Literature DB >> 18287556

Sensitivity of inferior colliculus neurons to interaural time differences in the envelope versus the fine structure with bilateral cochlear implants.

Zachary M Smith1, Bertrand Delgutte.   

Abstract

Bilateral cochlear implantation seeks to improve hearing by taking advantage of the binaural processing of the central auditory system. Cochlear implants typically encode sound in each spectral channel by amplitude modulating (AM) a fixed-rate pulse train, thus interaural time differences (ITD) are only delivered in the envelope. We investigated the ITD sensitivity of inferior colliculus (IC) neurons with sinusoidally AM pulse trains. ITD was introduced independently to the AM and/or carrier pulses to measure the relative efficacy of envelope and fine structure for delivering ITD information. We found that many IC cells are sensitive to ITD in both the envelope (ITD(env)) and fine structure (ITD(fs)) for appropriate modulation frequencies and carrier rates. ITD(env) sensitivity was generally similar to that seen in normal-hearing animals with AM tones. ITD(env) tuning generally improved with increasing modulation frequency up to the maximum modulation frequency that elicited a sustained response in a neuron (tested </=160 Hz). ITD(fs) sensitivity was present in about half the neurons for 1,000 pulse/s (pps) carriers and was nonexistent at 5,000 pps. The neurons that were sensitive to ITD(fs) at 1,000 pps were those that showed the best ITD sensitivity to low-rate pulse trains. Overall, the best ITD sensitivity was found for ITD contained in the fine structure of a moderate rate AM pulse train (1,000 pps). These results suggest that the interaural timing of current pulses should be accurately controlled in a bilateral cochlear implant processing strategy that provides salient ITD cues.

Entities:  

Mesh:

Year:  2008        PMID: 18287556      PMCID: PMC2570106          DOI: 10.1152/jn.00751.2007

Source DB:  PubMed          Journal:  J Neurophysiol        ISSN: 0022-3077            Impact factor:   2.714


  61 in total

1.  Organization of binaural excitatory and inhibitory inputs to the inferior colliculus from the superior olive.

Authors:  William C Loftus; Deborah C Bishop; Richard L Saint Marie; Douglas L Oliver
Journal:  J Comp Neurol       Date:  2004-05-03       Impact factor: 3.215

2.  A new approach to comparing binaural masking level differences at low and high frequencies.

Authors:  S van de Par; A Kohlrausch
Journal:  J Acoust Soc Am       Date:  1997-03       Impact factor: 1.840

3.  Responses of neurons in the dorsal nucleus of the lateral lemniscus of cat to binaural tonal stimulation.

Authors:  J F Brugge; D J Anderson; L M Aitkin
Journal:  J Neurophysiol       Date:  1970-05       Impact factor: 2.714

4.  Binaural interaction in the cat superior olive S segment.

Authors:  J C Boudreau; C Tsuchitani
Journal:  J Neurophysiol       Date:  1968-05       Impact factor: 2.714

5.  Response of binaural neurons of dog superior olivary complex to dichotic tonal stimuli: some physiological mechanisms of sound localization.

Authors:  J M Goldberg; P B Brown
Journal:  J Neurophysiol       Date:  1969-07       Impact factor: 2.714

6.  Envelope coding in the lateral superior olive. I. Sensitivity to interaural time differences.

Authors:  P X Joris; T C Yin
Journal:  J Neurophysiol       Date:  1995-03       Impact factor: 2.714

7.  Speech recognition with primarily temporal cues.

Authors:  R V Shannon; F G Zeng; V Kamath; J Wygonski; M Ekelid
Journal:  Science       Date:  1995-10-13       Impact factor: 47.728

8.  Enhancement of neural synchronization in the anteroventral cochlear nucleus. I. Responses to tones at the characteristic frequency.

Authors:  P X Joris; L H Carney; P H Smith; T C Yin
Journal:  J Neurophysiol       Date:  1994-03       Impact factor: 2.714

9.  Interaction of excitation and inhibition in processing of pure tone and amplitude-modulated stimuli in the medial superior olive of the mustached bat.

Authors:  B Grothe
Journal:  J Neurophysiol       Date:  1994-02       Impact factor: 2.714

10.  Temporal resolution of neurons in cat inferior colliculus to intracochlear electrical stimulation: effects of neonatal deafening and chronic stimulation.

Authors:  R Snyder; P Leake; S Rebscher; R Beitel
Journal:  J Neurophysiol       Date:  1995-02       Impact factor: 2.714

View more
  13 in total

1.  Models of brainstem responses to bilateral electrical stimulation.

Authors:  H Steven Colburn; Yoojin Chung; Yi Zhou; Andrew Brughera
Journal:  J Assoc Res Otolaryngol       Date:  2008-10-22

2.  Neural ITD coding with bilateral cochlear implants: effect of binaurally coherent jitter.

Authors:  Kenneth E Hancock; Yoojin Chung; Bertrand Delgutte
Journal:  J Neurophysiol       Date:  2012-05-16       Impact factor: 2.714

3.  Sound frequency-invariant neural coding of a frequency-dependent cue to sound source location.

Authors:  Heath G Jones; Andrew D Brown; Kanthaiah Koka; Jennifer L Thornton; Daniel J Tollin
Journal:  J Neurophysiol       Date:  2015-05-13       Impact factor: 2.714

4.  Modeling binaural responses in the auditory brainstem to electric stimulation of the auditory nerve.

Authors:  Yoojin Chung; Bertrand Delgutte; H Steven Colburn
Journal:  J Assoc Res Otolaryngol       Date:  2014-10-28

5.  Temporal Envelope Coding by Inferior Colliculus Neurons with Cochlear Implant Stimulation.

Authors:  Kenneth E Hancock; Yoojin Chung; Martin F McKinney; Bertrand Delgutte
Journal:  J Assoc Res Otolaryngol       Date:  2017-07-17

6.  Sensitivity of bilateral cochlear implant users to fine-structure and envelope interaural time differences.

Authors:  Victor A Noel; Donald K Eddington
Journal:  J Acoust Soc Am       Date:  2013-04       Impact factor: 1.840

7.  The effect of envelope modulations on binaural processing.

Authors:  Matthew J Goupell; Stephen Fong; Olga Stakhovskaya
Journal:  Hear Res       Date:  2019-05-21       Impact factor: 3.208

8.  Envelope contributions to the representation of interaural time difference in the forebrain of barn owls.

Authors:  Philipp Tellers; Jessica Lehmann; Hartmut Führ; Hermann Wagner
Journal:  J Neurophysiol       Date:  2017-07-05       Impact factor: 2.714

9.  Neural Coding of Interaural Time Differences with Bilateral Cochlear Implants in Unanesthetized Rabbits.

Authors:  Yoojin Chung; Kenneth E Hancock; Bertrand Delgutte
Journal:  J Neurosci       Date:  2016-05-18       Impact factor: 6.167

10.  Bilateral cochlear implantation in the ferret: a novel animal model for behavioral studies.

Authors:  Douglas E H Hartley; Tara Vongpaisal; Jin Xu; Robert K Shepherd; Andrew J King; Amal Isaiah
Journal:  J Neurosci Methods       Date:  2010-05-31       Impact factor: 2.390

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.