The effect of haematocrit on reagent strip tests for glucose.

K Wiener1.   

Abstract

Four blood glucose reagent strips (BM-Test 1-44, Glucostix, Hypoguard GA, and Exactech), used in conjunction with measuring devices produced by the same manufacturer, were investigated with respect to the influence of haematocrit. The erythrocytes and plasma of fresh blood samples were separated, then remixed in different proportions to achieve a range of haematocrit values and the resulting specimens subjected to glucose assay. All the strip tests showed some influence of haematocrit, low haematocrits producing higher glucose results and vice versa, but some were much more affected than others. The Hypoguard GA was most affected and the BM-Test 1-44 least. In the worst case, glucose results differed by 49% from one end of the normal adult haematocrit range to the other.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1827405     DOI: 10.1111/j.1464-5491.1991.tb01566.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  8 in total

Review 1.  Factors affecting blood glucose monitoring: sources of errors in measurement.

Authors:  Barry H Ginsberg
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

2.  Comparison of two cotside methods for the detection of hypoglycaemia among neonates in Nepal.

Authors:  M Ellis; D S Manandhar; N Manandhar; J M Land; N Patel; A M de L Costello
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-09       Impact factor: 5.747

3.  Performance variability of seven commonly used self-monitoring of blood glucose systems: clinical considerations for patients and providers.

Authors:  Ronald L Brazg; Leslie J Klaff; Christopher G Parkin
Journal:  J Diabetes Sci Technol       Date:  2013-01-01

4.  Utility of point-of-care vs reference laboratory testing for the evaluation of glucose levels.

Authors:  O M Andriankaja; F J Muñoz-Torres; J L Vergara; C M Pérez; K Joshipura
Journal:  Diabet Med       Date:  2019-03-01       Impact factor: 4.359

5.  A Simulation Study to Assess the Effect of Analytic Error on Neonatal Glucose Measurements Using the Canadian Pediatric Society Position Statement Action Thresholds.

Authors:  Mark Inman; Kayla Parker; Lannae Strueby; Andrew W Lyon; Martha E Lyon
Journal:  J Diabetes Sci Technol       Date:  2019-11-06

6.  Comparison of two reflectance photometers in the assessment of neonatal hypoglycaemia.

Authors:  P Kirkham; A Watkins
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-11       Impact factor: 5.747

7.  Blood glucose reagent strip tests in the operating room: influence of hematocrit, partial pressure of oxygen, and blood glucose level--a comparison of the BM-test 1-44, BM-Accutest, and Satellite G reagent strip systems.

Authors:  M H Cross; D G Brown
Journal:  J Clin Monit       Date:  1996-01

8.  Design of an ELC resonator-based reusable RF microfluidic sensor for blood glucose estimation.

Authors:  Greeshmaja Govind; M Jaleel Akhtar
Journal:  Sci Rep       Date:  2020-11-02       Impact factor: 4.379

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.