Literature DB >> 24096592

Detection of ischaemic myocardial lesions with coronary CT angiography and adenosine-stress dynamic perfusion imaging using a 128-slice dual-source CT: diagnostic performance in comparison with cardiac MRI.

S M Kim1, J-H Choi, S-A Chang, Y H Choe.   

Abstract

OBJECTIVE: We assessed the diagnostic performance of adenosine-stress dynamic CT perfusion (ASDCTP) imaging and coronary CT angiography (CCTA) for the detection of ischaemic myocardial lesions using 128-slice dual-source CT compared with that of 1.5 T cardiac MRI.
METHODS: This prospective study included 33 patients (61±8 years, 82% male) with suspected coronary artery diseases who underwent ASDCTP imaging and adenosine-stress cardiac MRI. Two investigators independently evaluated ASDCTP images in correlation with significant coronary stenosis on CCTA using two different thresholds of 50% and 70% diameter stenosis. Hypoattenuated myocardial lesions on ASDCTP associated with significant coronary stenoses on CCTA were regarded as true perfusion defects. All estimates of diagnostic performance were calculated and compared with those of cardiac MRI.
RESULTS: With use of a threshold of 50% diameter stenosis on CCTA, the diagnostic estimates per-myocardial segment were as follows: sensitivity, 81% [95% confidence interval (CI): 70-92%]; specificity, 94% (95% CI: 92-96%); and accuracy 93% (95% CI: 91-95%). With use of a threshold of 70%, the diagnostic estimates were as follows: sensitivity, 48% (95% CI: 34-62%); specificity, 99% (95% CI: 98-100%); and accuracy, 94% (95% CI: 92-96%).
CONCLUSION: Dynamic CTP using 128-slice dual-source CT enables the assessment of the physiological significance of coronary artery lesions with high diagnostic accuracy in patients with clinically suspected coronary artery disease. ADVANCES IN KNOWLEDGE: Combined CCTA and ASDCTP yielded high accuracy in the detection of perfusion defects regardless of the threshold of significant coronary stenosis.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 24096592      PMCID: PMC3856549          DOI: 10.1259/bjr.20130481

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  31 in total

1.  Radiation exposure to patients in a multicenter coronary angiography trial (CORE 64).

Authors:  Jacob Geleijns; Raoul M S Joemai; Marc Dewey; Albert de Roos; Maria Zankl; Alfonso Calzado Cantera; Marçal Salvadó Artells
Journal:  AJR Am J Roentgenol       Date:  2011-05       Impact factor: 3.959

2.  Quantitative whole heart stress perfusion CT imaging as noninvasive assessment of hemodynamics in coronary artery stenosis: preliminary animal experience.

Authors:  Andreas H Mahnken; Ernst Klotz; Hubertus Pietsch; Bernhard Schmidt; Thomas Allmendinger; Ulrike Haberland; Willi A Kalender; Thomas Flohr
Journal:  Invest Radiol       Date:  2010-06       Impact factor: 6.016

3.  Adenosine stress high-pitch 128-slice dual-source myocardial computed tomography perfusion for imaging of reversible myocardial ischemia: comparison with magnetic resonance imaging.

Authors:  Gudrun Feuchtner; Robert Goetti; André Plass; Monika Wieser; Hans Scheffel; Christophe Wyss; Paul Stolzmann; Olivio Donati; Johannes Schnabl; Volkmar Falk; Hatem Alkadhi; Sebastian Leschka; Ricardo C Cury
Journal:  Circ Cardiovasc Imaging       Date:  2011-08-23       Impact factor: 7.792

4.  Myocardial perfusion imaging using adenosine-induced stress dual-energy computed tomography of the heart: comparison with cardiac magnetic resonance imaging and conventional coronary angiography.

Authors:  Sung Min Ko; Jin Woo Choi; Meong Gun Song; Je Kyoun Shin; Hyun Kun Chee; Hyun Woo Chung; Dong Hun Kim
Journal:  Eur Radiol       Date:  2010-07-25       Impact factor: 5.315

5.  Stress and rest dynamic myocardial perfusion imaging by evaluation of complete time-attenuation curves with dual-source CT.

Authors:  Kheng-Thye Ho; Kia-Chong Chua; Ernst Klotz; Christoph Panknin
Journal:  JACC Cardiovasc Imaging       Date:  2010-08

6.  Strategies for scatter correction in dual source CT.

Authors:  M Petersilka; K Stierstorfer; H Bruder; T Flohr
Journal:  Med Phys       Date:  2010-11       Impact factor: 4.071

7.  Detection of hemodynamically significant coronary artery stenosis: incremental diagnostic value of dynamic CT-based myocardial perfusion imaging.

Authors:  Fabian Bamberg; Alexander Becker; Florian Schwarz; Roy P Marcus; Martin Greif; Franz von Ziegler; Ron Blankstein; Udo Hoffmann; Wieland H Sommer; Verena S Hoffmann; Thorsten R C Johnson; Hans-Christoph R Becker; Bernd J Wintersperger; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Radiology       Date:  2011-09       Impact factor: 11.105

8.  Comparison of the extent and severity of myocardial perfusion defects measured by CT coronary angiography and SPECT myocardial perfusion imaging.

Authors:  Balaji K Tamarappoo; Damini Dey; Ryo Nakazato; Haim Shmilovich; Thomas Smith; Victor Y Cheng; Louise E J Thomson; Sean W Hayes; John D Friedman; Guido Germano; Piotr J Slomka; Daniel S Berman
Journal:  JACC Cardiovasc Imaging       Date:  2010-10

9.  Accuracy of dynamic computed tomography adenosine stress myocardial perfusion imaging in estimating myocardial blood flow at various degrees of coronary artery stenosis using a porcine animal model.

Authors:  Fabian Bamberg; Rabea Hinkel; Florian Schwarz; Torleif A Sandner; Elisabeth Baloch; Roy Marcus; Alexander Becker; Christian Kupatt; Bernd J Wintersperger; Thorsten R Johnson; Daniel Theisen; Ernst Klotz; Maximilian F Reiser; Konstantin Nikolaou
Journal:  Invest Radiol       Date:  2012-01       Impact factor: 6.016

10.  Adenosine stress 64- and 256-row detector computed tomography angiography and perfusion imaging: a pilot study evaluating the transmural extent of perfusion abnormalities to predict atherosclerosis causing myocardial ischemia.

Authors:  Richard T George; Armin Arbab-Zadeh; Julie M Miller; Kakuya Kitagawa; Hyuk-Jae Chang; David A Bluemke; Lewis Becker; Omair Yousuf; John Texter; Albert C Lardo; João A C Lima
Journal:  Circ Cardiovasc Imaging       Date:  2009-03-31       Impact factor: 7.792

View more
  7 in total

1.  Influence of scan technique on intracoronary transluminal attenuation gradient in coronary CT angiography using 128-slice dual source CT: multi-beat versus one-beat scan.

Authors:  Hae Jin Kim; Sung Mok Kim; Jin-Ho Choi; Yeon Hyeon Choe
Journal:  Int J Cardiovasc Imaging       Date:  2017-02-01       Impact factor: 2.357

Review 2.  CT myocardial perfusion imaging: current status and future perspectives.

Authors:  Dong Hyun Yang; Young-Hak Kim
Journal:  Int J Cardiovasc Imaging       Date:  2017-03-09       Impact factor: 2.357

3.  Evaluation of dual energy computed tomography iodine mapping within the myocardial blood pool for detection of acute myocardial infarction: correlation with histopathological findings in a porcine model.

Authors:  Kai Sun; Ruijuan Han; Ruiping Zhao; Shuancheng Bai; Junyan Wang; Jiang Hu; Bin Lu
Journal:  Br J Radiol       Date:  2018-05-11       Impact factor: 3.039

Review 4.  CAD-RADS - a new clinical decision support tool for coronary computed tomography angiography.

Authors:  Borek Foldyna; Bálint Szilveszter; Jan-Erik Scholtz; Dahlia Banerji; Pál Maurovich-Horvat; Udo Hoffmann
Journal:  Eur Radiol       Date:  2017-11-07       Impact factor: 5.315

5.  Regadenoson-Stress Dynamic Myocardial Perfusion Improves Diagnostic Performance of CT Angiography in Assessment of Intermediate Coronary Artery Stenosis in Asymptomatic Patients.

Authors:  Jan Baxa; Milan Hromádka; Jakub Šedivý; Lucie Štěpánková; Jiří Moláček; Bernhard Schmidt; Thomas Flohr; Jiří Ferda
Journal:  Biomed Res Int       Date:  2015-07-05       Impact factor: 3.411

6.  Diagnostic accuracy of coronary CT angiography combined with dual-energy myocardial perfusion imaging for detection of myocardial infarction.

Authors:  Ruijuan Han; Kai Sun; Bin Lu; Ruiping Zhao; Kuncheng Li; Xinchun Yang
Journal:  Exp Ther Med       Date:  2017-05-22       Impact factor: 2.447

7.  Non-invasive coronary physiology based on computational analysis of intracoronary transluminal attenuation gradient.

Authors:  Yong Gyun Bae; Seung Tae Hwang; Huan Han; Sung Mok Kim; Hyung-Yoon Kim; Il Park; Joo Myung Lee; Young-June Moon; Jin-Ho Choi
Journal:  Sci Rep       Date:  2018-03-16       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.