Abstract

OBJECTIVE: To compare the clinical performance and the survival rate of two mini-implant systems with different surface characteristics under immediate orthodontic loading.
MATERIALS AND METHODS: Seventeen machined titanium (MT) mini-implants and 15 sandblasted, large grit, acid-etched (SLA) mini-implants were placed in 10 patients. The mini-implants were immediately loaded and the patients seen at 7, 14, 30, 60, and 150 days. Clinical parameters such as anatomical location, character of the soft tissue at the screw head emergence, type of mini-implant system, diameter, and length were analyzed. In addition, the insertion torque recorded at the time of insertion was also assessed. Survival rate and clinical parameters were evaluated by the chi-square exact tests using the SAS version 9.1.
RESULTS: The overall survival rate was 87.5%. Over the four failing mini-implants, three were MT and one SLA resulting in an individual survival rate of 82.4% and 93.4%, respectively. In the failure group, all the fixtures had their screw emergence at the oral mucosa and recorded a torque range of less than 15 Ncm. The insertion torque statistically influenced the survival rate of the mini-implants (P < .05). Surface treatment, anatomical location, as well as soft tissue emergence were not statistically significant.
CONCLUSION: Surface characteristics did not appear to influence survival rates of immediately loaded mini-implants.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18193961     DOI: 10.2319/100206-401.1

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  20 in total

1.  Surface characteristics and mechanical behavior of retrieved orthodontic microimplants.

Authors:  Lu Lu; Hyo-Sang Park
Journal:  J Zhejiang Univ Sci B       Date:  2018-05       Impact factor: 3.066

2.  Histomorphometric evaluation of the effects of various diode lasers and force levels on orthodontic mini screw stability.

Authors:  Merve Goymen; Eren Isman; Lale Taner; Mehmet Kurkcu
Journal:  Photomed Laser Surg       Date:  2015-01       Impact factor: 2.796

3.  Experimental investigation of the fracture torque of orthodontic anchorage screws.

Authors:  Susanne Reimann; Mustafa Ayubi; Fraser McDonald; Christoph Bourauel
Journal:  J Orofac Orthop       Date:  2016-04-20       Impact factor: 1.938

4.  Roughness and wettability effect on histological and mechanical response of self-drilling orthodontic mini-implants.

Authors:  Eduardo Espinar-Escalona; Luis-Alberto Bravo-Gonzalez; Marta Pegueroles; Francisco Javier Gil
Journal:  Clin Oral Investig       Date:  2016-03-09       Impact factor: 3.573

5.  Insertion torque values and success rates for paramedian insertion of orthodontic mini-implants : A retrospective study.

Authors:  Bruno Di Leonardo; Björn Ludwig; Jörg Alexander Lisson; Luca Contardo; Rossano Mura; Jan Hourfar
Journal:  J Orofac Orthop       Date:  2018-02-20       Impact factor: 1.938

6.  Stability changes of miniscrew implants over time.

Authors:  Derid S Ure; Donald R Oliver; Ki Beom Kim; Ana Cláudia Melo; Peter H Buschang
Journal:  Angle Orthod       Date:  2011-05-25       Impact factor: 2.079

7.  Effect of vertical placement angle on the insertion torque of mini-implants in human alveolar bone.

Authors:  Rafael Ribeiro Maya; Célia Regina Maio Pinzan-Vercelino; Julio de Araujo Gurgel
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

8.  Evaluation of cytotoxicity and corrosion resistance of orthodontic mini-implants.

Authors:  Celha Borges Costa Alves; Márcio Nunes Segurado; Miriam Cristina Leandro Dorta; Fátima Ribeiro Dias; Maurício Guilherme Lenza; Marcos Augusto Lenza
Journal:  Dental Press J Orthod       Date:  2016 Sep-Oct

9.  Cross-sectional evaluation of the prevalence and factors associated with soft tissue scarring after the removal of miniscrews.

Authors:  Sung-ah Jung; Yoon Jeong Choi; Dong-Won Lee; Kyung-Ho Kim; Chooryung J Chung
Journal:  Angle Orthod       Date:  2014-08-06       Impact factor: 2.079

Review 10.  Does cortical thickness influence the primary stability of miniscrews?: A systematic review and meta-analysis.

Authors:  Mariana Marquezan; Cláudia Trindade Mattos; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza; Lucianne Cople Maia
Journal:  Angle Orthod       Date:  2014-04-02       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.