei; Petar Penchev; Petar Panchev; Andreas Fehringer; Franz Pfeiffer; Ernst J Rummeny; Martin Fiebich; Peter B Noël
Journal:  PLoS One       Date:  2015-05-08       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.