| Literature DB >> 30534547 |
Lokesh Gudda Naik1, Won Yong Shon1, I C Clarke2, Jun-Gyu Moon3, Piyush Mukund1, Sang-Min Kim3.
Abstract
Pseudotumors are not uncommon complications after total hip arthroplasty (THA) and may occur due to differences in bearing surfaces of the head and the liner ranging from soft to hard articulation. The most common causes of pseudotumors are foreign-body reaction, hypersensitivity and wear debris. The spectrum of pseudotumor presentation following THA varies greatly-from completely asymptomatic to clear implant failure. We report a case of pseudo-tumor formation with acetabular cup aseptic loosening after revision ceramic-on-metal hip arthroplasty. The patient described herein underwent pseudotumor excision and re-revision complex arthroplasty using a trabecular metal shell and buttress with ceramic-on-polyethylene THA. Surgeons should be aware of the possibility of a pseudotumor when dealing with revisions to help prevent rapid progression of cup loosening and implant failure, and should intervene early to avoid complex arthroplasty procedures.Entities:
Keywords: Ceramic on metal; Ceramic on polyethylene; Pseudotumor; Total hip arthroplasty
Year: 2018 PMID: 30534547 PMCID: PMC6284071 DOI: 10.5371/hp.2018.30.4.276
Source DB: PubMed Journal: Hip Pelvis ISSN: 2287-3260
Fig. 1(A, B) Anteroposterior radiograph of left hip. (A) One year after revision cementless ceramic-on-metal hip arthroplasty with well-aligned and fixed implants. (B) One month after the initial presentation of mild discomfort, radiograph revealed acetabular cup superior and lateral migration with a well-fixed femoral stem. (C) Ultrasonography of left hip revealing a cystic lesion in the iliopsoas area (3.76×3.12×2.95 cm).
Fig. 2(A–C) Computed tomography scans of both hips revealing a space-occupying lesion in the iliopsoas region which is in communication with the left hip joint (arrow).
Fig. 3(A, B) Intraoperative photograph demonstrating ceramic head and metal liner with metal staining and metallosis of soft tissue. (C) Photograph demonstrating cup and metal liner with metal staining and metallosis of soft tissue.
Fig. 4(A, B) Removed components with defect measurements.
Fig. 5Postoperative anteroposterior radiograph after second-stage revision with trabecular metal cup and buttress with head and liner exchanged.
Fig. 6Histological sections (H&E stain). (A) Chronic inflammation indicated by the presence of black pigment and pseudotumor perivascular lymphocytes (×40). (B) Necrotic debris with fibrosis, fibrin material and lymphocytes (×100). (C) Photomicrograph demonstrating histiocyte infiltration with gray and black metal particles in the tissue surrounding the granuloma (×400). (D) High-power magnification demonstrating the presence of histiocytes and foreign body type giant cells containing black metallic particles (×400).