Literature DB >> 6350352

Accuracy of calibrated-loop transfer.

A C Albers, R D Fletcher.   

Abstract

The accuracy of the 0.001-ml calibrated platinum loop was tested by two methods: visible absorption spectroscopy and weight determinations. By both methods it was demonstrated that the volume of the loop delivery is related to the angle at which the loop is withdrawn from the solution being sampled and the diameter of the container, provided that the volume in the container is adequate to cover the loop. Vertical sampling from small-diameter containers (less than or equal to 7-mm inside diameter) delivered approximately 50% of 0.001 ml, and sampling at a 45 degree angle from larger containers (greater than or equal to 22-mm inside diameter) gave a delivery volume of greater than 150% of 0.001 ml, resulting in a threefold difference in the amount delivered and an error rate of +/- 50%.

Entities:  

Mesh:

Year:  1983        PMID: 6350352      PMCID: PMC270741          DOI: 10.1128/jcm.18.1.40-42.1983

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  5 in total

1.  Culture of the urine.

Authors:  P D HOEPRICH
Journal:  J Lab Clin Med       Date:  1960-12

2.  Simplified quantitative methods for bacteriuria and pyuria.

Authors:  J McGeachie; A C Kennedy
Journal:  J Clin Pathol       Date:  1963-01       Impact factor: 3.411

3.  Bacterial counts in urine. 1. The reliability of the loop technique.

Authors:  J Haugen; O Strom; B Ostervold
Journal:  Acta Pathol Microbiol Scand       Date:  1968

4.  Simple method for quantitation of viable mycoplasmas.

Authors:  A C Albers; R D Fletcher
Journal:  Appl Environ Microbiol       Date:  1982-04       Impact factor: 4.792

5.  Aerobic and anaerobic urethral flora of healthy females in various physiological age groups and of females with urinary tract infections.

Authors:  T J Marrie; C A Swantee; M Hartlen
Journal:  J Clin Microbiol       Date:  1980-06       Impact factor: 5.948

  5 in total
  12 in total

1.  Accuracy and precision of quantitative calibrated loops in transfer of bronchoalveolar lavage fluid.

Authors:  J A Jacobs; E I De Brauwer; E I Cornelissen; M Drent
Journal:  J Clin Microbiol       Date:  2000-06       Impact factor: 5.948

Review 2.  Determination of fungicidal activities against yeasts and molds: lessons learned from bactericidal testing and the need for standardization.

Authors:  M A Pfaller; D J Sheehan; J H Rex
Journal:  Clin Microbiol Rev       Date:  2004-04       Impact factor: 26.132

3.  Rapid bioluminescence method for bacteriuria screening.

Authors:  M T Pezzlo; V Ige; A P Woolard; E M Peterson; L M de la Maza
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

4.  Evaluation of an Automated Instrument for Inoculating and Spreading Samples onto Agar Plates.

Authors:  J H Glasson; L H Guthrie; D J Nielsen; F A Bethell
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

5.  First evaluation of the WASP, a new automated microbiology plating instrument.

Authors:  Paul P Bourbeau; Brandi Lynn Swartz
Journal:  J Clin Microbiol       Date:  2009-01-21       Impact factor: 5.948

6.  Impact of introduction of the BD Kiestra InoqulA on urine culture results in a hospital clinical microbiology laboratory.

Authors:  Sharon Strauss; Paul P Bourbeau
Journal:  J Clin Microbiol       Date:  2015-03-04       Impact factor: 5.948

7.  Visual and clinical analysis of Bac-T-Screen urine screen results.

Authors:  E J Baron; M B Tyburski; R Almon; M Berman
Journal:  J Clin Microbiol       Date:  1988-11       Impact factor: 5.948

Review 8.  Standardization of the serum bactericidal test and its relationship to levels of antimicrobial agents.

Authors:  C W Stratton
Journal:  Eur J Clin Microbiol       Date:  1986-02       Impact factor: 3.267

9.  Simple method for quantifying viable bacterial numbers in sputum.

Authors:  A Pye; R A Stockley; S L Hill
Journal:  J Clin Pathol       Date:  1995-08       Impact factor: 3.411

Review 10.  Bronchoscopic diagnosis of pneumonia.

Authors:  V S Baselski; R G Wunderink
Journal:  Clin Microbiol Rev       Date:  1994-10       Impact factor: 26.132

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.