Development and validation of implantable sensors for monitoring function of prosthetic heart valves: in vitro studies.

C Lanning1, R Shandas.   

Abstract

The development of a 'smart' heart valve prosthesis, with the intrinsic ability to monitor thrombus formation, mechanical failure and local haemodynamics and to relay this information externally, would be of significant help to clinicians. The first step towards such a valve is development of the sensors and examination of whether sensor output provides predictive information on function. Custom-made piezo-electric sensors were mounted onto the housing of mechanical valves with various layers of simulated thrombus and bioprosthetic valves with normal and stiffened leaflets. Sensor output was examined using joint time-frequency analysis. Sensors were able to detect leaflet opening and closing with high fidelity for all types of valve. The frequency content of the closing sounds for the mechanical valves contained several peaks between 100 Hz and 10 kHz, whereas closing sounds for the bioprosthetic valve contained energy in a lower frequency range (<1 kHz). A frequency peak of 47 +/- 15 Hz was seen for the normal bioprosthetic valve; this peak increased to 115 +/- 12 Hz for the valve with visibly stiffened leaflets. Total low-frequency (80-3500 Hz) energy content diminished predictably with increasing levels of thrombus for the mechanical valves. Lastly, closing sound intensity correlated well with closing pressure dynamics (dp/dt) (y = 190x - 443; r = 0.90), indicating that the sensors also provide information on haemodynamics. These studies provide initial evidence regarding the use of embedded sensors to detect prosthetic valve function. Efforts to encapsulate these sensors with telemetry into a custom valve are currently underway.

Entities:  

Mesh:

Year:  2003        PMID: 12892364     DOI: 10.1007/bf02348084

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  12 in total

1.  Dynamic analysis of flutter in disk type mechanical heart valve prostheses.

Authors:  A A Prabhu; N H Hwang
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

2.  Vibrational analysis of bioprosthetic heart valve leaflets using numerical models: effects of leaflet stiffening, calcification, and perforation.

Authors:  M S Hamid; H N Sabbah; P D Stein
Journal:  Circ Res       Date:  1987-11       Impact factor: 17.367

3.  Detection of mechanical changes to prosthetic heart valves by spectral analysis of valve closing sounds.

Authors:  K J Reynolds; R O Stephen
Journal:  J Acoust Soc Am       Date:  1995-07       Impact factor: 1.840

4.  Comparison of spectral techniques for computer-assisted classification of spectra of heart sounds in patients with porcine bioprosthetic valves.

Authors:  L G Durand; Z Guo; H N Sabbah; P D Stein
Journal:  Med Biol Eng Comput       Date:  1993-05       Impact factor: 2.602

5.  An in vitro study of mechanical heart valve sound loudness.

Authors:  R L Erickson; L I Thulin; G J Richard
Journal:  J Heart Valve Dis       Date:  1994-05

6.  Tissue damage and calcification may be independent mechanisms of bioprosthetic heart valve failure.

Authors:  I Vesely; J E Barber; N B Ratliff
Journal:  J Heart Valve Dis       Date:  2001-07

7.  Acoustic classification of the state of artificial heart valves.

Authors:  T D Plemons; M Hovenga
Journal:  J Acoust Soc Am       Date:  1995-04       Impact factor: 1.840

8.  The complexity of external acoustic detection of defects in Björk-Shiley convexoconcave heart valves.

Authors:  B A de Mol; M E Cromheecke; J G Groen; G Faber; M S van der Heiden; L Ongkiehong
Journal:  Artif Organs       Date:  2001-01       Impact factor: 3.094

9.  Acoustic analysis of the closing sounds of implanted prosthetic heart valves.

Authors:  K J Reynolds; R O Stephen
Journal:  J Acoust Soc Am       Date:  1995-07       Impact factor: 1.840

10.  Acoustic characterization of mechanical valve condition and loading.

Authors:  A C Eberhardt; C E Chassaing; M A Ward; S J Lewandowski
Journal:  J Heart Valve Dis       Date:  1995-11
View more
  1 in total

1.  A Novel Sensorized Heart Valve Prosthesis: Preliminary In Vitro Evaluation.

Authors:  Emanuela Marcelli; Barbara Bortolani; Ivan Corazza; Laura Cercenelli
Journal:  Sensors (Basel)       Date:  2018-11-13       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.