Literature DB >> 25328464

Nine year follow-up of a ceramic-on-ceramic bearing total hip arthroplasty utilizing a layered monoblock acetabular component.

David Mayor1, Savan Patel1, Clayton Perry1, Norman Walter1, Stephen Burton1, Theresa Atkinson2.   

Abstract

INTRODUCTION: Early ceramic bearing systems in total hip arthoplasty (THA) sought to provide long term wear improvement over traditional metal on polyethylene systems. However, previous designs exhibited fractures of the ceramic acetabular liner, leading to the development of the Implex Hedrocel ceramic bearing THA system where the ceramic liner was supported on a layer of polyethylene intended to transition liner loads to the metal shell, a so-called "sandwich" design. Unfortunately, the device trial was stopped to further enrollment when liner fractures were reported. The current study examines nearly 10-year follow-up on 28 devices implanted by two surgeons at one institution in order to document ceramic bearing system performance over a longer time period.
METHODS: Radiographic and patient reported outcomes, in the form of Harris Hip Scores (HHS) and 12-Item Short Form Health Survey (sF-12), were collected.
RESULTS: During the study period two cups were replaced, one at three years and a second at seven years. At the five year follow-up HHS were similar to those reported in the literature for devices with traditional metal-on-polyethylene bearing surfaces and for other sandwich ceramic bearing designs. At the nine year follow-up, the HHS had not changed significantly and SF-12 scores measuring overall physical and mental health were higher than age matched national norms (p<0.001). There were no signs of cup migration, stem subsidence, osteolysis or cup loosening at any time up to the last follow-up in this patient cohort. The 89% survivorship rate and device revisions due to delamination of the liner observed in this group were similar to those reported earlier for this device and for other "sandwich design" ceramic bearing systems. DISCUSSION: This cohort did not exhibit new failure modes and HHS and SF-12 scores indicated high functionality for the majority of patients. These data suggest that a focus on preventing ceramic liner fracture through design and/or materials improvements may result in a device with long-term functionality.

Entities:  

Mesh:

Year:  2014        PMID: 25328464      PMCID: PMC4127741     

Source DB:  PubMed          Journal:  Iowa Orthop J        ISSN: 1541-5457


  20 in total

1.  Fractures of a sandwich ceramic liner at ten year follow-up.

Authors:  Anthony Viste; Julien Chouteau; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2011-10-20       Impact factor: 3.075

2.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

3.  A 12-Item Short-Form Health Survey: construction of scales and preliminary tests of reliability and validity.

Authors:  J Ware; M Kosinski; S D Keller
Journal:  Med Care       Date:  1996-03       Impact factor: 2.983

4.  High rate of ceramic sandwich liner fracture.

Authors:  Ronny Lopes; Jean M Philippeau; Norbert Passuti; François Gouin
Journal:  Clin Orthop Relat Res       Date:  2012-03-02       Impact factor: 4.176

5.  Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation.

Authors:  W H Harris
Journal:  J Bone Joint Surg Am       Date:  1969-06       Impact factor: 5.284

6.  "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening.

Authors:  T A Gruen; G M McNeice; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1979-06       Impact factor: 4.176

7.  Failure rates of stemmed metal-on-metal hip replacements: analysis of data from the National Joint Registry of England and Wales.

Authors:  Alison J Smith; Paul Dieppe; Kelly Vernon; Martyn Porter; Ashley W Blom
Journal:  Lancet       Date:  2012-03-13       Impact factor: 79.321

8.  Mid-term results of third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty: a ten-year minimum follow-up.

Authors:  Eric Yeung; Paul Thornton Bott; Rishi Chana; Mark P Jackson; Ian Holloway; William L Walter; Bernard A Zicat; William K Walter
Journal:  J Bone Joint Surg Am       Date:  2012-01-18       Impact factor: 5.284

9.  Health-related quality of life after total knee or hip replacement for osteoarthritis: a 7-year prospective study.

Authors:  O Bruyère; O Ethgen; A Neuprez; B Zégels; Ph Gillet; J-P Huskin; J-Y Reginster
Journal:  Arch Orthop Trauma Surg       Date:  2012-07-28       Impact factor: 3.067

10.  High survival in young patients using a second generation uncemented total hip replacement.

Authors:  Marcus R Streit; Kerstin Schröder; Matthias Körber; Christian Merle; Tobias Gotterbarm; Volker Ewerbeck; Peter R Aldinger
Journal:  Int Orthop       Date:  2011-11-24       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.