Literature DB >> 18272700

Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates.

J H Glasson1, L H Guthrie, D J Nielsen, F A Bethell.   

Abstract

The findings from a preliminary assessment of a new instrument designed for the inoculation and spreading of specimens for microbiological analysis onto agar plates are described. The study found that the instrument was able to select full or biplates from a number of input cassettes, each containing different agar types. Samples were then inoculated by the instrument onto the agar surfaces and spread by a novel plastic applicator. Following this, the instrument labeled the plates and sorted them into a number of specified output stations. It was found that the instrument was able to inoculate and spread samples over a greater proportion of the agar plate surface than the manual loop-to-plate method. As a consequence, up to 44% more usable colonies were produced per plate from clinical specimens and standard cultures. Viable counts showed that the instrument was able to detect as few as 10(2) CFU/ml in fluids and also facilitated the enumeration of organisms, particularly in specimens such as urine.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18272700      PMCID: PMC2292914          DOI: 10.1128/JCM.01687-07

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Asymptomatic infections of the urinary tract.

Authors:  E H KASS
Journal:  Trans Assoc Am Physicians       Date:  1956

2.  Evaluation of an automated agar plate streaker.

Authors:  R C Tilton; R W Ryan
Journal:  J Clin Microbiol       Date:  1978-03       Impact factor: 5.948

3.  Accuracy of calibrated-loop transfer.

Authors:  A C Albers; R D Fletcher
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

4.  Diagnosis of coliform infection in acutely dysuric women.

Authors:  W E Stamm; G W Counts; K R Running; S Fihn; M Turck; K K Holmes
Journal:  N Engl J Med       Date:  1982-08-19       Impact factor: 91.245

5.  Comparison of Easy-Flow Copan Liquid Stuart's and Starplex Swab transport systems for recovery of fastidious aerobic bacteria.

Authors:  Cheryl Drake; Joan Barenfanger; Jerry Lawhorn; Steven Verhulst
Journal:  J Clin Microbiol       Date:  2005-03       Impact factor: 5.948

  5 in total
  10 in total

1.  Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

Authors:  Qute Choi; Hyun Jin Kim; Jong Wan Kim; Gye Cheol Kwon; Sun Hoe Koo
Journal:  J Clin Lab Anal       Date:  2018-01-04       Impact factor: 2.352

2.  First evaluation of the WASP, a new automated microbiology plating instrument.

Authors:  Paul P Bourbeau; Brandi Lynn Swartz
Journal:  J Clin Microbiol       Date:  2009-01-21       Impact factor: 5.948

3.  Comparison of five media for detection of extended-spectrum Beta-lactamase by use of the wasp instrument for automated specimen processing.

Authors:  P Grohs; B Tillecovidin; A Caumont-Prim; E Carbonnelle; N Day; I Podglajen; L Gutmann
Journal:  J Clin Microbiol       Date:  2013-05-22       Impact factor: 5.948

4.  Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation.

Authors:  Antony Croxatto; Klaas Dijkstra; Guy Prod'hom; Gilbert Greub
Journal:  J Clin Microbiol       Date:  2015-05-13       Impact factor: 5.948

5.  Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

Authors:  S Le Page; A van Belkum; C Fulchiron; R Huguet; D Raoult; J-M Rolain
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-06-20       Impact factor: 3.267

6.  An Overview on Novel Microbial Determination Methods in Pharmaceutical and Food Quality Control.

Authors:  Mahboob Nemati; Aliasghar Hamidi; Solmaz Maleki Dizaj; Vahid Javaherzadeh; Farzaneh Lotfipour
Journal:  Adv Pharm Bull       Date:  2016-09-25

Review 7.  Emerging technologies for the clinical microbiology laboratory.

Authors:  Blake W Buchan; Nathan A Ledeboer
Journal:  Clin Microbiol Rev       Date:  2014-10       Impact factor: 26.132

8.  Automated versus manual sample inoculations in routine clinical microbiology: a performance evaluation of the fully automated InoqulA instrument.

Authors:  P Froment; H Marchandin; P Vande Perre; B Lamy
Journal:  J Clin Microbiol       Date:  2013-12-18       Impact factor: 5.948

9.  First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

Authors:  Alexander Mischnik; Markus Mieth; Cornelius J Busch; Stefan Hofer; Stefan Zimmermann
Journal:  J Clin Microbiol       Date:  2012-06-12       Impact factor: 5.948

10.  Evaluation of the impact of automated specimen inoculation, using Previ Isola, on the quality of and technical time for stool cultures.

Authors:  Alexander Mischnik; Marlies Trampe; Stefan Zimmermann
Journal:  Ann Lab Med       Date:  2014-12-08       Impact factor: 3.464

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.