Rate of wear in total hip replacement.

J Charnley, D K Halley.   

Abstract

The wear of high molecular weight polyethylene sockets was measured on radiographs, over a period of 9 to 10 years, in a group of patients whose ages averaged 73.3 years at the end of the period. The average rate of wear was 0.15 mm/year and 68 per cent of patients followed this pattern. Wear more than 2.5 mm in 10 years occurred in 15 per cent. There was a diminution in the rate of wear with the passage of time; in the second 5 years the rate of wear was approximately 40 per cent less than in the first 5 years. Body weight and physical activity did not appear to have any relationship to the final amount of wear. In a second series of very disabled subjects under 30 years of age (33 patients, 59 hips, followed only for an average of 38.4 months) the wear was rather more than in the previous series. Most remarkable was the performance of 4 patients, below the age of 50, who were considered completely normal for their age (category A); three of these wore less than the average for the main series.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1192630

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  40 in total

1.  Wear degradation of long-term in vivo exposed alumina-on-alumina hip joints: linking nanometer-scale phenomena to macroscopic joint design.

Authors:  Yasuhito Takahashi; Nobuhiko Sugano; Wenliang Zhu; Takashi Nishii; Takashi Sakai; Masaki Takao; Giuseppe Pezzotti
Journal:  J Mater Sci Mater Med       Date:  2011-11-22       Impact factor: 3.896

Review 2.  Edge loading has a paradoxical effect on wear in metal-on-polyethylene total hip arthroplasties.

Authors:  William H Harris
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

Review 3.  [Musculoskeletal load analysis. A biomechanical explanation for clinical results--and more?].

Authors:  M O Heller; J H Schröder; G Matziolis; A Sharenkov; W R Taylor; C Perka; G N Duda
Journal:  Orthopade       Date:  2007-03       Impact factor: 1.087

4.  Long-term radiographic assessment of cemented polyethylene acetabular cups.

Authors:  Sophie Williams; Graham Isaac; Neil Porter; John Fisher; John Older
Journal:  Clin Orthop Relat Res       Date:  2008-01-10       Impact factor: 4.176

5.  Early polyethylene wear and excessive acetabular granuloma in an uncemented HA-coated total hip arthroplasty--midterm results of a prospective study.

Authors:  Jörg Axel Karl Ohnsorge; Jack Davis; Uwe Maus; Muharrem Saklak; Markus Weisskopf; Dieter Christian Wirtz
Journal:  HSS J       Date:  2006-09

6.  Early follow-up for a hybrid total hip arthroplasty using a metal-backed acetabular component designed to reduce "backside" polyethylene wear.

Authors:  Colin E Poole; Shantanu S Patil; Darryl D D'Lima; Clifford W Colwell
Journal:  HSS J       Date:  2005-09

7.  Total hip replacement with bone grafting using the removed femoral head in severe acetabular dysplasia.

Authors:  G Stringa; R P Pitto; G V Di Muria; M Marcucci
Journal:  Int Orthop       Date:  1995       Impact factor: 3.075

8.  [Impacted acetabular cups].

Authors:  A Dambreville; P Lautridou
Journal:  Eur J Orthop Surg Traumatol       Date:  2017-03-10

9.  Polyethylene in total hip arthroplasty: half a century in the limelight.

Authors:  Eduardo García-Rey; Eduardo García-Cimbrelo
Journal:  J Orthop Traumatol       Date:  2010-05-27

10.  No differences in outcomes between cemented and uncemented acetabular components after 12-14 years: results from a randomized controlled trial comparing Duraloc with Charnley cups.

Authors:  Kristian Bjørgul; Wendy M Novicoff; S T Andersen; K Brevig; F Thu; M Wiig; O Ahlund
Journal:  J Orthop Traumatol       Date:  2010-03-03
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.