In vitro optical performance of a new aberration-free intraocular lens.

D Madrid-Costa1, J Ruiz-Alcocer1, T Ferrer-Blasco1, S García-Lázaro1, R Montés-Micó1.   

Abstract

PURPOSE: To assess the optical performance of the new EnVista intraocular lens (IOL).
MATERIALS AND METHODS: Four aspheric IOLs were evaluated; the new EnVista is one amoung them. This IOL, similarly to the Z-Flex HB and the Bi-Flex 1.8 667AB ones, has a neutral aspheric design, whereas the fourth IOL under test (AcrySof IQ IOL SN60WF) presents a negative spherical aberration (SA). The IOL's aberration patterns were measured in vitro, by setting them up on an optical bench. From these aberration-pattern data, the modulation transfer function (MTF), the average modulation values, and the points spread function (PSF) were calculated. Furthermore, in order to assess the potential optical quality that these IOLs would yield once they are implanted, an average corneal-aberration pattern was juxtaposed to the in-vitro profiles and the same parameters were calculated again.
RESULTS: For the IOL-only scenario (ie, without including the corneal factor), it was the EnVista IOL, which is aberration-free that showed the higher MTF, PSF values. This was followed by the other two aberration-free IOL models. However, when the effect of an average corneal pattern was also taken into consideration, the AcrySof IQ IOL SN60WF always outperformed the other neutral-asphericity IOLs.
CONCLUSIONS: The in-vitro optical performance of the EnVista IOL was good, but it decreases substantially in a whole-eye scenario, when the wavefront profile of an average cornea is added. Other designs with different degrees of SA should be considered for this IOL in order to surpass these results.

Entities:  

Mesh:

Year:  2014        PMID: 24556881      PMCID: PMC4017107          DOI: 10.1038/eye.2014.25

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  26 in total

1.  Optical aberrations of the human cornea as a function of age.

Authors:  A Guirao; M Redondo; P Artal
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2000-10       Impact factor: 2.129

2.  Phase-shifting schlieren: high-resolution quantitative schlieren that uses the phase-shifting technique principle.

Authors:  Luc Joannes; Frank Dubois; Jean-Claude Legros
Journal:  Appl Opt       Date:  2003-09-01       Impact factor: 1.980

3.  Correlation between optics quality of multifocal intraocular lenses and visual acuity: tolerance to modulation transfer function decay.

Authors:  Adelina Felipe; Francisco Pastor; José M Artigas; Amparo Diez-Ajenjo; Andrés Gené; José L Menezo
Journal:  J Cataract Refract Surg       Date:  2010-04       Impact factor: 3.351

Review 4.  Late in-the-bag intraocular lens dislocation: incidence, prevention, and management.

Authors:  Howard V Gimbel; Garry P Condon; Thomas Kohnen; Randall J Olson; Ioannis Halkiadakis
Journal:  J Cataract Refract Surg       Date:  2005-11       Impact factor: 3.351

Review 5.  Analysis of the possible benefits of aspheric intraocular lenses: review of the literature.

Authors:  Robert Montés-Micó; Teresa Ferrer-Blasco; Alejandro Cerviño
Journal:  J Cataract Refract Surg       Date:  2009-01       Impact factor: 3.351

6.  Three year prospective, randomized evaluation of intraocular lens implantation through 3.2 and 5.5 mm incisions.

Authors:  T Oshika; K Nagahara; S Yaguchi; K Emi; H Takenaka; S Tsuboi; F Yoshitomi; T Nagamoto; D Kurosaka
Journal:  J Cataract Refract Surg       Date:  1998-04       Impact factor: 3.351

7.  Effects of spherical aberration on visual acuity at different contrasts.

Authors:  Jing Li; Ying Xiong; Ningli Wang; Shiming Li; Yun Dai; Lixia Xue; Haoxin Zhao; Wenhan Jiang; Yudong Zhang
Journal:  J Cataract Refract Surg       Date:  2009-08       Impact factor: 3.351

8.  Prospective randomized comparison of phacoemulsification cataract surgery with a 3.2-mm vs a 5.5-mm sutureless incision.

Authors:  R J Olson; A S Crandall
Journal:  Am J Ophthalmol       Date:  1998-05       Impact factor: 5.258

Review 9.  Intraocular lens complications requiring removal or exchange.

Authors:  A N Carlson; W C Stewart; P C Tso
Journal:  Surv Ophthalmol       Date:  1998 Mar-Apr       Impact factor: 6.048

10.  Astigmatism and visual recovery after 'large incision' extracapsular cataract surgery and 'small' incisions for phakoemulsification.

Authors:  L Zheng; J C Merriam; M Zaider
Journal:  Trans Am Ophthalmol Soc       Date:  1997
View more
  1 in total

1.  Comparison of two types of visual quality analyzer for the measurement of high order aberrations.

Authors:  Jing Hao; Lin Li; Fang Tian; Hong Zhang
Journal:  Int J Ophthalmol       Date:  2016-02-18       Impact factor: 1.779

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.