Literature DB >> 1820313

Relationship between insertion torque and removal torque analyzed in fresh temporal bone.

M Ueda1, M Matsuki, M Jacobsson, A Tjellström.   

Abstract

Insertion torque and removal torque of fixtures were measured using human cadaver temporal bone and human living bone. The torque level for fracturing the threads of the bone was also measured. The maximum insertion torque exerted without causing a break in bone threads was 70.0 Ncm in bicortical bone and 50.0 Ncm in unicortical bone. The relationship between insertion torque and removal torque indicated a positive correlation between both sites. However, removal torque was lower than insertion torque in all measurements. The fracture points of bone threads were 77.0 Ncm in bicortical bone and 57.7 Ncm in unicortical bone by mean. Microfractures were observed mainly in the thread bases and were directed upward in the histologic specimens examined.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1820313

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  13 in total

1.  Relation between insertion torque and bone-implant contact percentage: an artificial bone study.

Authors:  Cheng Liu; Ming-Tzu Tsai; Heng-Li Huang; Michael Yuan-Chien Chen; Jui-Ting Hsu; Kuo-Chih Su; Chih-Han Chang; Aaron Yu-Jen Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

2.  Surface characteristics and mechanical behavior of retrieved orthodontic microimplants.

Authors:  Lu Lu; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018-05       Impact factor: 3.066

3.  Stability comparison between commercially available mini-implants and a novel design: part 1.

Authors:  Christine Hong; Haofu Lee; Richard Webster; Jinny Kwak; Benjamin M Wu; Won Moon
Journal:  Angle Orthod       Date:  2011-02-09       Impact factor: 2.079

4.  The effect of various thread designs on the initial stability of taper implants.

Authors:  Ju-Hee Park; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

5.  Effect of rotation bump on removal torque of orthodontic mini-implants.

Authors:  Odontuya Gansukh; Jong-Wha Jeong; Jong-Wan Kim; Young-Kyun Kim; Jong-Ho Lee; Tae-Woo Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-12-23

Review 6.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

7.  Influence of cortical bone and implant design in the primary stability of dental implants measured by two different devices of resonance frequency analysis: An in vitro study.

Authors:  David Chávarri-Prado; Aritza Brizuela-Velasco; Markel Diéguez-Pereira; Esteban Pérez-Pevida; Antonio Jiménez-Garrudo; Iratxe Viteri-Agustín; Alejandro Estrada-Martínez; Oier Montalbán-Vadillo
Journal:  J Clin Exp Dent       Date:  2020-03-01

8.  Stress distributions in peri-miniscrew areas from cylindrical and tapered miniscrews inserted at different angles.

Authors:  Sung-Hwan Choi; Seong-Jin Kim; Kee-Joon Lee; Sang-Jin Sung; Youn-Sic Chun; Chung-Ju Hwang
Journal:  Korean J Orthod       Date:  2016-07-25       Impact factor: 1.372

9.  Effect of implant design on primary stability using torque-time curves in artificial bone.

Authors:  Yoko Yamaguchi; Makoto Shiota; Motohiro Munakata; Shohei Kasugai; Masahiko Ozeki
Journal:  Int J Implant Dent       Date:  2015-08-08

10.  Evaluation of the effects of different surface configurations on stability of miniscrews.

Authors:  Tolga Topcuoglu; A Altuğ Bicakci; M Cihat Avunduk; Z Deniz Sahin Inan
Journal:  ScientificWorldJournal       Date:  2013-07-01
View more