Literature DB >> 21448939

Routine 3D magnetic resonance imaging of joints.

Richard Kijowski1, Garry E Gold.   

Abstract

Due to its high spatial resolution and excellent tissue contrast, magnetic resonance imaging (MRI) has become the most commonly used imaging method to evaluate joints. Most musculoskeletal MRI is performed using 2D fast spin-echo sequences. However, 3D sequences have also been used for joint imaging and have the advantage of acquiring thin continuous slices through joints, which reduces the effects of partial volume averaging. With recent advances in MR technology, 3D sequences with isotropic resolution have been developed. These sequences allow high-quality multiplanar reformat images to be obtained following a single acquisition, thereby eliminating the need to repeat sequences with identical tissue contrast in different planes. Preliminary results on the diagnostic performance of 3D isotropic resolution sequences are encouraging. However, additional studies are needed to determine whether these sequences can replace currently used 2D fast spin-echo sequences for providing comprehensive joint assessment in clinical practice.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21448939      PMCID: PMC3069719          DOI: 10.1002/jmri.22342

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  96 in total

1.  Rapid musculoskeletal MRI with phase-sensitive steady-state free precession: comparison with routine knee MRI.

Authors:  Shreyas S Vasanawala; Brian A Hargreaves; John M Pauly; Dwight G Nishimura; Christopher F Beaulieu; Garry E Gold
Journal:  AJR Am J Roentgenol       Date:  2005-05       Impact factor: 3.959

2.  Can isotropic fast gradient echo imaging be substituted for conventional T1 weighted sequences in shoulder MR arthrography at 3 Tesla?

Authors:  Thomas Magee
Journal:  J Magn Reson Imaging       Date:  2007-07       Impact factor: 4.813

3.  Comparison of indirect isotropic MR arthrography and conventional MR arthrography of labral lesions and rotator cuff tears: a prospective study.

Authors:  Dae Kun Oh; Young Cheol Yoon; Jong Won Kwon; Sang-Hee Choi; Jee Young Jung; Sooho Bae; Jaechul Yoo
Journal:  AJR Am J Roentgenol       Date:  2009-02       Impact factor: 3.959

4.  Abnormalities of articular cartilage in the knee: analysis of available MR techniques.

Authors:  M P Recht; J Kramer; S Marcelis; M N Pathria; D Trudell; P Haghighi; D J Sartoris; D Resnick
Journal:  Radiology       Date:  1993-05       Impact factor: 11.105

5.  Magnetic resonance imaging of the hip: detection of labral and chondral abnormalities using noncontrast imaging.

Authors:  Douglas N Mintz; Timothy Hooper; David Connell; Robert Buly; Douglas E Padgett; Hollis G Potter
Journal:  Arthroscopy       Date:  2005-04       Impact factor: 4.772

6.  Diagnosis of articular cartilage abnormalities of the knee: prospective clinical evaluation of a 3D water-excitation true FISP sequence.

Authors:  Sylvain R Duc; Peter Koch; Marius R Schmid; Wilhelm Horger; Juerg Hodler; Christian W A Pfirrmann
Journal:  Radiology       Date:  2007-03-30       Impact factor: 11.105

7.  Adult hip dysplasia and osteoarthritis. Studies in radiology and clinical epidemiology.

Authors:  Steffen Jacobsen
Journal:  Acta Orthop Suppl       Date:  2006-12

8.  Collateral ligaments of the elbow: conventional MR imaging and MR arthrography with coronal oblique plane and elbow flexion.

Authors:  A Cotten; J Jacobson; J Brossmann; R Pedowitz; P Haghighi; D Trudell; D Resnick
Journal:  Radiology       Date:  1997-09       Impact factor: 11.105

9.  MR imaging of cartilage in cadaveric wrists: comparison between imaging at 1.5 and 3.0 T and gross pathologic inspection.

Authors:  Nadja Saupe; Christian W A Pfirrmann; Marius R Schmid; Thomas Schertler; Mirjana Manestar; Dominik Weishaupt
Journal:  Radiology       Date:  2007-02-20       Impact factor: 11.105

10.  MRI of hip osteoarthritis and implications for surgery.

Authors:  Tallal C Mamisch; Christoph Zilkens; Klaus A Siebenrock; Bernd Bittersohl; Young-Jo Kim; Stefan Werlen
Journal:  Magn Reson Imaging Clin N Am       Date:  2010-02       Impact factor: 2.266

View more
  27 in total

1.  Routine clinical knee MR reports: comparison of diagnostic performance at 1.5 T and 3.0 T for assessment of the articular cartilage.

Authors:  Jacob C Mandell; Jeffrey A Rhodes; Nehal Shah; Glenn C Gaviola; Andreas H Gomoll; Stacy E Smith
Journal:  Skeletal Radiol       Date:  2017-07-17       Impact factor: 2.199

2.  [Morphological and functional cartilage imaging].

Authors:  C Rehnitz; M-A Weber
Journal:  Orthopade       Date:  2015-04       Impact factor: 1.087

3.  MR arthrography of the shoulder: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Paolo Avanzi; William Mantovani; Flavia Dal Corso; Emanuele Demozzi; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-02-15       Impact factor: 3.469

4.  MR arthrography of the hip: evaluation of isotropic 3D intermediate-weighted FSE and hybrid GRE T1-weighted sequences.

Authors:  Giovanni Foti; Antonio Campacci; Michele Conati; Mirko Trentadue; Claudio Zorzi; Giovanni Carbognin
Journal:  Radiol Med       Date:  2017-06-09       Impact factor: 3.469

5.  Comparing an accelerated 3D fast spin-echo sequence (CS-SPACE) for knee 3-T magnetic resonance imaging with traditional 3D fast spin-echo (SPACE) and routine 2D sequences.

Authors:  Faysal F Altahawi; Kevin J Blount; Nicholas P Morley; Esther Raithel; Imran M Omar
Journal:  Skeletal Radiol       Date:  2016-10-15       Impact factor: 2.199

6.  Reliability of 3D localisation of ACL attachments on MRI: comparison using multi-planar 2D versus high-resolution 3D base sequences.

Authors:  Vimarsha Gopal Swami; June Cheng-Baron; Catherine Hui; Richard B Thompson; Jacob Lester Jaremko
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-03-21       Impact factor: 4.342

7.  [Morphological and functional cartilage imaging].

Authors:  C Rehnitz; M-A Weber
Journal:  Radiologe       Date:  2014-06       Impact factor: 0.635

8.  Accuracy of 3D dual echo steady state (DESS) MR arthrography to quantify acetabular cartilage thickness.

Authors:  Christine L Abraham; Neal K Bangerter; Lance S McGavin; Christopher L Peters; Alex J Drew; Christopher J Hanrahan; Andrew E Anderson
Journal:  J Magn Reson Imaging       Date:  2015-04-06       Impact factor: 4.813

9.  3D double-echo steady-state sequence assessment of hip joint cartilage and labrum at 3 Tesla: comparative analysis of magnetic resonance imaging and intraoperative data.

Authors:  Christoph Schleich; Tobias Hesper; Harish S Hosalkar; Fanni Rettegi; Christoph Zilkens; Rüdiger Krauspe; Gerald Antoch; Bernd Bittersohl
Journal:  Eur Radiol       Date:  2017-04-21       Impact factor: 5.315

10.  Patterns of cartilage degeneration in knees with medial tibiofemoral offset.

Authors:  Palanan Siriwanarangsun; Karen C Chen; Tim Finkenstaedt; Won C Bae; Sheronda Statum; Amilcare Gentili; Christine B Chung
Journal:  Skeletal Radiol       Date:  2018-10-24       Impact factor: 2.199

View more