Literature DB >> 18195249

Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography.

A Suomalainen1, T Vehmas, M Kortesniemi, S Robinson, J Peltola.   

Abstract

OBJECTIVES: The aim of this study was to evaluate the accuracy of linear measurements obtained with dental cone beam CT (CBCT) and multislice CT (MSCT) by altering radiation doses using pre-operative planning of the placement of oral implants as a model.
METHODS: A human cadaver mandible was examined in two edentulous areas and one dentate area using CBCT and MSCT. The mandible was examined both dry and immersed in sucrose solution isointense with soft tissue. Two readers measured four linear distances twice from each section. The mandible was cut into 4 mm thick slices at three marked places. These slices were microradiographed and used as the gold standard for measurements from each section.
RESULTS: The intraclass correlations between the intra- and interobserver readings obtained with the different methods showed almost perfect matches. The measurement error (ME) showed significant differences between the methods studied (P = 0.022): the mean ME was 4.7% for CBCT and 8.8% for MSCT of the dry mandible, 2.3% and 6.6%, respectively, for the mandible immersed in sucrose solution and 5.4% for low-dose MSCT. Lowering the MSCT radiation dose to less than a quarter of its conventional original value did not significantly affect the ME.
CONCLUSIONS: CBCT is a reliable tool for implant-planning measurements when compared with MSCT. In this study, a considerable radiation dose reduction could be achieved with low-dose MSCT examinations without a major loss of measurement accuracy.

Entities:  

Mesh:

Year:  2008        PMID: 18195249     DOI: 10.1259/dmfr/14140281

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  51 in total

1.  Effect of electric potential and current on mandibular linear measurements in cone beam CT.

Authors:  S Panmekiate; W Apinhasmit; A Petersson
Journal:  Dentomaxillofac Radiol       Date:  2012-04-12       Impact factor: 2.419

2.  A comparative study of accuracy of detection of surface osseous changes in the temporomandibular joint using multidetector CT and cone beam CT.

Authors:  E H Zain-Alabdeen; R I Alsadhan
Journal:  Dentomaxillofac Radiol       Date:  2012-03       Impact factor: 2.419

3.  Accuracy of CBCT measurements of a human skull.

Authors:  Kivanç Kamburoğlu; Eray Kolsuz; Hakan Kurt; Cenk Kiliç; Tuncer Özen; Candan Semra Paksoy
Journal:  J Digit Imaging       Date:  2011-10       Impact factor: 4.056

Review 4.  Modern dental imaging: a review of the current technology and clinical applications in dental practice.

Authors:  Bart Vandenberghe; Reinhilde Jacobs; Hilde Bosmans
Journal:  Eur Radiol       Date:  2010-06-11       Impact factor: 5.315

5.  High-resolution CT of transplanted teeth: imaging technique and measurement accuracy.

Authors:  André Gahleitner; Ulrike Kuchler; Peter Homolka; Janina Heschl; Georg Watzek; Herwig Imhof
Journal:  Eur Radiol       Date:  2008-08-09       Impact factor: 5.315

6.  Accuracy of linear intraoral measurements using cone beam CT and multidetector CT: a tale of two CTs.

Authors:  R Patcas; G Markic; L Müller; O Ullrich; T Peltomäki; C J Kellenberger; C A Karlo
Journal:  Dentomaxillofac Radiol       Date:  2012-05-03       Impact factor: 2.419

7.  Comparison of mesiodistal space measurements of single-implant sites on panoramic and oblique images generated by cone-beam CT.

Authors:  Mustafa Alkhader; Malik Hudieb
Journal:  Surg Radiol Anat       Date:  2013-08-27       Impact factor: 1.246

8.  Accuracy of chemically created periapical lesion measurements using limited cone beam computed tomography.

Authors:  K Kamburoğlu; C Kiliç; T Ozen; S Horasan
Journal:  Dentomaxillofac Radiol       Date:  2010-02       Impact factor: 2.419

Review 9.  Preoperative imaging procedures for lower wisdom teeth removal.

Authors:  Lennart Flygare; Anders Ohman
Journal:  Clin Oral Investig       Date:  2008-04-30       Impact factor: 3.573

10.  Assessing the need for computed tomography for lower-third-molar extraction: a survey among 322 dentists.

Authors:  S Sivolella; G Boccuzzo; E Gasparini; G De Conti; M Berengo
Journal:  Radiol Med       Date:  2011-04-19       Impact factor: 3.469

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.