Literature DB >> 23836380

Mass discrimination in high-mass MALDI-MS.

Simon Weidmann1, Gediminas Mikutis, Konstantin Barylyuk, Renato Zenobi.   

Abstract

In high-mass matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), the accessible m/z range is limited by the detector used. Therefore, special high-mass detectors based on ion conversion dynodes (ICDs) have been developed. Recently, we have found that mass bias may exist when such ICD detectors are used [Weidmann et al., Anal. Chem. 85(6), 3425-3432 (2013)]. In this contribution, the mass-dependent response of an ICD detector was systematically studied, the response factors for proteins with molecular weights from 35.9 to 129.9 kDa were determined, and the reasons for mass bias were identified. Compared with commonly employed microchannel plate detectors, we found that the mass discrimination is less pronounced, although ions with higher masses are weakly favored when using an ICD detector. The relative response was found to depend on the laser power used for MALDI; low-mass ions are discriminated against with higher laser power. The effect of mutual ion suppression in dependence of the proteins used and their molar ratio is shown. Mixtures consisting of protein oligomers that only differ in mass show less mass discrimination than mixtures consisting of different proteins with similar masses. Furthermore, mass discrimination increases for molar ratios far from 1. Finally, we present clear guidelines that help to choose the experimental parameters such that the response measured matches the actual molar fraction as closely as possible.

Entities:  

Year:  2013        PMID: 23836380     DOI: 10.1007/s13361-013-0686-x

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  29 in total

Review 1.  Energy-sensitive cryogenic detectors for high-mass biomolecule mass spectrometry.

Authors:  M Frank; S E Labov; G Westmacott; W H Benner
Journal:  Mass Spectrom Rev       Date:  1999 May-Aug       Impact factor: 10.946

2.  The desorption process in MALDI.

Authors:  Klaus Dreisewerd
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

3.  MALDI ionization: the role of in-plume processes.

Authors:  R Knochenmuss; R Zenobi
Journal:  Chem Rev       Date:  2003-02       Impact factor: 60.622

4.  Designed to be stable: crystal structure of a consensus ankyrin repeat protein.

Authors:  Andreas Kohl; H Kaspar Binz; Patrik Forrer; Michael T Stumpp; Andreas Plückthun; Markus G Grütter
Journal:  Proc Natl Acad Sci U S A       Date:  2003-02-03       Impact factor: 11.205

5.  Compelling advantages of negative ion mode detection in high-mass MALDI-MS for homomeric protein complexes.

Authors:  Stefanie Mädler; Konstantin Barylyuk; Elisabetta Boeri Erba; Robert J Nieckarz; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2011-12-01       Impact factor: 3.109

6.  Rapid, sensitive analysis of protein mixtures by mass spectrometry.

Authors:  R C Beavis; B T Chait
Journal:  Proc Natl Acad Sci U S A       Date:  1990-09       Impact factor: 11.205

7.  Assessing the multimeric states of proteins: studies using laser desorption mass spectrometry.

Authors:  T B Farmer; R M Caprioli
Journal:  Biol Mass Spectrom       Date:  1991-12

8.  Analysis of enzymatic DNA sequencing reactions by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry.

Authors:  T A Shaler; Y Tan; J N Wickham; K J Wu; C H Becker
Journal:  Rapid Commun Mass Spectrom       Date:  1995       Impact factor: 2.419

9.  DNA sequencing by delayed extraction-matrix-assisted laser desorption/ionization time of flight mass spectrometry.

Authors:  M T Roskey; P Juhasz; I P Smirnov; E J Takach; S A Martin; L A Haff
Journal:  Proc Natl Acad Sci U S A       Date:  1996-05-14       Impact factor: 11.205

10.  High-affinity binders selected from designed ankyrin repeat protein libraries.

Authors:  H Kaspar Binz; Patrick Amstutz; Andreas Kohl; Michael T Stumpp; Christophe Briand; Patrik Forrer; Markus G Grütter; Andreas Plückthun
Journal:  Nat Biotechnol       Date:  2004-04-18       Impact factor: 54.908

View more
  5 in total

1.  Insight into Signal Response of Protein Ions in Native ESI-MS from the Analysis of Model Mixtures of Covalently Linked Protein Oligomers.

Authors:  Katharina Root; Yves Wittwer; Konstantin Barylyuk; Ulrike Anders; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2017-06-07       Impact factor: 3.109

2.  Citric Acid Capped Iron Oxide Nanoparticles as an Effective MALDI Matrix for Polymers.

Authors:  Qiaoli Liang; Jennifer Sherwood; Thomas Macher; Joseph M Wilson; Yuping Bao; Carolyn J Cassady
Journal:  J Am Soc Mass Spectrom       Date:  2016-12-06       Impact factor: 3.109

3.  High-mass MALDI-MS using ion conversion dynode detectors: influence of the conversion voltage on sensitivity and spectral quality.

Authors:  Simon Weidmann; Renato Zenobi
Journal:  J Am Soc Mass Spectrom       Date:  2014-03-29       Impact factor: 3.109

4.  Detection of large ions in time-of-flight mass spectrometry: effects of ion mass and acceleration voltage on microchannel plate detector response.

Authors:  Ranran Liu; Qiyao Li; Lloyd M Smith
Journal:  J Am Soc Mass Spectrom       Date:  2014-05-02       Impact factor: 3.109

5.  Extending the information content of the MALDI analysis of biological fluids via multi-million shot analysis.

Authors:  Maxim Tsypin; Senait Asmellash; Krista Meyer; Brandon Touchet; Heinrich Roder
Journal:  PLoS One       Date:  2019-12-09       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.