Literature DB >> 18083529

The analysis of polystyrene and polystyrene aggregates into the mega dalton mass range by cryodetection MALDI TOF MS.

Alexander A Aksenov1, Mark E Bier.   

Abstract

Mass spectra of atactic polystyrene were collected into the mega-dalton mass range with a matrix-assisted laser desorption ionization time of flight (MALDI TOF) mass spectrometer, which incorporates a cryodetector comprised of an array of 16 superconducting tunnel junctions (STJ). The STJ cryodetector, theoretically, has no loss in signal response at any mass compared with the reduced signal found at high mass when using a conventional secondary-ionization detector. Since ion detection at high m/z is one of the fundamental limitations of mass spectrometry (MS), the cryodetector was used to explore the high m/z limit of the MALDI TOF technique for the analysis of two polymer types. Mass spectra were collected for polystyrene at Mn 170, 400, 900, and 2000 kDa and polymethyl methacrylate (PMMA) at Mn 62.6 kDa and 153.7 kDa. For polystyrene, the data showed a trend toward increased aggregation and charge state with mass. The Mn 2 MDa polystyrene data revealed a peak at m/z 2.2 MegaTh and a charge state analysis revealed that these ions were primarily polystyrene aggregates with a mass of approximately 4 MDa. This aggregate assignment was possible because the cryodetector response allows for the determination of a charge state up to about four. The contribution of each charge state for a selected peak can be determined in this fashion. This analysis revealed the preferential formation of doubly charged even-numbered aggregates over odd-numbered aggregates for high molecular mass polystyrene. A potential mechanism for the aggregation process for doubly charged species is discussed.

Entities:  

Year:  2007        PMID: 18083529     DOI: 10.1016/j.jasms.2007.10.019

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  23 in total

Review 1.  Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry.

Authors:  M Frank; S E Labov; G Westmacott; W H Benner
Journal:  Mass Spectrom Rev       Date:  1999 May-Aug       Impact factor: 10.946

2.  Single molecule detector for mass spectrometry with mass independent detection efficiency.

Authors:  D Twerenbold; D Gerber; D Gritti; Y Gonin; A Netuschill; F Rossel; D Schenker; J L Vuilleumier
Journal:  Proteomics       Date:  2001-01       Impact factor: 3.984

3.  New aspects in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry: a universal solvent-free sample preparation.

Authors:  S Trimpin; A Rouhanipour; R Az; H J Räder; K Müllen
Journal:  Rapid Commun Mass Spectrom       Date:  2001       Impact factor: 2.419

4.  MALDI ionization: the role of in-plume processes.

Authors:  R Knochenmuss; R Zenobi
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

5.  Solvent-free MALDI-MS for the analysis of biological samples via a mini-ball mill approach.

Authors:  Sarah Trimpin; Max L Deinzer
Journal:  J Am Soc Mass Spectrom       Date:  2005-04       Impact factor: 3.109

6.  Analysis of megadalton ions using cryodetection MALDI time-of-flight mass spectrometry.

Authors:  Ryan J Wenzel; Urs Matter; Lothar Schultheis; Renato Zenobi
Journal:  Anal Chem       Date:  2005-07-15       Impact factor: 6.986

7.  Immunoassays with direct mass spectrometric detection.

Authors:  Alexis Nazabal; Ryan J Wenzel; Renato Zenobi
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

8.  Evaluation of matrix-assisted laser desorption ionization mass spectrometry for polymer characterization.

Authors:  A M Belu; J M Desimone; R W Linton; G W Lange; R M Friedman
Journal:  J Am Soc Mass Spectrom       Date:  1996-01       Impact factor: 3.109

9.  Detection of High Molecular Weight Narrow Polydisperse Polymers up to 1.5 Million Daltons by MALDI Mass Spectrometry.

Authors:  D C Schriemer; L Li
Journal:  Anal Chem       Date:  1996-09-01       Impact factor: 6.986

10.  Importance of solubility in the sample preparation of poly(ethylene terephthalate) for MALDI TOFMS.

Authors:  Andrew J Hoteling; Thomas H Mourey; Kevin G Owens
Journal:  Anal Chem       Date:  2005-02-01       Impact factor: 6.986

View more
  10 in total

1.  Mass discrimination in high-mass MALDI-MS.

Authors:  Simon Weidmann; Gediminas Mikutis; Konstantin Barylyuk; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2013-07-09       Impact factor: 3.109

Review 2.  Correlated imaging--a grand challenge in chemical analysis.

Authors:  Rachel Masyuko; Eric J Lanni; Jonathan V Sweedler; Paul W Bohn
Journal:  Analyst       Date:  2013-02-21       Impact factor: 4.616

3.  Characterization of ZnO Nanoparticles using Superconducting Tunnel Junction Cryodetection Mass Spectrometry.

Authors:  Logan D Plath; Zongyu Wang; Jiajun Yan; Krzysztof Matyjaszewski; Mark E Bier
Journal:  J Am Soc Mass Spectrom       Date:  2017-04-18       Impact factor: 3.109

4.  Citric Acid Capped Iron Oxide Nanoparticles as an Effective MALDI Matrix for Polymers.

Authors:  Qiaoli Liang; Jennifer Sherwood; Thomas Macher; Joseph M Wilson; Yuping Bao; Carolyn J Cassady
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-06       Impact factor: 3.109

5.  Single Particle Analyzer of Mass: A Charge Detection Mass Spectrometer with a Multi-Detector Electrostatic Ion Trap.

Authors:  Andrew G Elliott; Samuel I Merenbloom; Satrajit Chakrabarty; Evan R Williams
Journal:  Int J Mass Spectrom       Date:  2017-01-15       Impact factor: 1.986

6.  Quantitative Imprint Mass Spectrometry Imaging of Endogenous Ceramides in Rat Brain Tissue with Kinetic Calibration.

Authors:  Qian Wu; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2020-04-16       Impact factor: 6.986

7.  Optimized Electrostatic Linear Ion Trap for Charge Detection Mass Spectrometry.

Authors:  Joanna A Hogan; Martin F Jarrold
Journal:  J Am Soc Mass Spectrom       Date:  2018-07-09       Impact factor: 3.109

8.  Acquiring Structural Information on Virus Particles with Charge Detection Mass Spectrometry.

Authors:  David Z Keifer; Tina Motwani; Carolyn M Teschke; Martin F Jarrold
Journal:  J Am Soc Mass Spectrom       Date:  2016-03-28       Impact factor: 3.109

9.  Dopamine-modified TiO2 monolith-assisted LDI MS imaging for simultaneous localization of small metabolites and lipids in mouse brain tissue with enhanced detection selectivity and sensitivity.

Authors:  Qian Wu; James L Chu; Stanislav S Rubakhin; Martha U Gillette; Jonathan V Sweedler
Journal:  Chem Sci       Date:  2017-03-21       Impact factor: 9.825

10.  On-Tissue Derivatization via Electrospray Deposition for Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging of Endogenous Fatty Acids in Rat Brain Tissues.

Authors:  Qian Wu; Troy J Comi; Bin Li; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2016-05-26       Impact factor: 6.986

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.