Literature DB >> 25972424

Comparison of Inoculation with the InoqulA and WASP Automated Systems with Manual Inoculation.

Antony Croxatto1, Klaas Dijkstra2, Guy Prod'hom1, Gilbert Greub3.   

Abstract

The quality of sample inoculation is critical for achieving an optimal yield of discrete colonies in both monomicrobial and polymicrobial samples to perform identification and antibiotic susceptibility testing. Consequently, we compared the performance between the InoqulA (BD Kiestra), the WASP (Copan), and manual inoculation methods. Defined mono- and polymicrobial samples of 4 bacterial species and cloudy urine specimens were inoculated on chromogenic agar by the InoqulA, the WASP, and manual methods. Images taken with ImagA (BD Kiestra) were analyzed with the VisionLab version 3.43 image analysis software to assess the quality of growth and to prevent subjective interpretation of the data. A 3- to 10-fold higher yield of discrete colonies was observed following automated inoculation with both the InoqulA and WASP systems than that with manual inoculation. The difference in performance between automated and manual inoculation was mainly observed at concentrations of >10(6) bacteria/ml. Inoculation with the InoqulA system allowed us to obtain significantly more discrete colonies than the WASP system at concentrations of >10(7) bacteria/ml. However, the level of difference observed was bacterial species dependent. Discrete colonies of bacteria present in 100- to 1,000-fold lower concentrations than the most concentrated populations in defined polymicrobial samples were not reproducibly recovered, even with the automated systems. The analysis of cloudy urine specimens showed that InoqulA inoculation provided a statistically significantly higher number of discrete colonies than that with WASP and manual inoculation. Consequently, the automated InoqulA inoculation greatly decreased the requirement for bacterial subculture and thus resulted in a significant reduction in the time to results, laboratory workload, and laboratory costs.
Copyright © 2015, American Society for Microbiology. All Rights Reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25972424      PMCID: PMC4473203          DOI: 10.1128/JCM.03076-14

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  8 in total

1.  Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates.

Authors:  J H Glasson; L H Guthrie; D J Nielsen; F A Bethell
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

2.  First evaluation of the WASP, a new automated microbiology plating instrument.

Authors:  Paul P Bourbeau; Brandi Lynn Swartz
Journal:  J Clin Microbiol       Date:  2009-01-21       Impact factor: 5.948

3.  Development of the EUCAST disk diffusion antimicrobial susceptibility testing method and its implementation in routine microbiology laboratories.

Authors:  E Matuschek; D F J Brown; G Kahlmeter
Journal:  Clin Microbiol Infect       Date:  2013-10-17       Impact factor: 8.067

4.  Comparison of automated processing of flocked swabs with manual processing of fiber swabs for detection of nasal carriage of Staphylococcus aureus.

Authors:  Gillian Jones; Roger Matthews; Richard Cunningham; Peter Jenks
Journal:  J Clin Microbiol       Date:  2011-04-27       Impact factor: 5.948

Review 5.  International clinical practice guidelines for the treatment of acute uncomplicated cystitis and pyelonephritis in women: A 2010 update by the Infectious Diseases Society of America and the European Society for Microbiology and Infectious Diseases.

Authors:  Kalpana Gupta; Thomas M Hooton; Kurt G Naber; Björn Wullt; Richard Colgan; Loren G Miller; Gregory J Moran; Lindsay E Nicolle; Raul Raz; Anthony J Schaeffer; David E Soper
Journal:  Clin Infect Dis       Date:  2011-03-01       Impact factor: 9.079

6.  Automated versus manual sample inoculations in routine clinical microbiology: a performance evaluation of the fully automated InoqulA instrument.

Authors:  P Froment; H Marchandin; P Vande Perre; B Lamy
Journal:  J Clin Microbiol       Date:  2013-12-18       Impact factor: 5.948

7.  First evaluation of automated specimen inoculation for wound swab samples by use of the Previ Isola system compared to manual inoculation in a routine laboratory: finding a cost-effective and accurate approach.

Authors:  Alexander Mischnik; Markus Mieth; Cornelius J Busch; Stefan Hofer; Stefan Zimmermann
Journal:  J Clin Microbiol       Date:  2012-06-12       Impact factor: 5.948

Review 8.  Automation in clinical bacteriology: what system to choose?

Authors:  G Greub; G Prod'hom
Journal:  Clin Microbiol Infect       Date:  2011-05       Impact factor: 8.067

  8 in total
  15 in total

1.  Manual versus automated streaking system in clinical microbiology laboratory: Performance evaluation of Previ Isola for blood culture and body fluid samples.

Authors:  Qute Choi; Hyun Jin Kim; Jong Wan Kim; Gye Cheol Kwon; Sun Hoe Koo
Journal:  J Clin Lab Anal       Date:  2018-01-04       Impact factor: 2.352

Review 2.  A Decade of Development of Chromogenic Culture Media for Clinical Microbiology in an Era of Molecular Diagnostics.

Authors:  John D Perry
Journal:  Clin Microbiol Rev       Date:  2017-04       Impact factor: 26.132

3.  Impact of total laboratory automation on workflow and specimen processing time for culture of urine specimens.

Authors:  Melanie L Yarbrough; William Lainhart; Allison R McMullen; Neil W Anderson; Carey-Ann D Burnham
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2018-09-29       Impact factor: 3.267

4.  Automated direct screening for resistance of Gram-negative blood cultures using the BD Kiestra WorkCell.

Authors:  C S Heather; M Maley
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-10-02       Impact factor: 3.267

5.  Evaluation of the WASPLab Segregation Software To Automatically Analyze Urine Cultures Using Routine Blood and MacConkey Agars.

Authors:  Matthew L Faron; Blake W Buchan; Ryan F Relich; James Clark; Nathan A Ledeboer
Journal:  J Clin Microbiol       Date:  2020-03-25       Impact factor: 5.948

Review 6.  Consolidation of Clinical Microbiology Laboratories and Introduction of Transformative Technologies.

Authors:  Zisis Kozlakidis; Alex van Belkum; Olivier Vandenberg; Géraldine Durand; Marie Hallin; Andreas Diefenbach; Vanya Gant; Patrick Murray
Journal:  Clin Microbiol Rev       Date:  2020-02-26       Impact factor: 26.132

7.  Efficient processing of MRSA screening specimens by a modified inoculation protocol.

Authors:  Philipp Thelen; Kirsten Hornberg; Axel Hamprecht
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2018-07-06       Impact factor: 3.267

8.  Performance of Copan WASP for Routine Urine Microbiology.

Authors:  Chantal Quiblier; Marion Jetter; Mark Rominski; Forouhar Mouttet; Erik C Böttger; Peter M Keller; Michael Hombach
Journal:  J Clin Microbiol       Date:  2015-12-16       Impact factor: 5.948

9.  Towards automated detection, semi-quantification and identification of microbial growth in clinical bacteriology: A proof of concept.

Authors:  Antony Croxatto; Raphaël Marcelpoil; Cédrick Orny; Didier Morel; Guy Prod'hom; Gilbert Greub
Journal:  Biomed J       Date:  2017-12-26       Impact factor: 4.910

10.  Total Laboratory Automation and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Improve Turnaround Times in the Clinical Microbiology Laboratory: a Retrospective Analysis.

Authors:  Talent Theparee; Sanchita Das; Richard B Thomson
Journal:  J Clin Microbiol       Date:  2017-12-26       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.