Pulse elongation and deconvolution filtering for medical ultrasonic imaging.

B Haider1, P A Lewin, K E Thomenius.   

Abstract

Range sidelobe artifacts which are associated with pulse compression methods can be reduced with a new method composed of pulse elongation and deconvolution (PED). While pulse compression and PED yield similar signal-to-noise ratio (SNR) improvements, PED inherently minimizes the range sidelobe artifacts. The deconvolution is implemented as a stabilized inverse filter. With proper selection of the excitation waveform an exact inverse filter can be implemented. The excitation waveform is optimized in a minimum mean square error (MMSE) sense. An analytical expression for the power spectrum of the optimal pulse is presented and several techniques to numerically optimize the excitation pulse are shown. The effects of PED are demonstrated in computer simulations as well as ultrasonic images.

Year:  1998        PMID: 18244162     DOI: 10.1109/58.646915

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  12 in total

1.  Detection performance theory for ultrasound imaging systems.

Authors:  Roger J Zemp; Mark D Parry; Craig K Abbey; Michael F Insana
Journal:  IEEE Trans Med Imaging       Date:  2005-03       Impact factor: 10.048

2.  Coded pulse excitation for ultrasonic strain imaging.

Authors:  Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-02       Impact factor: 2.725

3.  Modeling and phantom studies of ultrasonic wall shear rate measurements using coded pulse excitation.

Authors:  Jean K Tsou; Jie Liu; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-04       Impact factor: 2.725

4.  Imaging with unfocused regions of focused ultrasound beams.

Authors:  Roger Zemp; Michael F Insana
Journal:  J Acoust Soc Am       Date:  2007-03       Impact factor: 1.840

5.  Barker-coded excitation in ophthalmological ultrasound imaging.

Authors:  Sheng Zhou; Xiao-Chun Wang; Jun Yang; Jian-Jun Ji; Yan-Qun Wang
Journal:  Int J Clin Exp Med       Date:  2014-09-15

6.  Enhanced axial and lateral resolution using stabilized pulses.

Authors:  Shujie Chen; Kevin J Parker
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-08

7.  Amplitude modulated chirp excitation to reduce grating lobes and maintain ultrasound intensity at the focus of an array.

Authors:  Chandra P Karunakaran; Michael L Oelze
Journal:  Ultrasonics       Date:  2013-04-16       Impact factor: 2.890

8.  Combined chirp coded tissue harmonic and fundamental ultrasound imaging for intravascular ultrasound: 20-60 MHz phantom and ex vivo results.

Authors:  Jinhyoung Park; Xiang Li; Qifa Zhou; K Kirk Shung
Journal:  Ultrasonics       Date:  2012-07-21       Impact factor: 2.890

9.  Coded excitation plane wave imaging for shear wave motion detection.

Authors:  Pengfei Song; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-07       Impact factor: 2.725

10.  A post-beamforming 2-D pseudoinverse filter for coarsely sampled ultrasound arrays.

Authors:  Yayun Wan; Emad S Ebbini
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-09       Impact factor: 2.725

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.