Literature DB >> 1516329

Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis.

R S Nizard1, L Sedel, P Christel, A Meunier, M Soudry, J Witvoet.   

Abstract

In the first 187 consecutive alumina-alumina combination hip arthroplasties performed from 1977 to 1979, both components were cemented with conventional techniques. At ten-year follow-up evaluation, 87 patients were reviewed or interviewed by telephone, 37 were dead, 39 were lost to follow-up evaluation, and 24 failures were reoperated on before the end of ten years. The major cause of failure was aseptic loosening of the acetabular component (15 failures). Fracture of the socket and of the femoral head occurred in five patients in this series. However, these complications were not seen with components manufactured after 1979. At the end of ten years, survivorship analysis depicted a 82.59% survival rate when reoperation was considered as failure and a 88.57% rate when reoperation for aseptic loosening was considered as failure. The femoral component had a 99.16% survival rate and the acetabular component had an 88.57% survival rate when reoperation for aseptic loosening was considered as failure. Age, appearance of a two- or three-zone demarcation at the intermediate follow-up evaluation, and outer diameter of the acetabular component were the major parameters influencing the results. Better results observed in the population younger than 50 years of age may be related to the small amount of wear debris produced by the alumina-alumina combination. This combination in hip prosthesis is secure, but should be implanted in young and active patients; the outer diameter of the acetabular component must be at least 50 mm. The major problem that remains is the socket's fixation. It could be improved by a design modification, by choosing another mode of fixation, or both.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1516329

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  23 in total

1.  An economic model to estimate the relative costs over 20 years of different hip prostheses.

Authors:  K Baxter; G Bevan
Journal:  J Epidemiol Community Health       Date:  1999-09       Impact factor: 3.710

Review 2.  Survival of hard-on-hard bearings in total hip arthroplasty: a systematic review.

Authors:  Michael G Zywiel; Siraj A Sayeed; Aaron J Johnson; Thomas P Schmalzried; Michael A Mont
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

3.  Clinical results of posterior cruciate ligament retaining TKA with alumina ceramic condylar prosthesis: comparison to Co-Cr alloy prosthesis.

Authors:  Tokifumi Majima; Kazunori Yasuda; Hidenobu Tago; Yoshimitu Aoki; Akio Minami
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-11-03       Impact factor: 4.342

4.  Experience with sandwich liner and its high rate of failure.

Authors:  John Junghun Shin; Ji-Soo Shin; Jae-Hyun Kim; Sung Kwan Hwang
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-07-16

5.  The ceramic cup type Lindenhof. Results 10-14 years after implantation.

Authors:  H Gierse; B Maaz; C Hofer; S Gruner
Journal:  Arch Orthop Trauma Surg       Date:  1996       Impact factor: 3.067

Review 6.  Thirty years of experience with alumina-on-alumina bearings in total hip arthroplasty.

Authors:  Didier Hannouche; Amine Zaoui; Frédéric Zadegan; Laurent Sedel; Rémy Nizard
Journal:  Int Orthop       Date:  2010-12-30       Impact factor: 3.075

7.  Alumina inlay failure in cemented polyethylene-backed total hip arthroplasty.

Authors:  Kentaro Iwakiri; Hiroyoshi Iwaki; Yukihide Minoda; Hirotsugu Ohashi; Kunio Takaoka
Journal:  Clin Orthop Relat Res       Date:  2008-02-21       Impact factor: 4.176

Review 8.  [Fracture of the ceramic head in total hip prosthesis. Apropos of 2 cases].

Authors:  P Mangione; X Pascarel; B Vinciguerra; J L Honton
Journal:  Int Orthop       Date:  1994       Impact factor: 3.075

9.  Effect of particles and interface conditions on fibrous tissue interposition between bone and implant. A particle challenge model in rabbit.

Authors:  H Ohashi; A Kobayashi; Y Kadoya; Y Yamano; H Oonishi; H Iwaki
Journal:  J Mater Sci Mater Med       Date:  2000-04       Impact factor: 3.896

10.  18 years of results with cemented primary hip prostheses in the Norwegian Arthroplasty Register: concerns about some newer implants.

Authors:  Birgitte Espehaug; Ove Furnes; Lars B Engesaeter; Leif I Havelin
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.