Biometry and intraocular lens power calculation.

Alexander C Lee1, Mujtaba A Qazi, Jay S Pepose.   

Abstract

PURPOSE OF REVIEW: Heightened patient expectations for precise postoperative refractive results have spurred the continued improvements in biometry and intraocular lens calculations. In order to meet these expectations, attention to proper patient selection, accurate keratometry and biometry, and appropriate intraocular lens power formula selection with optimized lens constants are required. The article reviews recent studies and advances in the field of biometry and intraocular lens power calculations. RECENT
FINDINGS: Several noncontact optical-based devices compare favorably, if not superiorly, to older ultrasonic biometric and keratometric techniques. With additional improvements in the internal acquisition algorithm, the new IOL Master software version 5 upgrade should lessen operator variability and further enhance signal acquisition. The modern Haigis-L and Holladay 2 formulas more accurately determine the position and the shape of the intraocular lens power prediction curve.
SUMMARY: Postoperative refractive results depend on the precision of multiple factors and measurements. The element with the highest variability and inaccuracy is, ultimately, going to determine the outcome. By understanding the advantages and limitations of the current technology, it is possible to consistently achieve highly accurate results.

Entities:  

Mesh:

Year:  2008        PMID: 18090891     DOI: 10.1097/ICU.0b013e3282f1c5ad

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  51 in total

1.  [Effect of applanation tonometry on precision of biometry measurements].

Authors:  T M Rabsilber; S Bueltmann; M P Holzer; G U Auffarth
Journal:  Ophthalmologe       Date:  2011-01       Impact factor: 1.059

2.  Anterior chamber depth in normal subjects by rotating scheimpflug imaging.

Authors:  Matthew T Feng; Michael W Belin; Renato Ambrósio; Satinder P S Grewal; Wang Yan; Mohamed S Shaheen; Charles McGhee; Naoyuki Maeda; Tobias H Neuhann; H Burkhard Dick; Saleh A Alageel; Andreas Steinmueller
Journal:  Saudi J Ophthalmol       Date:  2011-04-30

3.  Wide-field whole eye OCT system with demonstration of quantitative retinal curvature estimation.

Authors:  Ryan P McNabb; James Polans; Brenton Keller; Moseph Jackson-Atogi; Charlene L James; Robin R Vann; Joseph A Izatt; Anthony N Kuo
Journal:  Biomed Opt Express       Date:  2018-12-21       Impact factor: 3.732

4.  Ocular biometry through fully refocused steady-state magnetic resonance imaging sequence: reliability and agreement with the IOLMaster® 500.

Authors:  Lorenzo Ismael Perez-Sanchez; Julia Gutierrez-Vazquez; Maria Satrustegui-Lapetra; Francisco Ferreira-Manuel; Juan Jose Arevalo-Manso; Juan Jesus Gomez-Herrera; Juan Jose Criado-Alvarez
Journal:  Int Ophthalmol       Date:  2021-02-23       Impact factor: 2.031

5.  Hypermetropic shift following CTR implant.

Authors:  V S Gurunadh; M A Khan
Journal:  Med J Armed Forces India       Date:  2014-04

6.  Repeatability of Ophtha Top topography and comparison with IOL-Master and LenstarLS900 in cataract patients.

Authors:  Sha-Sha Yu; Hui Song; Xin Tang
Journal:  Int J Ophthalmol       Date:  2017-11-18       Impact factor: 1.779

7.  Repeatability assessment of anterior segment biometric measurements under accommodative and nonaccommodative conditions using an anterior segment OCT.

Authors:  Noelia Martínez-Albert; Jose J Esteve-Taboada; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2017-11-02       Impact factor: 3.117

8.  Comparison of ocular parameters of two biometric measurement devices in highly myopic eyes.

Authors:  Xiao-Xiao Guo; Ran You; Shan-Shan Li; Xiu-Fen Yang; Lu Zhao; Fan Zhang; Yan-Ling Wang; Xi Chen
Journal:  Int J Ophthalmol       Date:  2019-10-18       Impact factor: 1.779

9.  Novel Image-Based Analysis for Reduction of Clinician-Dependent Variability in Measurement of the Corneal Ulcer Size.

Authors:  Tapan P Patel; N Venkatesh Prajna; Sina Farsiu; Nita G Valikodath; Leslie M Niziol; Lakshey Dudeja; Kyeong Hwan Kim; Maria A Woodward
Journal:  Cornea       Date:  2018-03       Impact factor: 2.651

10.  Accuracy of axial length measurements from immersion B-scan ultrasonography in highly myopic eyes.

Authors:  Qing-Hua Yang; Bing Chen; Guang-Hua Peng; Zhao-Hui Li; Yi-Fei Huang
Journal:  Int J Ophthalmol       Date:  2014-06-18       Impact factor: 1.779

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.