Literature DB >> 22692745

First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

Alexander Mischnik1, Markus Mieth, Cornelius J Busch, Stefan Hofer, Stefan Zimmermann.   

Abstract

Automation of plate streaking is ongoing in clinical microbiological laboratories, but evaluation for routine use is mostly open. In the present study, the recovery of microorganisms from the Previ Isola system plated polyurethane (PU) swab samples is compared to manually plated control viscose swab samples from wounds according to the CLSI procedure M40-A (quality control of microbiological transport systems). One hundred twelve paired samples (224 swabs) were analyzed. In 80/112 samples (71%), concordant culture results were obtained with the two methods. In 32/112 samples (29%), CFU recovery of microorganisms from the two methods was discordant. In 24 (75%) of the 32 paired samples with a discordant result, Previ Isola plated PU swabs were superior. In 8 (25%) of the 32 paired samples with a discordant result, control viscose swabs were superior. The quality of colony growth on culture media for further investigations was superior with Previ Isola inoculated plates compared to manual plating techniques. Gram stain results were concordant between the two methods in 62/112 samples (55%). In 50/112 samples (45%), the results of Gram staining were discordant between the two methods. In 34 (68%) of the 50 paired samples with discordant results, Gram staining of PU swabs was superior to that of control viscose swabs. In 16 (32%) of the 50 paired samples, Gram staining of control viscose swabs was superior to that of PU swabs. We report the first clinical evaluation of Previ Isola automated specimen inoculation for wound swab samples. This study suggests that use of an automated specimen inoculation system has good results with regard to CFU recovery, quality of Gram staining, and accuracy of diagnosis.

Entities:  

Mesh:

Year:  2012        PMID: 22692745      PMCID: PMC3421514          DOI: 10.1128/JCM.05501-11

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  12 in total

1.  Survival of aerobic and anaerobic bacteria in purulent clinical specimens maintained in the Copan Venturi Transystem and Becton Dickinson Port-a-Cul transport systems.

Authors:  D M Citron; Y A Warren; M K Hudspeth; E J Goldstein
Journal:  J Clin Microbiol       Date:  2000-02       Impact factor: 5.948

2.  Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.

Authors:  Gregory W King; Gary S Kath; Sal Siciliano; Neal Simpson; Prakash Masurekar; Jan Sigmund; Jon Polishook; Stephen Skwish; Gerald Bills; Olga Genilloud; Fernando Peláez; Jesus Martín; Claude Dufresne
Journal:  J Biomol Screen       Date:  2006-07-14

3.  Comparison of the Copan ESwab system with two Amies agar swab transport systems for maintenance of microorganism viability.

Authors:  Kenneth G Van Horn; Carol D Audette; Denise Sebeck; Kelly A Tucker
Journal:  J Clin Microbiol       Date:  2008-03-19       Impact factor: 5.948

4.  Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates.

Authors:  J H Glasson; L H Guthrie; D J Nielsen; F A Bethell
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

5.  First evaluation of the WASP, a new automated microbiology plating instrument.

Authors:  Paul P Bourbeau; Brandi Lynn Swartz
Journal:  J Clin Microbiol       Date:  2009-01-21       Impact factor: 5.948

6.  Comparison of two transport systems for recovery of aerobic and anaerobic bacteria from abscesses.

Authors:  I Brook
Journal:  J Clin Microbiol       Date:  1987-10       Impact factor: 5.948

7.  Factors contributing to loss of anaerobic bacteria in transit from the patient to the laboratory.

Authors:  J G Collee
Journal:  Infection       Date:  1980       Impact factor: 3.553

8.  Comparison of three transport systems (Starplex StarSwab II, the new Copan Vi-Pak Amies Agar Gel collection and transport swabs, and BBL Port-A-Cul) for maintenance of anaerobic and fastidious aerobic organisms.

Authors:  M Hindiyeh; V Acevedo; K C Carroll
Journal:  J Clin Microbiol       Date:  2001-01       Impact factor: 5.948

9.  Clinical evaluation of the Copan ESwab for methicillin-resistant Staphylococcus aureus detection and culture of wounds.

Authors:  V Saegeman; J Flamaing; J Muller; W E Peetermans; J Stuyck; J Verhaegen
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2011-02-06       Impact factor: 3.267

10.  Comparison of Easy-Flow Copan Liquid Stuart's and Starplex Swab transport systems for recovery of fastidious aerobic bacteria.

Authors:  Cheryl Drake; Joan Barenfanger; Jerry Lawhorn; Steven Verhulst
Journal:  J Clin Microbiol       Date:  2005-03       Impact factor: 5.948

View more
  18 in total

1.  Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

Authors:  Qute Choi; Hyun Jin Kim; Jong Wan Kim; Gye Cheol Kwon; Sun Hoe Koo
Journal:  J Clin Lab Anal       Date:  2018-01-04       Impact factor: 2.352

2.  Comparison of five media for detection of extended-spectrum Beta-lactamase by use of the wasp instrument for automated specimen processing.

Authors:  P Grohs; B Tillecovidin; A Caumont-Prim; E Carbonnelle; N Day; I Podglajen; L Gutmann
Journal:  J Clin Microbiol       Date:  2013-05-22       Impact factor: 5.948

3.  Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation.

Authors:  Antony Croxatto; Klaas Dijkstra; Guy Prod'hom; Gilbert Greub
Journal:  J Clin Microbiol       Date:  2015-05-13       Impact factor: 5.948

4.  Evaluation of the PREVI® Isola automated seeder system compared to reference manual inoculation for antibiotic susceptibility testing by the disk diffusion method.

Authors:  S Le Page; A van Belkum; C Fulchiron; R Huguet; D Raoult; J-M Rolain
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2015-06-20       Impact factor: 3.267

5.  Transrectal rigid-hybrid NOTES cholecystectomy can be performed without peritoneal contamination: a controlled porcine survival study.

Authors:  Philip C Müller; Jonas D Senft; Philip Gath; Daniel C Steinemann; Felix Nickel; Adrian T Billeter; Beat P Müller-Stich; Georg R Linke
Journal:  Surg Endosc       Date:  2017-08-10       Impact factor: 4.584

Review 6.  Automation in clinical microbiology.

Authors:  Paul P Bourbeau; Nathan A Ledeboer
Journal:  J Clin Microbiol       Date:  2013-03-20       Impact factor: 5.948

7.  Endolumenal colon occlusion reduces peritoneal contamination during a transrectal NOTES procedure: a controlled porcine survival study.

Authors:  Jonas D Senft; Benedict Carstensen; Alexander Mischnik; Rene Warschkow; Beat P Müller-Stich; Georg R Linke
Journal:  Surg Endosc       Date:  2015-10-20       Impact factor: 4.584

8.  The automated clinical microbiology laboratory: fact or fantasy?

Authors:  Nathan A Ledeboer; Steven D Dallas
Journal:  J Clin Microbiol       Date:  2014-03-19       Impact factor: 5.948

Review 9.  Emerging technologies for the clinical microbiology laboratory.

Authors:  Blake W Buchan; Nathan A Ledeboer
Journal:  Clin Microbiol Rev       Date:  2014-10       Impact factor: 26.132

10.  Automated versus manual sample inoculations in routine clinical microbiology: a performance evaluation of the fully automated InoqulA instrument.

Authors:  P Froment; H Marchandin; P Vande Perre; B Lamy
Journal:  J Clin Microbiol       Date:  2013-12-18       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.