Alumina-on-alumina bearings for THA have markedly improved in mechanical properties through advances in technology; however, alumina fracture is still a concern. We retrospectively reviewed 77 patients (82 hips) with cemented alumina-on-alumina THAs to identify factors relating to alumina failure. The mean age of the patients at surgery was 63 years. The prostheses had a cemented polyethylene-backed acetabular component with an alumina inlay and a 28-mm alumina head. Revision surgery was performed because of alumina inlay failure in four hips (three fractures and one dissociation; 5.6%), deep infection in two, and recurrent dislocation in one. The 8-year survival rate was 90.7% with revision for any reason and 94.4% with revision for alumina failure as the end point. There were no differences in age, body mass index, gender, mobility, function, abduction angle, or size of component among the four hips with alumina failure and the remaining 68 hips without it; however, radiolucent lines in the sockets were more apparent in four cases with alumina inlay failure. This alumina-on-alumina THA thus yielded unsatisfactory medium-term results because we observed a high rate of catastrophic alumina inlay failure.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18288546      PMCID: PMC2311492          DOI: 10.1007/s11999-008-0168-9

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  32 in total

1.  Functional results of hip arthroplasty with acrylic prosthesis.

Authors:  R M D'AUBIGNE; M POSTEL
Journal:  J Bone Joint Surg Am       Date:  1954-06       Impact factor: 5.284

2.  Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis.

Authors:  R S Nizard; L Sedel; P Christel; A Meunier; M Soudry; J Witvoet
Journal:  Clin Orthop Relat Res       Date:  1992-09       Impact factor: 4.176

3.  Early radiographic results comparing cemented and cementless total hip arthroplasty.

Authors:  B D Mulliken; N Nayak; R B Bourne; C H Rorabeck; R Bullas
Journal:  J Arthroplasty       Date:  1996-01       Impact factor: 4.757

4.  Mittelmeier ceramic total hip arthroplasty. A retrospective study.

Authors:  J F O'Leary; T H Mallory; T J Kraus; A V Lombardi; C L Lye
Journal:  J Arthroplasty       Date:  1988       Impact factor: 4.757

5.  Massive osteolysis after ceramic on ceramic total hip arthroplasty. A case report.

Authors:  P Z Wirganowicz; B J Thomas
Journal:  Clin Orthop Relat Res       Date:  1997-05       Impact factor: 4.176

6.  The measurement of migration of the acetabular component of hip prostheses.

Authors:  D Nunn; M A Freeman; P F Hill; S J Evans
Journal:  J Bone Joint Surg Br       Date:  1989-08

7.  Long-term results of uncemented alumina acetabular implants.

Authors:  M Boehler; K Knahr; H Plenk; A Walter; M Salzer; V Schreiber
Journal:  J Bone Joint Surg Br       Date:  1994-01

8.  Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study.

Authors:  Jeong Joon Yoo; Young-Min Kim; Kang Sup Yoon; Kyung-Hoi Koo; Won Seok Song; Hee Joong Kim
Journal:  J Bone Joint Surg Am       Date:  2005-03       Impact factor: 5.284

9.  Osteolysis in association with a total hip arthroplasty with ceramic bearing surfaces.

Authors:  T R Yoon; S M Rowe; S T Jung; K J Seon; W J Maloney
Journal:  J Bone Joint Surg Am       Date:  1998-10       Impact factor: 5.284

10.  Alumina-alumina hip replacement in patients younger than 50 years old.

Authors:  L Sedel; R S Nizard; L Kerboull; J Witvoet
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

View more
  7 in total

1.  Causes of failure of ceramic-on-ceramic and metal-on-metal hip arthroplasties.

Authors:  Manny Porat; Javad Parvizi; Peter F Sharkey; Keith R Berend; Adolph V Lombardi; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

Review 2.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

4.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

Review 5.  The incidence of implant fractures after total hip arthroplasty.

Authors:  Patrick Sadoghi; Wolfram Pawelka; Michael C Liebensteiner; Alexandra Williams; Andreas Leithner; Gerold Labek
Journal:  Int Orthop       Date:  2014-01       Impact factor: 3.075

6.  Nine year follow-up of a ceramic-on-ceramic bearing total hip arthroplasty utilizing a layered monoblock acetabular component.

Authors:  David Mayor; Savan Patel; Clayton Perry; Norman Walter; Stephen Burton; Theresa Atkinson
Journal:  Iowa Orthop J       Date:  2014

7.  Optimal Design of Ceramic Based Hip Implant Composites Using Hybrid AHP-MOORA Approach.

Authors:  Tej Singh; Chandramani Goswami; Amar Patnaik; László Lendvai
Journal:  Materials (Basel)       Date:  2022-05-26       Impact factor: 3.748

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.