Literature DB >> 18690456

High-resolution CT of transplanted teeth: imaging technique and measurement accuracy.

André Gahleitner1, Ulrike Kuchler, Peter Homolka, Janina Heschl, Georg Watzek, Herwig Imhof.   

Abstract

The aim of this study was to determine the accuracy of crown diameter measurements by dental CT as a tool for preoperative diagnosis before tooth transplantations. Fifty-eight patients underwent clinically indicated dental CT. The diameter of the crowns were measured by CT using a standard protocol (1.5-mm slice thickness, 1-mm table feed, 120 kV, 25-75 mA/s, 2-s scan time/slice, 512 matrix) and a standard dental software package. Postoperatively, the same distances were clinically measured using a sliding gauge. The degree of the deviation between CT measurements and clinical measurements was in the sub-millimeter range. According to the regression analysis, the correlation coefficient equals 0.98 and 0.97, indicating a strong relationship between the CT and the manual measurement of the crown diameter in the bucco-lingual and the mesio-distal direction. The mean deviation of CT measurements with regard to the bucco-lingual diameter of the crown was +0.08 mm (SD: +/-0.38 mm). For the mesio-distal diameter, the mean deviation of CT measurements was -0.24 mm (SD: +/-0.53 mm). These results demonstrate that dental CT promises to be a valuable tool for the evaluation of the potential and optimal size and site for tooth transplantations.

Entities:  

Mesh:

Year:  2008        PMID: 18690456     DOI: 10.1007/s00330-008-1075-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  17 in total

Review 1.  [Dental CT in the planning of surgical procedures. Its significance in the oro-maxillofacial region from the viewpoint of the dentist].

Authors:  P Solar; A Gahleitner
Journal:  Radiologe       Date:  1999-12       Impact factor: 0.635

2.  The accuracy of 4 panoramic units in the projection of mesiodistal tooth angulations.

Authors:  Ian W Mckee; Philip C Williamson; Ernest W Lam; Giseon Heo; Kenneth E Glover; Paul W Major
Journal:  Am J Orthod Dentofacial Orthop       Date:  2002-02       Impact factor: 2.650

3.  Accuracy of linear measurements using dental cone beam and conventional multislice computed tomography.

Authors:  A Suomalainen; T Vehmas; M Kortesniemi; S Robinson; J Peltola
Journal:  Dentomaxillofac Radiol       Date:  2008-01       Impact factor: 2.419

4.  [Low-dosage dental CT].

Authors:  P Rustemeyer; U Streubühr; H P Hohn; R Rustemeyer; H T Eich; V John-Mikolajewski; R D Müller
Journal:  Rofo       Date:  1999-08

5.  Computed tomography: Part II. Preoperative assessment of the maxilla for endosseous implant surgery.

Authors:  M S Schwarz; S L Rothman; M L Rhodes; N Chafetz
Journal:  Int J Oral Maxillofac Implants       Date:  1987       Impact factor: 2.804

6.  Radiology in the management of impacted teeth.

Authors:  I P Sewerin
Journal:  Int Dent J       Date:  1987-03       Impact factor: 2.512

7.  Measurements of distances related to the mandibular canal in radiographs.

Authors:  C Lindh; A Petersson; B Klinge
Journal:  Clin Oral Implants Res       Date:  1995-06       Impact factor: 5.977

8.  [3-dimensional computed tomographic imaging of the dentate alveolar ridge. A radiological-histological comparison].

Authors:  R Fuhrmann; H Wehrbein; P Diedrich
Journal:  Fortschr Kieferorthop       Date:  1993-04

9.  [Replantation and transplantation of teeth and tooth germs].

Authors:  A Eskici
Journal:  Dtsch Zahnarztl Z       Date:  1980-02

Review 10.  [Tooth transplantation].

Authors:  Björn Lang; Yango Pohl; Andreas Filippi
Journal:  Schweiz Monatsschr Zahnmed       Date:  2003
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.