Discrimination in vitro between the acoustic emissions from Bjork-Shiley convexo-concave valves with and without a broken minor strut.

D K Walker1, L N Scotten.   

Abstract

A statistical pattern recognition technique is used to learn and recognise the frequency spectra of the closing sounds emitted by Bjork-Shiley convexo-concave heart valves, with and without fractured minor struts, when operating in vitro. The sounds are generated with test valves operating under a variety of conditions in a model left ventricle. It is found in the learning stage that the discriminant functions generated correctly classified almost all of the cases within the learning set. When applied to cases outside the learning set, including a recording of a clinically implanted valve, the functions correctly classify the valves. These preliminary results, for a limited number of valves, lead us to believe that the discriminant analysis of heart valve sounds is a promising noninvasive method for screening patients with implanted Bjork-Shiley convexo-concave valves.

Entities:  

Mesh:

Year:  1991        PMID: 1817206     DOI: 10.1007/BF02442314

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Outlet-strut fracture and disc embolization in 27-mm and smaller Björk-Shiley convexo-concave valves: historical overview and 3 case reports.

Authors:  C G Montero; R Burgos; J E Rodriguez; D Figuera
Journal:  Tex Heart Inst J       Date:  1989

2.  An in vitro study of prosthetic heart valve sound.

Authors:  L I Thulin; H Reul; M Giersiepen; C L Olin
Journal:  Scand J Thorac Cardiovasc Surg       Date:  1989

3.  A study of prosthetic heart valve sounds.

Authors:  H Köymen; B K Altay; Y Z Ider
Journal:  IEEE Trans Biomed Eng       Date:  1987-11       Impact factor: 4.538

4.  Strut fracture in the Björk-Shiley mitral valve prosthesis--two case reports.

Authors:  U Goerttler; R Kaiser-Martini
Journal:  Thorac Cardiovasc Surg       Date:  1984-10       Impact factor: 1.827

5.  Clinical performance of Bjork-Shiley mechanical heart valves: a perspective on outlet strut fractures in the 60 degrees and 70 degrees convexo-concave disc models.

Authors:  H E Scully; A Damle; B S Goldman; C Tong; J Azuma; L L Mickleborough; L Schwartz; R J Baird
Journal:  Can J Cardiol       Date:  1988-10       Impact factor: 5.223

6.  [Late outlet strut fracture of an aortic Björk-Shiley and embolization of the prosthetic disc].

Authors:  E Brochet; M A Bougis de Brux; P Assayag; Y Benacin; G Gamerman; C Guerot; P E Valère
Journal:  Arch Mal Coeur Vaiss       Date:  1988-09

7.  Acute failure of artificial heart valves.

Authors:  K Taylor
Journal:  BMJ       Date:  1988-10-22

8.  Mechanical failure of the Björk-Shiley valve. Updated follow-up and considerations on prophylactic rereplacement.

Authors:  D Lindblom; L Rodriguez; V O Björk
Journal:  J Thorac Cardiovasc Surg       Date:  1989-01       Impact factor: 5.209

9.  New generation tissue valves. Their in vitro function in the mitral position.

Authors:  D K Walker; L N Scotten; R T Brownlee
Journal:  J Thorac Cardiovasc Surg       Date:  1984-10       Impact factor: 5.209

Review 10.  Outlet strut fracture of the Björk-Shiley 60 degrees Convexo-Concave valve: current information and recommendations for patient care.

Authors:  L F Hiratzka; N T Kouchoukos; G L Grunkemeier; D C Miller; H E Scully; A S Wechsler
Journal:  J Am Coll Cardiol       Date:  1988-05       Impact factor: 24.094

View more
  1 in total

1.  Development and validation of implantable sensors for monitoring function of prosthetic heart valves: in vitro studies.

Authors:  C Lanning; R Shandas
Journal:  Med Biol Eng Comput       Date:  2003-07       Impact factor: 2.602