Literature DB >> 22200017

Inferolateral entry point for c2 pedicle screw fixation in high cervical lesions.

Kwang Ho Lee1, Dong Ho Kang, Chul Hee Lee, Soo Hyun Hwang, In Sung Park, Jin Myung Jung.   

Abstract

OBJECTIVE: The purpose of this retrospective study was to evaluate the efficacy and safety of atlantoaxial stabilization using a new entry point for C2 pedicle screw fixation.
METHODS: Data were collected from 44 patients undergoing posterior C1 lateral mass screw and C2 screw fixation. The 20 cases were approached by the Harms entry point, 21 by the inferolateral point, and three by pars screw. The new inferolateral entry point of the C2 pedicle was located about 3-5 mm medial to the lateral border of the C2 lateral mass and 5-7 mm superior to the inferior border of the C2-3 facet joint. The screw was inserted at an angle 30° to 45° toward the midline in the transverse plane and 40° to 50° cephalad in the sagittal plane. Patients received followed-up with clinical examinations, radiographs and/or CT scans.
RESULTS: There were 28 males and 16 females. No neurological deterioration or vertebral artery injuries were observed. Five cases showed malpositioned screws (2.84%), with four of the screws showing cortical breaches of the transverse foramen. There were no clinical consequences for these five patients. One screw in the C1 lateral mass had a medial cortical breach. None of the screws were malpositioned in patients treated using the new entry point. There was a significant relationship between two group (p=0.036).
CONCLUSION: Posterior C1-2 screw fixation can be performed safely using the new inferolateral entry point for C2 pedicle screw fixation for the treatment of high cervical lesions.

Entities:  

Keywords:  Atlantoaxial fixation; C2 pedicle screw; Entry point

Year:  2011        PMID: 22200017      PMCID: PMC3243838          DOI: 10.3340/jkns.2011.50.4.341

Source DB:  PubMed          Journal:  J Korean Neurosurg Soc        ISSN: 1225-8245


  31 in total

1.  Anatomical considerations for subaxial (C2) pedicle screw placement: a radiographic study with computed tomography in 93 patients.

Authors:  Zachary A Smith; Simona Bistazzoni; Adebukoa Onibokun; Nan-Fu Chen; Marco Sassi; Larry T Khoo
Journal:  J Spinal Disord Tech       Date:  2010-05

2.  Comparison of the anatomical risk for vertebral artery injury associated with the C2-pedicle screw and atlantoaxial transarticular screw.

Authors:  Makoto Yoshida; Masashi Neo; Shunsuke Fujibayashi; Takashi Nakamura
Journal:  Spine (Phila Pa 1976)       Date:  2006-07-01       Impact factor: 3.468

3.  Occipitocervical arthrodesis using contoured plate fixation. An early report on a versatile fixation technique.

Authors:  M D Smith; P Anderson; M S Grady
Journal:  Spine (Phila Pa 1976)       Date:  1993-10-15       Impact factor: 3.468

4.  The anatomical suitability of the C1-2 complex for transarticular screw fixation.

Authors:  C G Paramore; C A Dickman; V K Sonntag
Journal:  J Neurosurg       Date:  1996-08       Impact factor: 5.115

5.  A radiographic computed tomography-based study to determine the ideal entry point, trajectory, and length for safe fixation using C-2 pars interarticularis screws.

Authors:  Daniel J Hoh; Charles Y Liu; Michael Y Wang
Journal:  J Neurosurg Spine       Date:  2010-06

Review 6.  Vertebral artery injury in C1-2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves. American Association of Neurological Surgeons/Congress of Neurological Surgeons.

Authors:  N M Wright; C Lauryssen
Journal:  J Neurosurg       Date:  1998-04       Impact factor: 5.115

7.  C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience.

Authors:  R W Haid; B R Subach; M R McLaughlin; G E Rodts; J B Wahlig
Journal:  Neurosurgery       Date:  2001-07       Impact factor: 4.654

8.  Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws.

Authors:  Scott L Parker; Matthew J McGirt; Giannina L Garcés-Ambrossi; Vivek A Mehta; Daniel M Sciubba; Timothy F Witham; Ziya L Gokaslan; Jean-Paul Wolinksy
Journal:  Neurosurgery       Date:  2009-05       Impact factor: 4.654

9.  Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis.

Authors:  C A Dickman; V K Sonntag
Journal:  Neurosurgery       Date:  1998-08       Impact factor: 4.654

10.  C1-C2 posterior cervical fusion: long-term evaluation of results and efficacy.

Authors:  T J Coyne; M G Fehlings; M C Wallace; M Bernstein; C H Tator
Journal:  Neurosurgery       Date:  1995-10       Impact factor: 4.654

View more
  4 in total

1.  CT analysis of C2 pedicles morphology and considerations of useful parameters for screwing.

Authors:  Mourad Ould-Slimane; Sebastien Le Pape; Julien Leroux; Emmanuel Foulongne; Camille Damade; Franck Dujardin; Fabrice Duparc
Journal:  Surg Radiol Anat       Date:  2013-11-16       Impact factor: 1.246

2.  C2 pars/pedicle screws in management of craniocervical and upper cervical instability.

Authors:  Mohammed Ahmed Eshra
Journal:  Asian Spine J       Date:  2014-04-08

3.  Surgical Morphometry of C1 and C2 Vertebrae: A Three-Dimensional Computed Tomography Analysis of 180 Chinese, Indian, and Malay Patients.

Authors:  Chee Kean Lee; Tiam Siong Tan; Chris Yin Wei Chan; Mun Keong Kwan
Journal:  Asian Spine J       Date:  2017-04-12

4.  Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Hossein Nayeb Aghaei; Shirzad Azhari; Sohrab Sadeghi; Ali Montazeri
Journal:  J Orthop Surg Res       Date:  2020-07-20       Impact factor: 2.359

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.