Outlet strut fracture of the Björk-Shiley 60 degrees Convexo-Concave valve: current information and recommendations for patient care.

L F Hiratzka1, N T Kouchoukos, G L Grunkemeier, D C Miller, H E Scully, A S Wechsler.   

Abstract

Mechanical failure of artificial heart valves can be a catastrophic event. The problem of outlet strut fracture of the Björk-Shiley 60 degrees Convexo-Concave tilting disc prosthesis has received much attention in the medical literature and generated both concern and confusion among patients and physicians. Analysis of current data from the manufacturer, as well as a review of the medical literature, suggests that the overall risk of outlet strut fracture is low and that elective explantation of a well functioning Björk-Shiley 60 degrees Convexo-Concave valve prosthesis is not warranted. Diagnostic features of outlet strut fracture can be seen with overpenetrated chest X-ray films so that diagnosis can be established promptly. Early operation to replace the fractured prosthesis is essential for patient survival.

Entities:  

Mesh:

Year:  1988        PMID: 3281994     DOI: 10.1016/s0735-1097(98)90075-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  7 in total

1.  Outlet-strut fracture and disc embolization in 27-mm and smaller Björk-Shiley convexo-concave valves: historical overview and 3 case reports.

Authors:  C G Montero; R Burgos; J E Rodriguez; D Figuera
Journal:  Tex Heart Inst J       Date:  1989

2.  Publicity about defects in artificial heart valves caused needless panic, doctor contends.

Authors:  D Spurgeon
Journal:  CMAJ       Date:  1991-11-15       Impact factor: 8.262

3.  Discrimination in vitro between the acoustic emissions from Bjork-Shiley convexo-concave valves with and without a broken minor strut.

Authors:  D K Walker; L N Scotten
Journal:  Med Biol Eng Comput       Date:  1991-09       Impact factor: 2.602

4.  Management of patients with Björk-Shiley prosthetic valves.

Authors:  T Treasure
Journal:  Br Heart J       Date:  1991-11

5.  Welder identity, weld date, and the risk of outlet strut fracture in Björk-Shiley convexo-concave valves: the Dutch cohort study.

Authors:  M Kallewaard; A Algra; Y van der Graaf
Journal:  Heart       Date:  1996-12       Impact factor: 5.994

6.  Psychological distress among recipients of Björk-Shiley convexo-concave valves: the impact of information.

Authors:  M Kallewaard; J Defauw; Y van der Graaf
Journal:  Heart       Date:  1997-12       Impact factor: 5.994

7.  Left ventricular dynamics after aortic valve replacement: a long-term, combined radionuclide angiographic and ultrasonographic study.

Authors:  C S Masotti; P Bonfranceschi; G Rusticali; F Rusticali; A Pierangeli
Journal:  Tex Heart Inst J       Date:  1992
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.