Literature DB >> 18060717

Reproducibility of the quantitative assessment of cartilage morphology and trabecular bone structure with magnetic resonance imaging at 7 T.

Jin Zuo1, Radu Bolbos, Kate Hammond, Xiaojuan Li, Sharmila Majumdar.   

Abstract

To assess the reproducibility of quantitative measurements of cartilage morphology and trabecular bone structure of the knee at 7 T, high-resolution sagittal spoiled gradient-echo images and high-resolution axial fully refocused steady-state free-precession (SSFP) images from six healthy volunteers were acquired with a 7-T scanner. The subjects were repositioned between repeated scans to test the reproducibility of the measurements. The reproducibility of each measurement was evaluated using the coefficient(s) of variation (CV). The computed CV were 1.13% and 1.55% for cartilage thickness and cartilage volume, respectively, and were 2.86%, 1.07%, 2.27% and 3.30% for apparent bone volume over total volume fraction (app.BV/TV), apparent trabecular number (app.Tb.N), apparent trabecular separation (app.Tb.Sp) and apparent trabecular thickness (app.Tb.Th), respectively. The results demonstrate that quantitative assessment of cartilage morphology and trabecular bone structure is reproducible at 7 T and motivates future musculoskeletal applications seeking the high-field strength's superior signal-to-noise ratio.

Entities:  

Mesh:

Year:  2007        PMID: 18060717      PMCID: PMC2838765          DOI: 10.1016/j.mri.2007.10.007

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  23 in total

Review 1.  Ultra-high-field MRI of the musculoskeletal system at 7.0T.

Authors:  Ravinder R Regatte; Mark E Schweitzer
Journal:  J Magn Reson Imaging       Date:  2007-02       Impact factor: 4.813

Review 2.  Quantitative MRI for the assessment of bone structure and function.

Authors:  Felix W Wehrli; Hee Kwon Song; Punam K Saha; Alexander C Wright
Journal:  NMR Biomed       Date:  2006-11       Impact factor: 4.044

3.  Sodium MRI of human articular cartilage in vivo.

Authors:  R Reddy; E K Insko; E A Noyszewski; R Dandora; J B Kneeland; J S Leigh
Journal:  Magn Reson Med       Date:  1998-05       Impact factor: 4.668

4.  Magnetic resonance imaging of normal and osteoarthritic trabecular bone structure in the human knee.

Authors:  Olivier Beuf; Srinka Ghosh; David C Newitt; Thomas M Link; Lynne Steinbach; Michael Ries; Nancy Lane; Sharmila Majumdar
Journal:  Arthritis Rheum       Date:  2002-02

Review 5.  Assessment of trabecular structure using high resolution magnetic resonance imaging.

Authors:  S Majumdar; H K Genant
Journal:  Stud Health Technol Inform       Date:  1997

6.  Longitudinal in vivo reproducibility of cartilage volume and surface in osteoarthritis of the knee.

Authors:  M H Brem; J Pauser; H Yoshioka; A Brenning; J Stratmann; F F Hennig; R Kikinis; J Duryea; C S Winalski; P Lang
Journal:  Skeletal Radiol       Date:  2007-01-12       Impact factor: 2.199

7.  Effects of salmon calcitonin on trabecular microarchitecture as determined by magnetic resonance imaging: results from the QUEST study.

Authors:  Charles H Chesnut; Sharmilla Majumdar; David C Newitt; Andrew Shields; Jan Van Pelt; Ellen Laschansky; Moise Azria; Audrey Kriegman; Melvin Olson; Erik F Eriksen; Linda Mindeholm
Journal:  J Bone Miner Res       Date:  2005-04-27       Impact factor: 6.741

8.  A pilot, two-year longitudinal study of the interrelationship between trabecular bone and articular cartilage in the osteoarthritic knee.

Authors:  Gabrielle Blumenkrantz; Colleen T Lindsey; Timothy C Dunn; Hua Jin; Michael D Ries; Thomas M Link; Lynne S Steinbach; Sharmila Majumdar
Journal:  Osteoarthritis Cartilage       Date:  2004-12       Impact factor: 6.576

9.  Parallel imaging of knee cartilage at 3 Tesla.

Authors:  Jin Zuo; Xiaojuan Li; Suchandrima Banerjee; Eric Han; Sharmila Majumdar
Journal:  J Magn Reson Imaging       Date:  2007-10       Impact factor: 4.813

10.  Steady-state diffusion-weighted imaging of in vivo knee cartilage.

Authors:  Karla L Miller; Brian A Hargreaves; Garry E Gold; John M Pauly
Journal:  Magn Reson Med       Date:  2004-02       Impact factor: 4.668

View more
  7 in total

1.  Simultaneous bilateral hip joint imaging at 7 Tesla using fast transmit B₁ shimming methods and multichannel transmission - a feasibility study.

Authors:  J Ellermann; U Goerke; P Morgan; K Ugurbil; J Tian; S Schmitter; T Vaughan; P-F Van De Moortele
Journal:  NMR Biomed       Date:  2012-02-07       Impact factor: 4.044

2.  High resolution morphologic imaging and T2 mapping of cartilage at 7 Tesla: comparison of cartilage repair patients and healthy controls.

Authors:  Gregory Chang; Ding Xia; Orrin Sherman; Eric Strauss; Laith Jazrawi; Michael P Recht; Ravinder R Regatte
Journal:  MAGMA       Date:  2013-05-09       Impact factor: 2.310

3.  Characterizing healthy and osteoarthritic knee cartilage on phase contrast CT with geometric texture features.

Authors:  Mahesh B Nagarajan; Paola Coan; Markus B Huber; Paul C Diemoz; Christian Glaser; Axel Wismüller
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-29

Review 4.  MRI assessment of bone structure and microarchitecture.

Authors:  Gregory Chang; Sean Boone; Dimitri Martel; Chamith S Rajapakse; Robert S Hallyburton; Mitch Valko; Stephen Honig; Ravinder R Regatte
Journal:  J Magn Reson Imaging       Date:  2017-02-06       Impact factor: 4.813

5.  Performance of the MRI-based virtual bone biopsy in the distal radius: serial reproducibility and reliability of structural and mechanical parameters in women representative of osteoporosis study populations.

Authors:  Shing Chun Benny Lam; Michael J Wald; Chamith S Rajapakse; Yinxiao Liu; Punam K Saha; Felix W Wehrli
Journal:  Bone       Date:  2011-07-19       Impact factor: 4.398

6.  Quantitative evaluation of subchondral bone microarchitecture in knee osteoarthritis using 3T MRI.

Authors:  Chenglei Liu; Chang Liu; Xvhua Ren; Liping Si; Hao Shen; Qian Wang; Weiwu Yao
Journal:  BMC Musculoskelet Disord       Date:  2017-11-28       Impact factor: 2.362

7.  Bone Structure Analysis of the Radius Using Ultrahigh Field (7T) MRI: Relevance of Technical Parameters and Comparison with 3T MRI and Radiography.

Authors:  Mohamed Jarraya; Rafael Heiss; Jeffrey Duryea; Armin M Nagel; John A Lynch; Ali Guermazi; Marc-André Weber; Andreas Arkudas; Raymund E Horch; Michael Uder; Frank W Roemer
Journal:  Diagnostics (Basel)       Date:  2021-01-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.