Literature DB >> 18068597

Vertical bone volume in the paramedian palate of adolescents: a computed tomography study.

Keith S King1, Ernest W Lam, M Gary Faulkner, Giseon Heo, Paul W Major.   

Abstract

INTRODUCTION: The paramedian palate (PP) has been used as a host site for orthodontic implant anchorage. Available bone and interference of adjacent tooth roots must be considered in identifying the most appropriate locations for implantations in the PP.
METHODS: Cone-beam computed tomography (CBCT) scans (NewTom QR-DVT 9000; QR s.r.l., Verona, Italy) were acquired in 183 orthodontic patients (ages, 10-19 years). Views of the PP region were reconstructed at increments posterior from the incisive foramen, and measurements of bone height were made in each reconstruction laterally from the midline to describe the PP.
RESULTS: At 4 mm posterior to the incisive foramen and 3 mm lateral to the midline, 93% of the male and 91% of the female subjects met the criterion for implantation. At 8 mm posterior to the incisive foramen and 3 mm lateral to the midline, 86% of the male and 58% of the female subjects met the criterion for implantation.
CONCLUSIONS: The PP contains several valid implant host sites in adolescent patients. At 4 mm distal and 3 mm lateral to the incisive foreman, 93.2% of the boys and 91.9% of the girls had sufficient vertical bone depth to host a 3-mm implant with little practical tooth interference. CBCT allows accurate assessment of the entire volume of a proposed implant site.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18068597     DOI: 10.1016/j.ajodo.2005.11.042

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  15 in total

Review 1.  Use of cone beam computed tomography in otolaryngologic treatments.

Authors:  Hamdi Cakli; Cemal Cingi; Yazgi Ay; Fatih Oghan; Torun Ozer; Ercan Kaya
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-27       Impact factor: 2.503

Review 2.  The current status of cone beam computed tomography imaging in orthodontics.

Authors:  S Kapila; R S Conley; W E Harrell
Journal:  Dentomaxillofac Radiol       Date:  2011-01       Impact factor: 2.419

Review 3.  CBCT in orthodontics: assessment of treatment outcomes and indications for its use.

Authors:  S D Kapila; J M Nervina
Journal:  Dentomaxillofac Radiol       Date:  2015       Impact factor: 2.419

Review 4.  Applications of Cone Beam Computed Tomography in Orthodontics: A Review.

Authors:  Aditya Tadinada; Alana Marczak; Sumit Yadav; Padma M Mukherjee
Journal:  Turk J Orthod       Date:  2016-09-01

5.  Evaluation of Palatal Bone Thickness and Its Relationship with Palatal Vault Depth for Mini-Implant Insertion Using Cone Beam Computed Tomography Images.

Authors:  Gholinia Faegheh; Negar Khosravifard; Dina Maleki; Sahar Khaje Hosseini
Journal:  Turk J Orthod       Date:  2022-06

6.  Evaluation of Dentoalveolar and Dentofacial Effects of a Mini-Screw-Anchored Pendulum Appliance in Maxillary Molar Distalization.

Authors:  Mümin Kırcalı; Alime Sema Yüksel
Journal:  Turk J Orthod       Date:  2018-12-01

7.  Evaluation of palatal bone density in adults and adolescents for application of skeletal anchorage devices.

Authors:  Seong Han; Mohamed Bayome; Jeongwon Lee; Yoon-Jin Lee; Hae-Hiang Song; Yoon-Ah Kook
Journal:  Angle Orthod       Date:  2011-11-11       Impact factor: 2.079

8.  Palatal bone thickness measured by palatal index method using cone-beam computed tomography in nonorthodontic patients for placement of mini-implants.

Authors:  W S Manjula; R V Murali; S Kishore Kumar; Faizal Tajir; K Mahalakshmi
Journal:  J Pharm Bioallied Sci       Date:  2015-04

9.  Effects of Skeletally Supported Anterior en Masse Retraction with Varied Lever Arm Lengths and Locations in Lingual Orthodontic Treatment: A 3D Finite Element Study.

Authors:  Mohammad Ghannam; Beste Kamiloğlu
Journal:  Biomed Res Int       Date:  2021-05-17       Impact factor: 3.411

10.  Comparative evaluation of molar distalization therapy using pendulum and distal screw appliances.

Authors:  Alberto Caprioglio; Alessandra Cafagna; Mattia Fontana; Mauro Cozzani
Journal:  Korean J Orthod       Date:  2015-07-24       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.