Literature DB >> 8125508

Magnetic resonance imaging can cause focal heating in a nonuniform phantom.

P L Davis1, C Shang, L Talagala, A W Pasculle.   

Abstract

To test if the radiofrequency fields of a magnetic resonance imager could cause focal heating, two cylindrical phantoms were made from a mixture of agar and saline. The first phantom was uniform; the second was nonuniform in that a narrow bridge of agar was produced. Both phantoms were exposed to high levels of radiofrequency power (140 W) at 63 MHz and the temperature rises were measured. In the uniform phantom, the temperature increased as the radius increased. In the bridge phantom, the narrow bridge heated three times greater than at the opposite uniform periphery, and over five times the average of the uniform phantom. This experiment demonstrates that the radiofrequency fields of magnetic resonance imagers can cause focal heating if the exposed object is nonuniform. Since nonuniformity is present in the human body, as the radiofrequency power of magnetic resonance imaging techniques increases, focal heating in patients is a concern.

Entities:  

Mesh:

Year:  1993        PMID: 8125508     DOI: 10.1109/10.250588

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  6 in total

1.  Optimized quadrature surface coil designs.

Authors:  Ananda Kumar; Paul A Bottomley
Journal:  MAGMA       Date:  2007-12-04       Impact factor: 2.310

2.  Calculation of radiofrequency electromagnetic fields and their effects in MRI of human subjects.

Authors:  Christopher M Collins; Zhangwei Wang
Journal:  Magn Reson Med       Date:  2011-03-04       Impact factor: 4.668

3.  Examining the effect of ions and proteins on the heat dissipation of iron oxide nanocrystals.

Authors:  V Kalidasan; X L Liu; Y Li; P J Sugumaran; A H Liu; L Ren; J Ding
Journal:  RSC Adv       Date:  2018-01-04       Impact factor: 4.036

4.  An anatomically realistic temperature phantom for radiofrequency heating measurements.

Authors:  Nadine N Graedel; Jonathan R Polimeni; Bastien Guerin; Borjan Gagoski; Giorgio Bonmassar; Lawrence L Wald
Journal:  Magn Reson Med       Date:  2014-02-18       Impact factor: 4.668

5.  Effects of Anatomical Differences on Electromagnetic Fields, SAR, and Temperature Change.

Authors:  Leeor Alon; Cem Murat Deniz; Giuseppe Carluccio; Ryan Brown; Daniel K Sodickson; Christopher M Collins
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2015-12-15       Impact factor: 1.176

6.  RF Safety Evaluation of a Breast Tissue Expander Device for MRI: Numerical Simulation and Experiment.

Authors:  Bu S Park; Amir Razjouyan; Leonardo M Angelone; Brent McCright; Sunder S Rajan
Journal:  IEEE Trans Electromagn Compat       Date:  2017-10       Impact factor: 2.006

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.