Literature DB >> 25028335

Experience with sandwich liner and its high rate of failure.

John Junghun Shin1, Ji-Soo Shin, Jae-Hyun Kim, Sung Kwan Hwang.   

Abstract

BACKGROUND: Composite ceramic with polyethylene backing was introduced to enhance the quality of ceramic articulation, but the liner's high rate of ceramic fracture has brought serious concern. In this study, the authors investigated the failure rate of sandwich liner in long-term follow-up patients at single institution.
METHODS: In this series, we retrospectively reviewed 134 patients (143 hips), and six patients (6.2%) were found to have liner fracture. They were compared to nonfracture patients to identify the associating factors. General patient characteristics were obtained through review of charts. All patients were implanted with SPH Contact acetabular cup and sandwich liner. Function (Harris hip score) and activity (Devane score) were recorded preoperatively and at final follow-up. Radiologically, inclination and abduction angles were measured for comparison.
RESULTS: The study did not show any statistical differences between fracture and nonfracture groups in age, weight or body mass index. Side, type of stem used and radiologic parameters were not also significantly different. The operation had significantly improved function and activity postoperatively in both groups, but no statistical significance was noted between the two groups exception to preoperative Harris hip score. On inspection, retrieved ceramic heads and liners showed substantial metal transfer on their surfaces, and linear wears were evident on the ceramic heads.
CONCLUSIONS: Compared to other studies, our series also experienced high rate of sandwich liner fracture. Though its use was generally discontinued, it is worrisome to note that failure rate of the liner will substantially increase over time.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 25028335     DOI: 10.1007/s00590-014-1503-3

Source DB:  PubMed          Journal:  Eur J Orthop Surg Traumatol        ISSN: 1633-8065


  30 in total

1.  Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup.

Authors:  Masahiro Hasegawa; Akihiro Sudo; Hitoshi Hirata; Atsumasa Uchida
Journal:  J Arthroplasty       Date:  2003-08       Impact factor: 4.757

Review 2.  Concerns about ceramics in THA.

Authors:  Robert L Barrack; Corey Burak; Harry B Skinner
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

3.  Intrapelvic protrusion of the ceramic head resulting from forte ceramic liner fracture without a significant trauma: a case report.

Authors:  Halil Ibrahim Bekler; Yiğit Erdağ; Murat Ozşahin
Journal:  Eklem Hastalik Cerrahisi       Date:  2013

4.  High rate of ceramic sandwich liner fracture.

Authors:  Ronny Lopes; Jean M Philippeau; Norbert Passuti; François Gouin
Journal:  Clin Orthop Relat Res       Date:  2012-03-02       Impact factor: 4.176

5.  Ten-year results after cementless THA with a sandwich-type alumina ceramic bearing.

Authors:  Youn-Soo Park; Se-Jun Park; Seung-Jae Lim
Journal:  Orthopedics       Date:  2010-11-02       Impact factor: 1.390

Review 6.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

7.  Extremely high fracture rate of a modular acetabular component with a sandwich polyethylene ceramic insertion for THA: a preliminary report.

Authors:  Jörn Kircher; Rainer Bader; Bettina Schroeder; Wolfram Mittelmeier
Journal:  Arch Orthop Trauma Surg       Date:  2008-06-21       Impact factor: 3.067

8.  Revision of ceramic head fracture after third generation ceramic-on-ceramic total hip arthroplasty.

Authors:  Kyung-Hoi Koo; Yong-Chan Ha; Shin-Yoon Kim; Kang-Sup Yoon; Byung-Woo Min; Sang-Rim Kim
Journal:  J Arthroplasty       Date:  2013-05-14       Impact factor: 4.757

9.  Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup.

Authors:  Dragos Popescu; X Gallart; S Garcia; G Bori; X Tomas; J Riba
Journal:  Arch Orthop Trauma Surg       Date:  2007-12-08       Impact factor: 3.067

Review 10.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.