Literature DB >> 2303275

A comparison of the noise sensitivity of nine QRS detection algorithms.

G M Friesen1, T C Jannett, M A Jadallah, S L Yates, S R Quint, H T Nagle.   

Abstract

The noise sensitivities for nine different QRS detection algorithms were measured for a normal, single-channel lead II, synthesized ECG corrupted with five different types of synthesized noise. The noise types were electromyographic interference, 60 Hz powerline interference, baseline drift due to respiration, abrupt baseline shift, and a composite noise constructed from all of the other noise types. The percentage of QRS complexes detected, the number of false positives, and the detection delay were measured. None of the algorithms were able to detect all QRS complexes without any false positives for all of the noise types at the highest noise level. Algorithms based on amplitude and slope had the highest performance for EMG-corrupted ECG. An algorithm using a digital filter had the best performance for the composite noise corrupted data.

Mesh:

Year:  1990        PMID: 2303275     DOI: 10.1109/10.43620

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  75 in total

1.  Ventricular beat classifier using fractal number clustering.

Authors:  H Bakardjian
Journal:  Med Biol Eng Comput       Date:  1992-09       Impact factor: 2.602

2.  Evaluation of the effects of mediastinal radiation therapy on autonomic nervous system.

Authors:  Ayse Hoca; Metin Yildiz; Gokhan Ozyigit
Journal:  Med Oncol       Date:  2012-04-24       Impact factor: 3.064

3.  Analysis of the mobile phone effect on the heart rate variability by using the largest Lyapunov exponent.

Authors:  Derya Yılmaz; Metin Yıldız
Journal:  J Med Syst       Date:  2009-06-18       Impact factor: 4.460

4.  Morphology variability analysis of wrist pulse waveform for assessment of arteriosclerosis status.

Authors:  Lisheng Xu; Max Q-H Meng; Xianghua Qi; Kuanquan Wang
Journal:  J Med Syst       Date:  2010-06       Impact factor: 4.460

5.  An adaptive real-time beat detection method for continuous pressure signals.

Authors:  Xiaochang Liu; Gaofeng Wang; Jia Liu
Journal:  J Clin Monit Comput       Date:  2015-09-11       Impact factor: 2.502

6.  Comparative study of ECG signal denoising by wavelet thresholding in empirical and variational mode decomposition domains.

Authors:  Salim Lahmiri
Journal:  Healthc Technol Lett       Date:  2014-09-16

7.  Robust detection of premature ventricular contractions using sparse signal decomposition and temporal features.

Authors:  M Sabarimalai Manikandan; Barathram Ramkumar; Pranav S Deshpande; Tilendra Choudhary
Journal:  Healthc Technol Lett       Date:  2015-11-19

8.  Reliable real-time calculation of heart-rate complexity in critically ill patients using multiple noisy waveform sources.

Authors:  Nehemiah T Liu; Leopoldo C Cancio; Jose Salinas; Andriy I Batchinsky
Journal:  J Clin Monit Comput       Date:  2013-08-30       Impact factor: 2.502

9.  ECG compression by modelling the instantaneous module/phase of its DCT.

Authors:  Jean-Claude Nunes; Amine Nait-Ali
Journal:  J Clin Monit Comput       Date:  2005-06       Impact factor: 2.502

10.  Evaluation of real-time QRS detection algorithms in variable contexts.

Authors:  F Portet; A I Hernández; G Carrault
Journal:  Med Biol Eng Comput       Date:  2005-05       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.