Literature DB >> 18053913

Image quality with multifocal intraocular lenses and the effect of pupil size: comparison of refractive and hybrid refractive-diffractive designs.

José M Artigas1, José L Menezo, Cristina Peris, Adelina Felipe, Manuel Díaz-Llopis.   

Abstract

PURPOSE: To analyze the image quality with a refractive and 2 hybrid refractive-diffractive multifocal intraocular lenses (IOLs) in vitro to determine the IOL modulation transfer function (MTF) following the EN-ISO international standard for distance and near vision and to study the IOLs' behavior with different pupil sizes.
SETTING: Fundación Oftalmológica del Mediterráneo, Valencia, Spain.
METHODS: This study evaluated 4 IOLs: the hybrid refractive-diffractive AcrySof ReSTOR SN60D3 (Alcon) and Tecnis ZM900 (AMO), the refractive ReZoom NXG (AMO), and the monofocal AcrySof SN60WF (Alcon). The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd.) using fast Fourier transform techniques. The artificial eye model simulated in vivo conditions of the anterior chamber and included an artificial cornea and physiological solution, in which the IOLs were positioned. The pupil sizes varied between 2.0 mm and 5.0 mm in steps of 0.5 mm.
RESULTS: For distance vision and small pupils (2.0 to 3.5 mm), the refractive IOL provided better image quality than the 2 hybrid IOLs. When the pupil was larger, the distance vision was similar with all IOLs. The 2 hybrid IOLs gave better image quality than the refractive IOL for near vision with any pupil size. With the refractive IOL and pupils smaller than 3.5 mm, near focusing did not occur, resulting in poor image quality. Of the hybrid IOLs, the AcrySof ReSTOR SN60D3 provided better distance image quality and the Tecnis ZM900 provided better near image quality.
CONCLUSIONS: The refractive IOL gave better image quality than the hybrid IOLs at distance and with small pupils. With pupils larger than 3.5 mm, the quality was similar. Hybrid IOLs gave significantly better image quality for near vision with all pupil sizes. AcrySof ReSTOR SN60D3 IOLs give better distance vision than Tecnis ZM900 IOLs; the latter gave better near vision. The reference monofocal IOL provided better distance images than any multifocal IOL with all pupil sizes.

Entities:  

Mesh:

Year:  2007        PMID: 18053913     DOI: 10.1016/j.jcrs.2007.07.035

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  25 in total

1.  In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony.

Authors:  Alberto Domínguez-Vicent; Jose Juan Esteve-Taboada; Antonio J Del Águila-Carrasco; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-16       Impact factor: 3.117

2.  All-distance visual acuity in eyes with a nontinted or a yellow-tinted diffractive multifocal intraocular lens.

Authors:  Ken Hayashi; Miki Masumoto; Hideyuki Hayashi
Journal:  Jpn J Ophthalmol       Date:  2009-03-31       Impact factor: 2.447

Review 3.  [Use of multifocal intraocular lenses and criteria for patient selection].

Authors:  T Kohnen; D Kook; G U Auffarth; V Derhartunian
Journal:  Ophthalmologe       Date:  2008-06       Impact factor: 1.059

4.  Temporal multiplexing with adaptive optics for simultaneous vision.

Authors:  Eleni Papadatou; Antonio J Del Águila-Carrasco; Iván Marín-Franch; Norberto López-Gil
Journal:  Biomed Opt Express       Date:  2016-09-15       Impact factor: 3.732

5.  In vitro optical performance of a new aberration-free intraocular lens.

Authors:  D Madrid-Costa; J Ruiz-Alcocer; T Ferrer-Blasco; S García-Lázaro; R Montés-Micó
Journal:  Eye (Lond)       Date:  2014-02-21       Impact factor: 3.775

6.  Implantation of refractive multifocal intraocular lens with a surface-embedded near section for cataract eyes complicated with a coexisting ocular pathology.

Authors:  M Ouchi; S Kinoshita
Journal:  Eye (Lond)       Date:  2015-03-06       Impact factor: 3.775

7.  Impact of contact lens zone geometry and ocular optics on bifocal retinal image quality.

Authors:  Arthur Bradley; Jayoung Nam; Renfeng Xu; Leslie Harman; Larry Thibos
Journal:  Ophthalmic Physiol Opt       Date:  2014-03-04       Impact factor: 3.117

8.  Wavefront analysis and modulation transfer function of three multifocal intraocular lenses.

Authors:  Marcony R Santhiago; Marcelo V Netto; Jackson Barreto; Beatriz A F Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Indian J Ophthalmol       Date:  2010 Mar-Apr       Impact factor: 1.848

9.  Visual Performance of Tecnis ZM900 Diffractive Multifocal IOL after 2500 Implants: A 3-Year Followup.

Authors:  Leonardo Akaishi; Rodrigo Vaz; Graziela Vilella; Rodrigo C Garcez; Patrick F Tzelikis
Journal:  J Ophthalmol       Date:  2010-10-05       Impact factor: 1.909

10.  A contralateral eye study comparing apodized diffractive and full diffractive lenses: wavefront analysis and distance and near uncorrected visual acuity.

Authors:  Marcony Rodrigues de Santhiago; Marcelo Vieira Netto; Jackson Barreto; Beatriz de Abreu Fiuza Gomes; Arthur Schaefer; Newton Kara-Junior
Journal:  Clinics (Sao Paulo)       Date:  2009       Impact factor: 2.365

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.