Literature DB >> 18175857

Robust heart rate estimation from multiple asynchronous noisy sources using signal quality indices and a Kalman filter.

Q Li1, R G Mark, G D Clifford.   

Abstract

Physiological signals such as the electrocardiogram (ECG) and arterial blood pressure (ABP) in the intensive care unit (ICU) are often severely corrupted by noise, artifact and missing data, which lead to large errors in the estimation of the heart rate (HR) and ABP. A robust HR estimation method is described that compensates for these problems. The method is based upon the concept of fusing multiple signal quality indices (SQIs) and HR estimates derived from multiple electrocardiogram (ECG) leads and an invasive ABP waveform recorded from ICU patients. Physiological SQIs were obtained by analyzing the statistical characteristics of each waveform and their relationships to each other. HR estimates from the ECG and ABP are tracked with separate Kalman filters, using a modified update sequence based upon the individual SQIs. Data fusion of each HR estimate was then performed by weighting each estimate by the Kalman filters' SQI-modified innovations. This method was evaluated on over 6000 h of simultaneously acquired ECG and ABP from a 437 patient subset of ICU data by adding real ECG and realistic artificial ABP noise. The method provides an accurate HR estimate even in the presence of high levels of persistent noise and artifact, and during episodes of extreme bradycardia and tachycardia.

Entities:  

Mesh:

Year:  2007        PMID: 18175857      PMCID: PMC2259026          DOI: 10.1088/0967-3334/29/1/002

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  20 in total

1.  PhysioBank, PhysioToolkit, and PhysioNet: components of a new research resource for complex physiologic signals.

Authors:  A L Goldberger; L A Amaral; L Glass; J M Hausdorff; P C Ivanov; R G Mark; J E Mietus; G B Moody; C K Peng; H E Stanley
Journal:  Circulation       Date:  2000-06-13       Impact factor: 29.690

2.  The impact of the MIT-BIH arrhythmia database.

Authors:  G B Moody; R G Mark
Journal:  IEEE Eng Med Biol Mag       Date:  2001 May-Jun

3.  The principles of software QRS detection.

Authors:  Bert-Uwe Köhler; Carsten Hennig; Reinhold Orglmeister
Journal:  IEEE Eng Med Biol Mag       Date:  2002 Jan-Feb

4.  Building ICU artifact detection models with more data in less time.

Authors:  C L Tsien; I S Kohane; N McIntosh
Journal:  Proc AMIA Symp       Date:  2001

5.  Reduction of false arterial blood pressure alarms using signal quality assessment and relationships between the electrocardiogram and arterial blood pressure.

Authors:  W Zong; G B Moody; R G Mark
Journal:  Med Biol Eng Comput       Date:  2004-09       Impact factor: 2.602

6.  A comparison of the noise sensitivity of nine QRS detection algorithms.

Authors:  G M Friesen; T C Jannett; M A Jadallah; S L Yates; S R Quint; H T Nagle
Journal:  IEEE Trans Biomed Eng       Date:  1990-01       Impact factor: 4.538

7.  Quantitative investigation of QRS detection rules using the MIT/BIH arrhythmia database.

Authors:  P S Hamilton; W J Tompkins
Journal:  IEEE Trans Biomed Eng       Date:  1986-12       Impact factor: 4.538

8.  MIMIC II: a massive temporal ICU patient database to support research in intelligent patient monitoring.

Authors:  M Saeed; C Lieu; G Raber; R G Mark
Journal:  Comput Cardiol       Date:  2002

Review 9.  Alarms in the intensive care unit: how can the number of false alarms be reduced?

Authors:  M C Chambrin
Journal:  Crit Care       Date:  2001-05-23       Impact factor: 9.097

10.  Artificial arterial blood pressure artifact models and an evaluation of a robust blood pressure and heart rate estimator.

Authors:  Qiao Li; Roger G Mark; Gari D Clifford
Journal:  Biomed Eng Online       Date:  2009-07-08       Impact factor: 2.819

View more
  70 in total

1.  Sensor fusion methods for reducing false alarms in heart rate monitoring.

Authors:  Gabriel Borges; Valner Brusamarello
Journal:  J Clin Monit Comput       Date:  2015-10-06       Impact factor: 2.502

2.  Reliable real-time calculation of heart-rate complexity in critically ill patients using multiple noisy waveform sources.

Authors:  Nehemiah T Liu; Leopoldo C Cancio; Jose Salinas; Andriy I Batchinsky
Journal:  J Clin Monit Comput       Date:  2013-08-30       Impact factor: 2.502

3.  Model-based data integration in clinical environments.

Authors:  Thomas Heldt; George C Verghese
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2010

Review 4.  A review of signals used in sleep analysis.

Authors:  A Roebuck; V Monasterio; E Gederi; M Osipov; J Behar; A Malhotra; T Penzel; G D Clifford
Journal:  Physiol Meas       Date:  2013-12-17       Impact factor: 2.833

5.  A robust approach toward recognizing valid arterial-blood-pressure pulses.

Authors:  Shadnaz Asgari; Marvin Bergsneider; Xiao Hu
Journal:  IEEE Trans Inf Technol Biomed       Date:  2009-10-30

6.  An open source benchmarked toolbox for cardiovascular waveform and interval analysis.

Authors:  Adriana N Vest; Giulia Da Poian; Qiao Li; Chengyu Liu; Shamim Nemati; Amit J Shah; Gari D Clifford
Journal:  Physiol Meas       Date:  2018-10-11       Impact factor: 2.833

7.  An investigation of patterns in hemodynamic data indicative of impending hypotension in intensive care.

Authors:  Joon Lee; Roger G Mark
Journal:  Biomed Eng Online       Date:  2010-10-25       Impact factor: 2.819

8.  Assessing ECG signal quality indices to discriminate ECGs with artefacts from pathologically different arrhythmic ECGs.

Authors:  C Daluwatte; L Johannesen; L Galeotti; J Vicente; D G Strauss; C G Scully
Journal:  Physiol Meas       Date:  2016-07-25       Impact factor: 2.833

9.  False alarm reduction in critical care.

Authors:  Gari D Clifford; Ikaro Silva; Benjamin Moody; Qiao Li; Danesh Kella; Abdullah Chahin; Tristan Kooistra; Diane Perry; Roger G Mark
Journal:  Physiol Meas       Date:  2016-07-25       Impact factor: 2.833

10.  Robust parameter extraction for decision support using multimodal intensive care data.

Authors:  G D Clifford; W J Long; G B Moody; P Szolovits
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2009-01-28       Impact factor: 4.226

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.