Literature DB >> 21276653

Photoacoustic imaging with a commercial ultrasound system and a custom probe.

Xueding Wang1, J Brian Fowlkes, Jonathan M Cannata, Changhong Hu, Paul L Carson.   

Abstract

Building photoacoustic imaging (PAI) systems by using stand-alone ultrasound (US) units makes it convenient to take advantage of the state-of-the-art ultrasonic technologies. However, the sometimes limited receiving sensitivity and the comparatively narrow bandwidth of commercial US probes may not be sufficient to acquire high quality photoacoustic images. In this work, a high-speed PAI system has been developed using a commercial US unit and a custom built 128-element piezoelectric-polymer array (PPA) probe using a P(VDF-TrFE) film and flexible circuit to define the elements. Since the US unit supports simultaneous signal acquisition from 64 parallel receive channels, PAI data for synthetic image formation from a 64- or 128-element array aperture can be acquired after a single or dual laser firing, respectively. Therefore, two-dimensional (2-D) B-scan imaging can be achieved with a maximum frame rate up to 10 Hz, limited only by the laser repetition rate. The uniquely properties of P(VDF-TrFE) facilitated a wide -6 dB receiving bandwidth of over 120% for the array. A specially designed 128-channel preamplifier board made the connection between the array and the system cable, which not only enabled element electrical impedance matching but also further elevated the signal-to-noise ratio (SNR) to further enhance the detection of weak photoacoustic signals. Through the experiments on phantoms and rabbit ears, the good performance of this PAI system was demonstrated.
Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21276653      PMCID: PMC3040410          DOI: 10.1016/j.ultrasmedbio.2010.12.005

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  23 in total

1.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging?

Authors:  Omer Oralkan; A Sanli Ergun; Jeremy A Johnson; Mustafa Karaman; Utkan Demirci; Kambiz Kaviani; Thomas H Lee; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2002-11       Impact factor: 2.725

2.  Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction.

Authors:  Minghua Xu; Lihong V Wang
Journal:  Phys Rev E Stat Nonlin Soft Matter Phys       Date:  2003-05-09

3.  Quantitative two-dimensional photoacoustic tomography of osteoarthritis in the finger joints.

Authors:  Jiaying Xiao; Lei Yao; Yao Sun; Eric S Sobel; Jishan He; Huabei Jiang
Journal:  Opt Express       Date:  2010-07-05       Impact factor: 3.894

4.  Noninvasive photoacoustic tomography of human peripheral joints toward diagnosis of inflammatory arthritis.

Authors:  Xueding Wang; David L Chamberland; David A Jamadar
Journal:  Opt Lett       Date:  2007-10-15       Impact factor: 3.776

5.  Design considerations for piezoelectric polymer ultrasound transducers.

Authors:  L F Brown
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2000       Impact factor: 2.725

6.  Real-time in vivo photoacoustic and ultrasound imaging.

Authors:  Roy G M Kolkman; Peter J Brands; Wiendelt Steenbergen; Ton G van Leeuwen
Journal:  J Biomed Opt       Date:  2008 Sep-Oct       Impact factor: 3.170

7.  Laser optoacoustic imaging system for detection of breast cancer.

Authors:  Sergey A Ermilov; Tuenchit Khamapirad; Andre Conjusteau; Morton H Leonard; Ron Lacewell; Ketan Mehta; Tom Miller; Alexander A Oraevsky
Journal:  J Biomed Opt       Date:  2009 Mar-Apr       Impact factor: 3.170

8.  Three-dimensional photoacoustic imaging using a two-dimensional CMUT array.

Authors:  Srikant Vaithilingam; Te-Jen Ma; Yukio Furukawa; Ira O Wygant; Xuefeng Zhuang; Adam De La Zerda; Omer Oralkan; Aya Kamaya; Sanjiv S Gambhir; R Brooke Jeffrey; Butrus T Khuri-Yakub
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-11       Impact factor: 2.725

9.  Thermoacoustic molecular imaging of small animals.

Authors:  Robert A Kruger; William L Kiser; Daniel R Reinecke; Gabe A Kruger; Kathy D Miller
Journal:  Mol Imaging       Date:  2003-04       Impact factor: 4.488

10.  Design and fabrication of PIN-PMN-PT single-crystal high-frequency ultrasound transducers.

Authors:  Ping Sun; Qifa Zhou; Benpeng Zhu; Dawei Wu; Changhong Hu; Jonathan M Cannata; Jin Tian; Pengdi Han; Gaofeng Wang; K Kirk Shung
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-12       Impact factor: 2.725

View more
  16 in total

1.  Performance characterization of low-cost, high-speed, portable pulsed laser diode photoacoustic tomography (PLD-PAT) system.

Authors:  Paul Kumar Upputuri; Manojit Pramanik
Journal:  Biomed Opt Express       Date:  2015-09-24       Impact factor: 3.732

2.  Real-time photoacoustic and ultrasound dual-modality imaging system facilitated with graphics processing unit and code parallel optimization.

Authors:  Jie Yuan; Guan Xu; Yao Yu; Yu Zhou; Paul L Carson; Xueding Wang; Xiaojun Liu
Journal:  J Biomed Opt       Date:  2013-08       Impact factor: 3.170

3.  Photoacoustic and ultrasound dual-modality imaging of human peripheral joints.

Authors:  Guan Xu; Justin R Rajian; Gandikota Girish; Mariana J Kaplan; J Brian Fowlkes; Paul L Carson; Xueding Wang
Journal:  J Biomed Opt       Date:  2013-01       Impact factor: 3.170

4.  Simultaneous photoacoustic and optically mediated ultrasound microscopy: an in vivo study.

Authors:  Pavel Subochev; Anna Orlova; Marina Shirmanova; Anna Postnikova; Ilya Turchin
Journal:  Biomed Opt Express       Date:  2015-01-29       Impact factor: 3.732

5.  Spatial Angular Compounding of Photoacoustic Images.

Authors:  Hyun Jae Kang; Muyinatu A Lediju Bell; Xiaoyu Guo; Emad M Boctor
Journal:  IEEE Trans Med Imaging       Date:  2016-02-18       Impact factor: 10.048

6.  Elevational Synthetic Aperture Focusing for Three-Dimensional Photoacoustic Imaging Using a Clinical One-Dimensional Array Transducer.

Authors:  Changhan Yoon; Jeeun Kang; Tai-Kyong Song; Jin Ho Chang
Journal:  IEEE Trans Biomed Eng       Date:  2022-08-19       Impact factor: 4.756

Review 7.  Small-animal whole-body photoacoustic tomography: a review.

Authors:  Jun Xia; Lihong V Wang
Journal:  IEEE Trans Biomed Eng       Date:  2013-09-25       Impact factor: 4.538

8.  Photoacoustic tomography to identify inflammatory arthritis.

Authors:  Justin Rajesh Rajian; Gandikota Girish; Xueding Wang
Journal:  J Biomed Opt       Date:  2012-09       Impact factor: 3.170

9.  Ex vivo estimation of photoacoustic imaging for detecting thyroid microcalcifications.

Authors:  Jeeun Kang; Woong Youn Chung; Sang-Wook Kang; Hyeong Ju Kwon; Jaeheung Yoo; Eun-Kyung Kim; Jin Ho Chang; Tai-Kyong Song; Sohee Lee; Jin Young Kwak
Journal:  PLoS One       Date:  2014-11-21       Impact factor: 3.240

10.  Characterization and treatment monitoring of inflammatory arthritis by photoacoustic imaging: a study on adjuvant-induced arthritis rat model.

Authors:  Justin R Rajian; Xia Shao; David L Chamberland; Xueding Wang
Journal:  Biomed Opt Express       Date:  2013-05-17       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.