Internal knee derangement assessed with 3-minute three-dimensional isovoxel true FISP MR sequence: preliminary study.

Sylvain R Duc1, Christian W A Pfirrmann, Peter P Koch, Marco Zanetti, Juerg Hodler.   

Abstract

PURPOSE: To prospectively evaluate the accuracy of magnetic resonance (MR) imaging of the knee performed by using a three-dimensional (3D) isovoxel sequence involving an acquisition time of approximately 3 minutes, with surgery as the reference standard.
MATERIALS AND METHODS: The study was institutional review board approved. Written informed consent was obtained from all patients. Thirty knees of 29 patients (14 women, 15 men; mean age, 41 years) were prospectively examined by using a 3D isovoxel true fast imaging with steady-state precession (FISP) sequence with water excitation and secondary multiplanar reformations. All patients underwent arthroscopy within 12 days after true FISP MR imaging. Two blinded readers evaluated the MR images. Accuracy for detection of cartilage defects and anterior cruciate ligament (ACL) and meniscal tears, interobserver agreement, and intermethod agreement were calculated.
RESULTS: Overall sensitivity, specificity, and accuracy of isovoxel true FISP imaging for the diagnosis of cartilage defects were 45%, 83%, and 76%, respectively, for reader 1 and 63%, 82%, and 83%, respectively, for reader 2. Averaged (for readers 1 and 2) sensitivity, specificity, and accuracy of isovoxel true FISP imaging were, respectively, 80%, 95%, and 90% for diagnosis of ACL tear; 100%, 82%, and 90% for diagnosis of medial meniscal tear; and 83%, 83%, and 83% for diagnosis of lateral meniscal tear. The standard MR sequences used at the authors' institution had overall sensitivities, specificities, and accuracies of 39%, 83%, and 71%, respectively, for reader 1 and 37%, 85%, and 76%, respectively, for reader 2. Averaged sensitivity, specificity, and accuracy of the standard MR sequences were, respectively, 70%, 100%, and 90% for diagnosis of ACL tear; 96%, 77%, and 85% for diagnosis of medial meniscal tear; and 83%, 77%, and 78% for diagnosis of lateral meniscal tear.
CONCLUSION: The diagnostic performance of knee MR imaging performed by using a 3D water excitation isovoxel true FISP sequence and an imaging time of approximately 3 minutes is comparable to the diagnostic performance of the MR sequences used as standards at the authors' institution. (c) RSNA, 2008.

Entities:  

Mesh:

Year:  2008        PMID: 18227545     DOI: 10.1148/radiol.2462062092

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  28 in total

Review 1.  Magnetic resonance imaging of double-bundle anterior cruciate ligament reconstruction.

Authors:  Alexander Poellinger; Sven Scheffler; Bernd Hamm; Patrick Asbach
Journal:  Skeletal Radiol       Date:  2008-07-12       Impact factor: 2.199

2.  Isotropic 3D fast spin-echo imaging versus standard 2D imaging at 3.0 T of the knee--image quality and diagnostic performance.

Authors:  Oliver Ristow; Lynne Steinbach; Gregory Sabo; Roland Krug; Markus Huber; Isabel Rauscher; Ben Ma; Thomas M Link
Journal:  Eur Radiol       Date:  2009-01-10       Impact factor: 5.315

3.  Use magnetic resonance imaging to assess articular cartilage.

Authors:  Yuanyuan Wang; Anita E Wluka; Graeme Jones; Changhai Ding; Flavia M Cicuttini
Journal:  Ther Adv Musculoskelet Dis       Date:  2012-04       Impact factor: 5.346

Review 4.  Routine 3D magnetic resonance imaging of joints.

Authors:  Richard Kijowski; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2011-04       Impact factor: 4.813

5.  Combined 5-minute double-echo in steady-state with separated echoes and 2-minute proton-density-weighted 2D FSE sequence for comprehensive whole-joint knee MRI assessment.

Authors:  Akshay S Chaudhari; Kathryn J Stevens; Bragi Sveinsson; Jeff P Wood; Christopher F Beaulieu; Edwin H G Oei; Jarrett K Rosenberg; Feliks Kogan; Marcus T Alley; Garry E Gold; Brian A Hargreaves
Journal:  J Magn Reson Imaging       Date:  2018-12-23       Impact factor: 4.813

6.  Characterization of the collagen component of cartilage repair tissue of the talus with quantitative MRI: comparison of T2 relaxation time measurements with a diffusion-weighted double-echo steady-state sequence (dwDESS).

Authors:  M Kretzschmar; O Bieri; M Miska; M Wiewiorski; N Hainc; V Valderrabano; U Studler
Journal:  Eur Radiol       Date:  2014-11-19       Impact factor: 5.315

7.  Cartilage morphology at 3.0T: assessment of three-dimensional magnetic resonance imaging techniques.

Authors:  Christina A Chen; Richard Kijowski; Lauren M Shapiro; Michael J Tuite; Kirkland W Davis; Jessica L Klaers; Walter F Block; Scott B Reeder; Garry E Gold
Journal:  J Magn Reson Imaging       Date:  2010-07       Impact factor: 4.813

8.  3T MRI of the knee with optimised isotropic 3D sequences: Accurate delineation of intra-articular pathology without prolonged acquisition times.

Authors:  Osamah M Abdulaal; Louise Rainford; Peter MacMahon; Eoin Kavanagh; Marie Galligan; James Cashman; Allison McGee
Journal:  Eur Radiol       Date:  2017-04-21       Impact factor: 5.315

9.  Initial results of in vivo high-resolution morphological and biochemical cartilage imaging of patients after matrix-associated autologous chondrocyte transplantation (MACT) of the ankle.

Authors:  Sebastian Quirbach; Siegfried Trattnig; Stefan Marlovits; Valentin Zimmermann; Stephan Domayer; Ronald Dorotka; Tallal C Mamisch; Klaus Bohndorf; Goetz H Welsch
Journal:  Skeletal Radiol       Date:  2009-03-19       Impact factor: 2.199

Review 10.  Recent advances in MRI of articular cartilage.

Authors:  Garry E Gold; Christina A Chen; Seungbum Koo; Brian A Hargreaves; Neal K Bangerter
Journal:  AJR Am J Roentgenol       Date:  2009-09       Impact factor: 3.959